Cisco Systems A03D600GA2 manual Dimensions and Weight, Power Specifications

Page 76

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Dimensions and Weight

Table 39 UCS C220 M3 Dimensions and Weight

Parameter

Value

 

 

Height

1.7 in. (4.32 cm)

Width

16.92 in.(43.0 cm)

Depth

28.5 in. (72.4cm)

Front Clearance

3 in. (76 mm)

Side Clearance

1 in. (25 mm)

Rear Clearance

6 in. (152 mm)

Weight

 

Maximum (8 HDDs, 2 CPUs, 16 DIMMs, 2 power supplies)

35.6 lbs (16.2 kg)

Minimum (1 HDD, 1 CPU, 1 DIMM, 1 power supply)

26.8 lbs (12.1 kg)

Bare (0 HDD, 0 CPU, 0 DIMM, 1 power supply)

22 lbs (10 kg)

 

 

Power Specifications

The general power specifications for the C220 M3 SFF server 450 W (AC) power supply are listed in Table 40.

Table 40 UCS C220 M3 SFF 450 W Power Supply Specifications

Description

Specification

 

 

AC input voltage

90 to 264 VAC self-ranging,

 

100 to 120 VAC nominal

 

200 to 240 VAC nominal

AC input frequency

Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)

Maximum AC input current

6.0 A peak at 100 VAC

 

3.0 A peak at 208 VAC

Maximum AC inrush current

11 A

Maximum output power for each

450 W

power supply

 

 

 

76

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

Image 76
Contents Spec Sheet SAN JOSE, CA REV C.18 December 17Step Verify Server SKU StepContents Page Overview Chassis Front View Shows the Cisco UCS C220 M3 High-Density SFF Rack ServerShows the external features of the rear panel Chassis Rear ViewCapabilities and Features Capability/Feature Description Chassis One rack unit 1RU chassisCPU NICCapability/Feature Description Acpi Configuring the Server Verify the product ID PID of the server as shown in Table Verify Server SKUCards, with 1 rail kit Select CPUs DDR3 DimmProduct ID PID Freq Size Cores QPINumber GHz Support MHz1 Intel Xeon E5-26002 Approved Configurations CPU configurations Select any one CPU listed in TableSelect two identical CPUs from any one of the rows of on CaveatsSelect Memory C220 M3 SFF Memory OrganizationSelect DIMMs and Memory Mirroring DimmDimm Options Memory Mirroring OptionCPU configuration with memory mirroring A1, B1 A1,B1 C1,D1 A1,B1, C1 A2, B2, C2 A2,B2 C2,D2A1, B1 E1, F1 A1,B1 C1,D1 Dimm Memory Speeds DPCConfiguring the Server Select RAID Configuration Select RAID Options Available Embedded RAID OptionsProduct ID PID PID Description RAID Controllers UCSC-RAID-ROM5UCSC-RAID-11-C220 UCSC-RAID-MZ-220Available PCIe RAID Controller Options RAID Configuration Options not available for embedded RAIDSuper Capacitor Option Approved Configurations RAID RAID1 RAID4Caveats HDDs Select DrivesSSDs You can mix Sata and SAS drives Network Interface Cards NICs Select PCIe Option CardsHost Bus Adapters HBAs UCS Storage Accelerators Approved Configurations No PCIe RAID controllerOne PCIe RAID controller Configuring the Server Order Optional Network Card Accessories Choose Optional Twinax CablesAvailable Twinax Cables Product ID PID PID Description Choose Optional SFP ModulesCaveats Preinstalled do not change SFP Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSICisco VIC 1225 Dual Port 10Gb SFP+ CNA Cisco VIC 1225T Dual Port 10GBaseT CNANetwork Card Connections Order Power Supply Power Supply PIDsUCSC-PSU-450W UCSC-PSU-650WAvailable Power Cords Product ID PID PID Description Images R2XX-DMYMPWRCORDCAB-N5K6A-NA CAB-C13-CBNCAB-9K10A-AU CAB-9K10A-EUAvailable Power Cords Product ID PID PID Description Order Optional Reversible Cable Management ARM Cable Management ArmUCSC-CMA1 Cable Management Arm for C220 rack serversTrusted Platform Module Product ID PID PID Description Order a Trusted Platform Module OptionalUCSX-TPM1-001 Trusted Platform Module Order Cisco Flexible Flash SD Card Module Optional Secure Digital SD Card preloaded with softwareSecond Secure Digital SD Card blank UCS-SD-16GSee on page 57 for the location of the USB connector Order Optional USB 2.0 DriveUSB 2.0 Drive UCS-USBFLSH-S-4GBSelect Operating System and VALUE-ADDED Software SuseNexus 1000V for Hyper-V and vSphere BMCUCS Director Configuring the Server Select Operating System Media KIT OS Media Product ID PID PID DescriptionUnified Computing Warranty, No Contract Cisco SMARTnet for UCS ServiceSMARTnet for UCS Product ID PID On Site? DescriptionCON-UCW7-C220M3SF UCS HW 24X7X4OS UCS C220 M3 SFFCON-UCW5-C220M3SF UC Plus 8X5XNBDOS UCS C220 M3 SFFPartner Support Service for UCS Service Product ID PID Level Description Site?Unified Computing Combined Support Service GSPUCSD7 UCS DR UCSD7UCWD7 CON-UCWD7-C220M3SFUCWD5 CON-UCWD5-C220M3SFRacks and Rack Options Product ID PID PID Description RP208-30-2P-U-2 Zero RU PDU PDU OptionsFor more information about the PDU, see PDUs, Supplemental Material CPUs and DIMMs Physical LayoutCPU1 Memory Population Rules DPC or 2 DPCDPC DIMMs per Channel DPCDimm Population Order Populate the DIMMs for a CPU according to TableRecommended Memory Configuration Supported Dimm Configurations Total DIMMs Supported Dimm PopulationsCPU TotalLow-Voltage Dimm Considerations CPU Configurations Select one of the following Available RAID configurations are shown in this sectionRAID Details RAID Option ROM Oprom Settings Example Bios Screen for OpromSerial Port Female RJ-45 Connector Pinout Serial Port DetailsUpgrade and Servicing-Related Parts Motherboard Lithium Battery CPU Removal and Installation pick n place Tool SetDrive Blanking Panels Adding an Additional CPU with CPU heat sinkAir Baffle Replacement Kit CPU Heat Sink Cleaning KitRacks Cisco R42610 Rack PDUs Zero Rack Unit PDU PID = RP208-30-2P-U-2KVM Cable Product ID PID PID Description N20-BKVMKVM cable for B-Series Blade Server console port KVM CableMotherboard USB and SD Ports, and RAID Card Backup Location Power Specifications Dimensions and WeightUCS C220 M3 Dimensions and Weight Parameter Value Technical Specifications Input Class RSP1Output Environmental Specifications UCS C220 M3 Environmental Specifications Parameter MinimumCompliance Requirements CISPR24EN300386 KN24
Related manuals
Manual 146 pages 4.56 Kb