Cisco Systems A03D600GA2 manual UCS Storage Accelerators, One PCIe RAID controller

Page 32

CONFIGURING the SERVER

Table 11 Available PCIe Option Cards (continued)

Product ID (PID)

PID Description

Card Height

 

 

 

N2XX-AQPCI05

Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA

Half

UCSC-PCIE-Q2672

Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics

Half

UCSC-PCIE-E16002

Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics

Half

 

 

UCS Storage Accelerators

 

 

 

 

UCSC-F-FIO-3000M

Cisco UCS 3.0 TB MLC Fusion ioDrive2 for C-Series Servers

Full

UCSC-F-FIO-1205M

Cisco UCS 1205 GB MLC Fusion ioDrive2 for C-Series Servers

Half

UCSC-F-FIO-785M

Cisco UCS 785 GB MLC Fusion ioDrive2 for C-Series Servers

Half

UCSC-F-FIO-365M

Cisco UCS 365GB MLC Fusion ioDrive2 for C-Series Servers

Half

 

 

 

Approved Configurations

(1)No PCIe RAID controller

If you did not choose a PCIe RAID controller (for example, you are using embedded RAID or a mezzanine RAID controller), you can select up to one PCie option card (for 1-CPU systems) or two PCie option cards (for 2-CPU systems) listed in Table 11 on page 31.

(2)One PCIe RAID controller

If you selected a PCIe RAID controller, you can select none of the optional PCIe cards (for

1-CPU systems) or one of the optional PCIe cards (for 2-CPU systems) listed in Table 11 on page 31.

NOTE: If a PCIe RAID controller card is installed, any optional PCIe card you select will be installed in the full-height slot. RAID controllers are always installed in the half-height slot.

Caveats

For 1-CPU systems:

Only the full-height PCIe slot (slot 1) is supported

Neither PCIe slot 2 nor the mezzanine card slot are supported

Only a single VIC card (the Cisco VIC 1225 PCIe card) is supported and must be installed in slot 1 (the full-height slot).

If any of the Fusion ioDrive2 cards are installed, they must be plugged into slot 1. Note that only the Cisco UCS 3.0 TB MLC Fusion ioDrive2 card is full-height; all other Fusion ioDrive2 cards are half-height and therefore may need an adapter to hold them securely in the full-height slot.

For 2-CPU systems:

32

Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)

