Chapter 4 Connecting the Cisco uBR7225VXR Router to the Cable Headend
Measuring the Downstream RF Signal
These two sections describe the procedures necessary to use a spectrum analyzer. You may also use a signal level meter that has the ability to measure the average power level of digitally modulated carriers, as well as a QAM analyzer. Some instruments to perform these measurements include:
•Acterna
•Agilent 8591C, N1776A, 2010 or 3010 (http://www.tm.agilent.com)
•Sunrise Telecom
•Telsey
•Trilithic 860DSP w/Option QA1 (http://www.trilithic.com)
If you complete these measurements using one of the previously mentioned options, your downstream signal can be verified as correctly configured and it can assist you with troubleshooting your network later on.
If you want to measure the downstream RF signal using the spectrum analyzer channel power option, proceed to the following section, “Measuring the Downstream RF Signal Using the Channel Power Option on a Spectrum Analyzer.” If you want to measure the downstream RF signal using CATV mode, proceed to the “Measuring the Downstream RF Signal Using CATV Mode on a Spectrum Analyzer” section on page
Measuring the Downstream RF Signal Using the Channel Power Option on a Spectrum Analyzer
The following sections describe how to measure the downstream RF signal using the channel power option on a spectrum analyzer:
•Measuring the Downstream IF Signal at the Cisco uBR7225VXR Router, page
•Measuring the Downstream RF Signal at the Upconverter Output, page
Measuring the Downstream IF Signal at the Cisco uBR7225VXR Router
Note Refer to the user guide that accompanied your spectrum analyzer to determine the exact steps required to use your analyzer to perform these measurements.
Step 1 Connect a spectrum analyzer to the downstream connector on a Cisco cable interface line card installed in a Cisco uBR7225VXR router.
Step 2 Turn the power switch on the spectrum analyzer to the ON position.
Step 3 Set the spectrum analyzer to view the downstream intermediate frequency (IF) signal with a center frequency of 44 MHz for a North American headend or 36.125 MHz for a European headend.
Step 4 Set the span to 10 MHz. Your analyzer should display a signal similar to the one shown in Figure
Cisco uBR7225VXR Universal Broadband Router Hardware Installation Guide
|
|
| |
|
|