Environmental Monitoring and Reporting Functions
Voltage readings:
+3.30 V measured at +3.28 V
+1.50 V measured at +1.49 V
+2.50 V measured at +2.48 V
+1.80 V measured at +1.78 V
+1.20 V measured at +1.19 V VDD_CPU measured at +1.27 V VDD_MEM measured at +2.48 V VTT measured at +1.24 V
+3.45 V measured at +3.49 V
Fans:
NPE Fan 1 is working
NPE Fan 2 is working
NPE Fan 3 is working
LC Fan 1 is working
LC Fan 2 is working
LC Fan 3 is working
Envm stats saved 2 time(s) since reload
Fan Failures
When the system power is on, the Cisco uBR7225VXR router fans should be operational. The system continues to operate if a fan fails; however, if the air temperature exceeds a defined threshold, the system controller displays warning messages on the console terminal and, if the temperature exceeds the shutdown threshold, it shuts down the system.
If the system does shut down because the temperature exceeded the shutdown threshold, the system displays the following message on console screen and in environment display when the system restarts:
Queued messages:
For complete descriptions and instructions for the environmental monitor commands, refer to the following documents:
Cisco IOS CMTS Command Reference Guide at the following URL:
http://www.cisco.com/en/US/docs/interfaces_modules/cable/line_cards/installation/guide/mcxxfru.htm l
Cisco IOS CMTS Cable Software Configuration Guide at the following URL:
http://www.cisco.com/web/techdoc/cable/Config/Sw_conf.html
Cisco IOS Configuration Fundamentals Command Reference at the following URL:
http://www.cisco.com/en/US/docs/ios/12_2/configfun/command/reference/ffun_r.html
Cisco uBR7225VXR Universal Broadband Router Hardware Installation Guide
|
| |
|