Cisco Systems A03D600GA2 manual Memory Population Rules, DPC or 2 DPC, Dpc, DIMMs per Channel DPC

Page 60

SUPPLEMENTAL MATERIAL

Memory Population Rules

When considering the memory configuration of your server, you should consider the following items:

Each channel has two DIMM slots (for example, channel A = slots A1 and A2).

A channel can operate with one or two DIMMs installed.

If a channel has only one DIMM, populate slot 1 first (the blue slot).

When both CPUs are installed, populate the DIMM slots of each CPU identically.

Fill blue slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1

Fill black slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2

Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized.

Observe the DIMM mixing rules shown in Table 32

Table 32 DIMM Rules for C220 M3 Servers

DIMM Parameter

DIMMs in the Same Channel

DIMM in the Same Bank1

DIMM Capacity

RDIMM = 4, 8, or 16 GB

DIMMs in the same channel (for

 

example, A1 and A2) can have

 

different capacities.

LRDIMM = 32 GB

You cannot mix 32 GB LRDIMMs

 

with any RDIMM or UDIMM

UDIMM = 4 GB

You cannot mix 4 GB UDIMMs with

 

any RDIMM or LRIMM

DIMM Speed

 

For best performance, DIMMs in the same bank (for example, A1, B1, C1, D1) should have the same capacity.

You cannot mix 32 GB LRDIMMs with any RDIMM or UDIMM

You cannot mix 4 GB UDIMMs with any RDIMM or LRIMM

1866-, 1600-, or 1333-MHz2

DIMMs will run at the lowest speed

 

of the DIMMs/CPUs installed

DIMM Type

 

DIMMs will run at the lowest speed of the DIMMs/CPUs installed

RDIMMs, LRDIMMs, or UDIMMs

You cannot mix DIMM types in a

You cannot mix DIMM types in a bank

 

channel

 

 

 

 

 

1 DPC or 2 DPC

3 DPC

 

 

 

 

See Table 5 on page 20 for

Not supported

DIMMs per Channel (DPC)

valid LRDIMM and RDIMM 1 DPC and

 

 

2 DPC memory configurations

 

 

UDIMMs run at 1066 MHz at 1.35 V

 

 

and 1333 MHz at 1.5 V

 

 

 

 

Notes . . .

1.Although you can have different DIMM capacities in the same bank, this will result in less than optimal performance. For optimal performance, all DIMMs in the same bank should be identical.

2.Only 1866-, 1600-, and 1333-MHz DIMMs are currently available for the C220 M3 server.

