Cisco Systems A03D600GA2 manual UCS DR UCSD7

Page 53

CONFIGURING the SERVER

You can choose a service listed in Table 28.

 

Table 28

UCS Computing Combined Support Service

 

 

 

 

 

Product ID (PID)

Service

On

Description

Level GSP

Site?

 

 

 

 

 

 

CON-NCF2-C220M3SFNCF2

No

CMB SPT SVC 24X7X2 UCS C220 M3 SFF

CON-NCF2P-C220M3SF

NCF2P

Yes

CMB SPT SVC 24X7X2OS UCS C220 M3 SFF

CON-NCF4P-C220M3SF

NCF4P

Yes

CMB SPT SVC 24X7X4OS UCS C220 M3 SFF

CON-NCF4S-C220M3SF

NCF4S

Yes

CMB SPT SVC 8X5X4OS UCS C220 M3 SFF

CON-NCFCS-C220M3SF

NCFCS

Yes

CMB SPT SVC 8X5XNBDOS UCS C220 M3 SFF

CON-NCFE-C220M3SF

NCFE

No

CMB SPT SVC 8X5X4 UCS C220 M3 SFF

CON-NCFP-C220M3SF

NCFP

No

CMB SPT SVC 24X7X4 UCS C220 M3 SFF

CON-NCFT-C220M3SF

NCFT

No

CMB SPT SVC 8X5XNBD UCS C220 M3 SFF

 

 

 

 

 

Unified Computing Drive Retention Service

With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.

Sophisticated data recovery techniques have made classified, proprietary, and confidential information vulnerable, even on malfunctioning disk drives. The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any potential liabilities. This service also enables you to comply with regulatory, local, and federal requirements.

If your company has a need to control confidential, classified, sensitive, or proprietary data, you might want to consider one of the Drive Retention Services listed in Table 29.

NOTE: Cisco does not offer a certified drive destruction service as part of this service.

Table 29 Drive Retention Service Options

Service Description

Service

Service

Service Level

Product ID (PID)

Program Name

Level GSP

 

 

 

 

 

 

 

 

SMARTnet for UCS

 

UCSD7

24x7x4 Onsite

CON-UCSD7-C220M3SF

Service with Drive

UCS DR

UCSD7

8x5xNBD Onsite

CON-UCSD5-C220M3SF

Retention

 

 

 

 

 

 

