Cisco Systems A03D600GA2 manual Select DIMMs and Memory Mirroring, Dimm Options

Page 17

CONFIGURING the SERVER

Select DIMMs and Memory Mirroring

Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in Table 4.

NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data.

Table 4 Available DDR3 DIMMs

Product ID (PID)

PID Description

Voltage

Ranks

/DIMM

 

 

 

 

 

 

 

 

 

DIMM Options1

 

 

 

 

UCS-ML-1X324RY-A

32 GB DDR3-1600-MHz LR DIMM/PC3-12800/4R/x4/1.35v

1.5/1.35 V2

4

UCS-MR-1X162RY-A

16 GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v

1.5/1.35 V2

2

UCS-MR-1X162RZ-A

16 GB DDR3-1866-MHz RDIMM PC3-14900/2R/x4/

1.5 V

2

UCS-MR-1X082RY-A

8

GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v

1.5/1.35 V2

2

UCS-MR-1X082RX-A3

8

GB DDR3-1333-MHz RDIMM/PC3-10600/2R/x4/1.35v

1.5/1.35 V2

2

UCS-MR-1X082RZ-A

8

GB DDR3-1866-MHz RDIMM/PC3-14900/2R/x4/

1.5 V

2

UCS-MR-1X041RY-A

4

GB DDR3-1600-MHz RDIMM/PC3-12800/1R/x4/1.35v

1.5/1.35 V2

1

UCS-MR-1X041RX-A3

4

GB DDR3-1333-MHz RDIMM/PC3-10600/1R/x4/1.35v

1.35 V

1

UCS-MU-1X042RE-A3

4

GB DDR3-1600-MHz ECC UDIMM/PC3-12800/2R/x8/1.35v

1.35 V

2

Memory Mirroring Option

 

 

N01-MMIRROR

Memory mirroring option

 

 

Notes . . .

1.1866-MHz DIMMs cannot be used with Intel Xeon E5-2600 CPUs

2.Dual voltage DIMM (operates at 1.5 V with BIOS is set for memory performance mode (default), or 1.35 V when BIOS is set for power-savings mode).

3.No longer shipping as of November, 2013

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

17

Image 17
Contents SAN JOSE, CA REV C.18 December 17 Spec SheetStep Step Verify Server SKUContents Page Overview Shows the Cisco UCS C220 M3 High-Density SFF Rack Server Chassis Front ViewChassis Rear View Shows the external features of the rear panelChassis One rack unit 1RU chassis Capabilities and Features Capability/Feature DescriptionCPU NICCapability/Feature Description Acpi Configuring the Server Cards, with 1 rail kit Verify Server SKUVerify the product ID PID of the server as shown in Table DDR3 Dimm Select CPUsProduct ID PID Freq Size Cores QPINumber GHz Support MHz1 Intel Xeon E5-26002 Select any one CPU listed in Table Approved Configurations CPU configurationsSelect two identical CPUs from any one of the rows of on CaveatsC220 M3 SFF Memory Organization Select MemoryDimm Select DIMMs and Memory MirroringDimm Options Memory Mirroring OptionA1, B1 A1,B1 C1,D1 A1,B1, C1 A2, B2, C2 A2,B2 C2,D2 CPU configuration with memory mirroringA1, B1 E1, F1 A1,B1 C1,D1 DPC Dimm Memory SpeedsConfiguring the Server Select RAID Configuration Available Embedded RAID Options Select RAID OptionsProduct ID PID PID Description RAID Controllers UCSC-RAID-ROM5UCSC-RAID-MZ-220 UCSC-RAID-11-C220Super Capacitor Option RAID Configuration Options not available for embedded RAIDAvailable PCIe RAID Controller Options Approved Configurations RAID4 RAID RAID1Caveats SSDs Select DrivesHDDs You can mix Sata and SAS drives Host Bus Adapters HBAs Select PCIe Option CardsNetwork Interface Cards NICs One PCIe RAID controller Approved Configurations No PCIe RAID controllerUCS Storage Accelerators Configuring the Server Choose Optional Twinax Cables Order Optional Network Card AccessoriesAvailable Twinax Cables Product ID PID PID Description Choose Optional SFP ModulesCaveats Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSI Preinstalled do not change SFPCisco VIC 1225 Dual Port 10Gb SFP+ CNA Cisco VIC 1225T Dual Port 10GBaseT CNANetwork Card Connections Power Supply PIDs Order Power SupplyUCSC-PSU-450W UCSC-PSU-650WR2XX-DMYMPWRCORD Available Power Cords Product ID PID PID Description ImagesCAB-N5K6A-NA CAB-C13-CBNCAB-9K10A-EU CAB-9K10A-AUAvailable Power Cords Product ID PID PID Description Cable Management Arm Order Optional Reversible Cable Management ARMUCSC-CMA1 Cable Management Arm for C220 rack serversUCSX-TPM1-001 Trusted Platform Module Order a Trusted Platform Module OptionalTrusted Platform Module Product ID PID PID Description Secure Digital SD Card preloaded with software Order Cisco Flexible Flash SD Card Module OptionalSecond Secure Digital SD Card blank UCS-SD-16GOrder Optional USB 2.0 Drive See on page 57 for the location of the USB connectorUSB 2.0 Drive UCS-USBFLSH-S-4GBSuse Select Operating System and VALUE-ADDED SoftwareUCS Director BMCNexus 1000V for Hyper-V and vSphere Configuring the Server OS Media Product ID PID PID Description Select Operating System Media KITCisco SMARTnet for UCS Service Unified Computing Warranty, No ContractSMARTnet for UCS Product ID PID On Site? DescriptionUCS HW 24X7X4OS UCS C220 M3 SFF CON-UCW7-C220M3SFCON-UCW5-C220M3SF UC Plus 8X5XNBDOS UCS C220 M3 SFFService Product ID PID Level Description Site? Partner Support Service for UCSUnified Computing Combined Support Service GSPUCS DR UCSD7 UCSD7CON-UCWD7-C220M3SF UCWD7UCWD5 CON-UCWD5-C220M3SFRacks and Rack Options For more information about the PDU, see PDUs, PDU OptionsProduct ID PID PID Description RP208-30-2P-U-2 Zero RU PDU Supplemental Material Physical Layout CPUs and DIMMsCPU1 DPC or 2 DPC Memory Population RulesDPC DIMMs per Channel DPCPopulate the DIMMs for a CPU according to Table Dimm Population OrderRecommended Memory Configuration Supported Dimm Populations Supported Dimm Configurations Total DIMMsCPU TotalLow-Voltage Dimm Considerations RAID Details Available RAID configurations are shown in this sectionCPU Configurations Select one of the following Example Bios Screen for Oprom RAID Option ROM Oprom SettingsSerial Port Details Serial Port Female RJ-45 Connector PinoutUpgrade and Servicing-Related Parts CPU Removal and Installation pick n place Tool Set Motherboard Lithium BatteryDrive Blanking Panels Adding an Additional CPU with CPU heat sinkCPU Heat Sink Cleaning Kit Air Baffle Replacement KitRacks Cisco R42610 Rack Zero Rack Unit PDU PID = RP208-30-2P-U-2 PDUsN20-BKVM KVM Cable Product ID PID PID DescriptionKVM cable for B-Series Blade Server console port KVM CableMotherboard USB and SD Ports, and RAID Card Backup Location UCS C220 M3 Dimensions and Weight Parameter Value Dimensions and WeightPower Specifications Technical Specifications Output Class RSP1Input UCS C220 M3 Environmental Specifications Parameter Minimum Environmental SpecificationsCISPR24 Compliance RequirementsEN300386 KN24
Related manuals