60

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

Image 60
Contents Spec Sheet SAN JOSE, CA REV C.18 December 17Step Verify Server SKU StepContents Page Overview Chassis Front View Shows the Cisco UCS C220 M3 High-Density SFF Rack ServerShows the external features of the rear panel Chassis Rear ViewCapabilities and Features Capability/Feature Description Chassis One rack unit 1RU chassisCPU NICCapability/Feature Description Acpi Configuring the Server Verify Server SKU Verify the product ID PID of the server as shown in TableCards, with 1 rail kit Select CPUs DDR3 DimmProduct ID PID Freq Size Cores QPINumber GHz Support MHz1 Intel Xeon E5-26002 Approved Configurations CPU configurations Select any one CPU listed in TableSelect two identical CPUs from any one of the rows of on CaveatsSelect Memory C220 M3 SFF Memory OrganizationSelect DIMMs and Memory Mirroring DimmDimm Options Memory Mirroring OptionCPU configuration with memory mirroring A1, B1 A1,B1 C1,D1 A1,B1, C1 A2, B2, C2 A2,B2 C2,D2A1, B1 E1, F1 A1,B1 C1,D1 Dimm Memory Speeds DPCConfiguring the Server Select RAID Configuration Select RAID Options Available Embedded RAID OptionsProduct ID PID PID Description RAID Controllers UCSC-RAID-ROM5UCSC-RAID-11-C220 UCSC-RAID-MZ-220RAID Configuration Options not available for embedded RAID Available PCIe RAID Controller OptionsSuper Capacitor Option Approved Configurations RAID RAID1 RAID4Caveats Select Drives HDDsSSDs You can mix Sata and SAS drives Select PCIe Option Cards Network Interface Cards NICsHost Bus Adapters HBAs Approved Configurations No PCIe RAID controller UCS Storage AcceleratorsOne PCIe RAID controller Configuring the Server Order Optional Network Card Accessories Choose Optional Twinax CablesAvailable Twinax Cables Product ID PID PID Description Choose Optional SFP ModulesCaveats Preinstalled do not change SFP Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSICisco VIC 1225 Dual Port 10Gb SFP+ CNA Cisco VIC 1225T Dual Port 10GBaseT CNANetwork Card Connections Order Power Supply Power Supply PIDsUCSC-PSU-450W UCSC-PSU-650WAvailable Power Cords Product ID PID PID Description Images R2XX-DMYMPWRCORDCAB-N5K6A-NA CAB-C13-CBNCAB-9K10A-AU CAB-9K10A-EUAvailable Power Cords Product ID PID PID Description Order Optional Reversible Cable Management ARM Cable Management ArmUCSC-CMA1 Cable Management Arm for C220 rack serversOrder a Trusted Platform Module Optional Trusted Platform Module Product ID PID PID DescriptionUCSX-TPM1-001 Trusted Platform Module Order Cisco Flexible Flash SD Card Module Optional Secure Digital SD Card preloaded with softwareSecond Secure Digital SD Card blank UCS-SD-16GSee on page 57 for the location of the USB connector Order Optional USB 2.0 DriveUSB 2.0 Drive UCS-USBFLSH-S-4GBSelect Operating System and VALUE-ADDED Software SuseBMC Nexus 1000V for Hyper-V and vSphereUCS Director Configuring the Server Select Operating System Media KIT OS Media Product ID PID PID DescriptionUnified Computing Warranty, No Contract Cisco SMARTnet for UCS ServiceSMARTnet for UCS Product ID PID On Site? DescriptionCON-UCW7-C220M3SF UCS HW 24X7X4OS UCS C220 M3 SFFCON-UCW5-C220M3SF UC Plus 8X5XNBDOS UCS C220 M3 SFFPartner Support Service for UCS Service Product ID PID Level Description Site?Unified Computing Combined Support Service GSPUCSD7 UCS DR UCSD7UCWD7 CON-UCWD7-C220M3SFUCWD5 CON-UCWD5-C220M3SFRacks and Rack Options PDU Options Product ID PID PID Description RP208-30-2P-U-2 Zero RU PDUFor more information about the PDU, see PDUs, Supplemental Material CPUs and DIMMs Physical LayoutCPU1 Memory Population Rules DPC or 2 DPCDPC DIMMs per Channel DPCDimm Population Order Populate the DIMMs for a CPU according to TableRecommended Memory Configuration Supported Dimm Configurations Total DIMMs Supported Dimm PopulationsCPU TotalLow-Voltage Dimm Considerations Available RAID configurations are shown in this section CPU Configurations Select one of the followingRAID Details RAID Option ROM Oprom Settings Example Bios Screen for OpromSerial Port Female RJ-45 Connector Pinout Serial Port DetailsUpgrade and Servicing-Related Parts Motherboard Lithium Battery CPU Removal and Installation pick n place Tool SetDrive Blanking Panels Adding an Additional CPU with CPU heat sinkAir Baffle Replacement Kit CPU Heat Sink Cleaning KitRacks Cisco R42610 Rack PDUs Zero Rack Unit PDU PID = RP208-30-2P-U-2KVM Cable Product ID PID PID Description N20-BKVMKVM cable for B-Series Blade Server console port KVM CableMotherboard USB and SD Ports, and RAID Card Backup Location Dimensions and Weight Power SpecificationsUCS C220 M3 Dimensions and Weight Parameter Value Technical Specifications Class RSP1 InputOutput Environmental Specifications UCS C220 M3 Environmental Specifications Parameter MinimumCompliance Requirements CISPR24EN300386 KN24