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

53

Image 53
Contents SAN JOSE, CA REV C.18 December 17 Spec SheetStep Step Verify Server SKUContents Page Overview Shows the Cisco UCS C220 M3 High-Density SFF Rack Server Chassis Front ViewChassis Rear View Shows the external features of the rear panelChassis One rack unit 1RU chassis Capabilities and Features Capability/Feature DescriptionCPU NICCapability/Feature Description Acpi Configuring the Server Cards, with 1 rail kit Verify Server SKUVerify the product ID PID of the server as shown in Table DDR3 Dimm Select CPUsProduct ID PID Freq Size Cores QPINumber GHz Support MHz1 Intel Xeon E5-26002 Select any one CPU listed in Table Approved Configurations CPU configurationsSelect two identical CPUs from any one of the rows of on CaveatsC220 M3 SFF Memory Organization Select MemoryDimm Select DIMMs and Memory MirroringDimm Options Memory Mirroring OptionA1, B1 A1,B1 C1,D1 A1,B1, C1 A2, B2, C2 A2,B2 C2,D2 CPU configuration with memory mirroringA1, B1 E1, F1 A1,B1 C1,D1 DPC Dimm Memory SpeedsConfiguring the Server Select RAID Configuration Available Embedded RAID Options Select RAID OptionsProduct ID PID PID Description RAID Controllers UCSC-RAID-ROM5UCSC-RAID-MZ-220 UCSC-RAID-11-C220Super Capacitor Option RAID Configuration Options not available for embedded RAIDAvailable PCIe RAID Controller Options Approved Configurations RAID4 RAID RAID1Caveats SSDs Select DrivesHDDs You can mix Sata and SAS drives Host Bus Adapters HBAs Select PCIe Option CardsNetwork Interface Cards NICs One PCIe RAID controller Approved Configurations No PCIe RAID controllerUCS Storage Accelerators Configuring the Server Choose Optional Twinax Cables Order Optional Network Card AccessoriesAvailable Twinax Cables Product ID PID PID Description Choose Optional SFP ModulesCaveats Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI Preinstalled do not change SFPCisco VIC 1225 Dual Port 10Gb SFP+ CNA Cisco VIC 1225T Dual Port 10GBaseT CNANetwork Card Connections Power Supply PIDs Order Power SupplyUCSC-PSU-450W UCSC-PSU-650WR2XX-DMYMPWRCORD Available Power Cords Product ID PID PID Description ImagesCAB-N5K6A-NA CAB-C13-CBNCAB-9K10A-EU CAB-9K10A-AUAvailable Power Cords Product ID PID PID Description Cable Management Arm Order Optional Reversible Cable Management ARMUCSC-CMA1 Cable Management Arm for C220 rack serversUCSX-TPM1-001 Trusted Platform Module Order a Trusted Platform Module OptionalTrusted Platform Module Product ID PID PID Description Secure Digital SD Card preloaded with software Order Cisco Flexible Flash SD Card Module OptionalSecond Secure Digital SD Card blank UCS-SD-16GOrder Optional USB 2.0 Drive See on page 57 for the location of the USB connectorUSB 2.0 Drive UCS-USBFLSH-S-4GBSuse Select Operating System and VALUE-ADDED SoftwareUCS Director BMCNexus 1000V for Hyper-V and vSphere Configuring the Server OS Media Product ID PID PID Description Select Operating System Media KITCisco SMARTnet for UCS Service Unified Computing Warranty, No ContractSMARTnet for UCS Product ID PID On Site? DescriptionUCS HW 24X7X4OS UCS C220 M3 SFF CON-UCW7-C220M3SFCON-UCW5-C220M3SF UC Plus 8X5XNBDOS UCS C220 M3 SFFService Product ID PID Level Description Site? Partner Support Service for UCSUnified Computing Combined Support Service GSPUCS DR UCSD7 UCSD7CON-UCWD7-C220M3SF UCWD7UCWD5 CON-UCWD5-C220M3SFRacks and Rack Options For more information about the PDU, see PDUs, PDU OptionsProduct ID PID PID Description RP208-30-2P-U-2 Zero RU PDU Supplemental Material Physical Layout CPUs and DIMMsCPU1 DPC or 2 DPC Memory Population RulesDPC DIMMs per Channel DPCPopulate the DIMMs for a CPU according to Table Dimm Population OrderRecommended Memory Configuration Supported Dimm Populations Supported Dimm Configurations Total DIMMsCPU TotalLow-Voltage Dimm Considerations RAID Details Available RAID configurations are shown in this sectionCPU Configurations Select one of the following Example Bios Screen for Oprom RAID Option ROM Oprom SettingsSerial Port Details Serial Port Female RJ-45 Connector PinoutUpgrade and Servicing-Related Parts CPU Removal and Installation pick n place Tool Set Motherboard Lithium BatteryDrive Blanking Panels Adding an Additional CPU with CPU heat sinkCPU Heat Sink Cleaning Kit Air Baffle Replacement KitRacks Cisco R42610 Rack Zero Rack Unit PDU PID = RP208-30-2P-U-2 PDUsN20-BKVM KVM Cable Product ID PID PID DescriptionKVM cable for B-Series Blade Server console port KVM CableMotherboard USB and SD Ports, and RAID Card Backup Location UCS C220 M3 Dimensions and Weight Parameter Value Dimensions and WeightPower Specifications Technical Specifications Output Class RSP1Input UCS C220 M3 Environmental Specifications Parameter Minimum Environmental SpecificationsCISPR24 Compliance RequirementsEN300386 KN24
Related manuals