Image 32
Contents Spec Sheet SAN JOSE, CA REV C.18 December 17Step Verify Server SKU StepContents Page Overview Chassis Front View Shows the Cisco UCS C220 M3 High-Density SFF Rack ServerShows the external features of the rear panel Chassis Rear ViewCapabilities and Features Capability/Feature Description Chassis One rack unit 1RU chassisCPU NICCapability/Feature Description Acpi Configuring the Server Cards, with 1 rail kit Verify Server SKUVerify the product ID PID of the server as shown in Table Select CPUs DDR3 DimmProduct ID PID Freq Size Cores QPINumber GHz Support MHz1 Intel Xeon E5-26002 Approved Configurations CPU configurations Select any one CPU listed in TableSelect two identical CPUs from any one of the rows of on CaveatsSelect Memory C220 M3 SFF Memory OrganizationSelect DIMMs and Memory Mirroring DimmDimm Options Memory Mirroring OptionCPU configuration with memory mirroring A1, B1 A1,B1 C1,D1 A1,B1, C1 A2, B2, C2 A2,B2 C2,D2A1, B1 E1, F1 A1,B1 C1,D1 Dimm Memory Speeds DPCConfiguring the Server Select RAID Configuration Select RAID Options Available Embedded RAID OptionsProduct ID PID PID Description RAID Controllers UCSC-RAID-ROM5UCSC-RAID-11-C220 UCSC-RAID-MZ-220Super Capacitor Option RAID Configuration Options not available for embedded RAIDAvailable PCIe RAID Controller Options Approved Configurations RAID RAID1 RAID4Caveats SSDs Select DrivesHDDs You can mix Sata and SAS drives Host Bus Adapters HBAs Select PCIe Option CardsNetwork Interface Cards NICs One PCIe RAID controller Approved Configurations No PCIe RAID controllerUCS Storage Accelerators Configuring the Server Order Optional Network Card Accessories Choose Optional Twinax CablesAvailable Twinax Cables Product ID PID PID Description Choose Optional SFP ModulesCaveats Preinstalled do not change SFP Broadcom 57712 Dual Port 10Gb SFP+ w/TOE iSCSICisco VIC 1225 Dual Port 10Gb SFP+ CNA Cisco VIC 1225T Dual Port 10GBaseT CNANetwork Card Connections Order Power Supply Power Supply PIDsUCSC-PSU-450W UCSC-PSU-650WAvailable Power Cords Product ID PID PID Description Images R2XX-DMYMPWRCORDCAB-N5K6A-NA CAB-C13-CBNCAB-9K10A-AU CAB-9K10A-EUAvailable Power Cords Product ID PID PID Description Order Optional Reversible Cable Management ARM Cable Management ArmUCSC-CMA1 Cable Management Arm for C220 rack serversUCSX-TPM1-001 Trusted Platform Module Order a Trusted Platform Module OptionalTrusted Platform Module Product ID PID PID Description Order Cisco Flexible Flash SD Card Module Optional Secure Digital SD Card preloaded with softwareSecond Secure Digital SD Card blank UCS-SD-16GSee on page 57 for the location of the USB connector Order Optional USB 2.0 DriveUSB 2.0 Drive UCS-USBFLSH-S-4GBSelect Operating System and VALUE-ADDED Software SuseUCS Director BMCNexus 1000V for Hyper-V and vSphere Configuring the Server Select Operating System Media KIT OS Media Product ID PID PID DescriptionUnified Computing Warranty, No Contract Cisco SMARTnet for UCS ServiceSMARTnet for UCS Product ID PID On Site? DescriptionCON-UCW7-C220M3SF UCS HW 24X7X4OS UCS C220 M3 SFFCON-UCW5-C220M3SF UC Plus 8X5XNBDOS UCS C220 M3 SFFPartner Support Service for UCS Service Product ID PID Level Description Site?Unified Computing Combined Support Service GSPUCSD7 UCS DR UCSD7UCWD7 CON-UCWD7-C220M3SFUCWD5 CON-UCWD5-C220M3SFRacks and Rack Options For more information about the PDU, see PDUs, PDU OptionsProduct ID PID PID Description RP208-30-2P-U-2 Zero RU PDU Supplemental Material CPUs and DIMMs Physical LayoutCPU1 Memory Population Rules DPC or 2 DPCDPC DIMMs per Channel DPCDimm Population Order Populate the DIMMs for a CPU according to TableRecommended Memory Configuration Supported Dimm Configurations Total DIMMs Supported Dimm PopulationsCPU TotalLow-Voltage Dimm Considerations RAID Details Available RAID configurations are shown in this sectionCPU Configurations Select one of the following RAID Option ROM Oprom Settings Example Bios Screen for OpromSerial Port Female RJ-45 Connector Pinout Serial Port DetailsUpgrade and Servicing-Related Parts Motherboard Lithium Battery CPU Removal and Installation pick n place Tool SetDrive Blanking Panels Adding an Additional CPU with CPU heat sinkAir Baffle Replacement Kit CPU Heat Sink Cleaning KitRacks Cisco R42610 Rack PDUs Zero Rack Unit PDU PID = RP208-30-2P-U-2KVM Cable Product ID PID PID Description N20-BKVMKVM cable for B-Series Blade Server console port KVM CableMotherboard USB and SD Ports, and RAID Card Backup Location UCS C220 M3 Dimensions and Weight Parameter Value Dimensions and WeightPower Specifications Technical Specifications Output Class RSP1Input Environmental Specifications UCS C220 M3 Environmental Specifications Parameter MinimumCompliance Requirements CISPR24EN300386 KN24