Chapter 1 Cisco uBR7225VXR Overview

Cisco uBR7225VXR Universal Broadband Router

Cisco uBR7225VXR Router Chassis

The Cisco uBR7225VXR router chassis has:

Two slots for cable interface cards

One slot for a network processing engine

The front of the Cisco uBR7225VXR chassis provides access to two cable interface line cards. See Figure 1-1.

The rear of the Cisco uBR7225VXR provides access to the network processing engine and up to two power supplies. See Figure 1-2.

A fully configured Cisco uBR7225VXR router can operate with only one installed power supply; however, a second, optional power supply of the same type provides hot-swappable, load-sharing, and redundant power. In a chassis using two power supplies, if one power supply fails or is removed, the redundant power supply immediately takes over the router’s power requirements and maintains normal operation without interruption.

The power supply has the router’s main power switch and an AC-input power receptacle. Mounting holes for a ground lug are located on the far right side on the rear of the chassis, to provide a chassis ground connection for ESD-preventive equipment. See Figure 3-13 on page 3-16.

Note Figure 1-2shows the rear of a Cisco uBR7225VXR router configured with two 300W AC-input power supplies.

Caution If you are using two power supplies, make sure that each one is plugged into a separate branch circuit.

A fully loaded router, with two installed power supplies (300 W) and all chassis slots filled, weighs approximately 48 pounds (21.8 kg). For clearance requirements and rack-mount installation considerations, refer to the “Site Environment” section on page 2-5.

Figure 1-1 Cisco uBR7225VXR RouterFront View

 

 

1

 

 

 

 

 

 

 

 

 

S

US0

US1

US2

US3

US4

US5

 

 

uBR - MC16U

DS0

 

L

 

 

 

-

 

 

 

 

RF

 

O

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

uBR7225-VXR

 

 

 

 

 

 

 

 

uBR - MC28U

DS0

DS1

S

US0

US1

US2

US3

US4

US5

US6

US7

 

 

-

-

L

 

RF

RF

O

 

 

 

 

 

 

 

 

 

 

270489

T

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

1

Cable interface line card slot 1

2

Cable interface line card slot 2

Cisco uBR7225VXR Universal Broadband Router Hardware Installation Guide

 

OL-17309-02

1-3

 

 

 

Image 15
Contents Text Part Number OL-17309-02 Americas HeadquartersPage N T E N T S AC Power Measuring the Downstream RF Signal at the Upconverter Output Maintaining the Cisco uBR7225VXR Router Coaxial Cables C-1 Viii Revision Date Change Summary PrefaceDocument Revision History Document ObjectivesAudience Document OrganizationChapter Title Description Appendix G, Site Log Document ConventionsObtaining Documentation and Submitting a Service Request Cisco uBR7225VXR Universal Broadband Router Cisco uBR7225VXR OverviewOL-17309-02 Cable interface line card slot Cisco uBR7225VXR Router ChassisCard Slot and Logical Interface Numbering Cisco uBR7225VXR Network Interface OverviewCisco uBR7255VXR Chassis and Cable Interface Line Cards MAC-Layer AddressBasic Internet Access Services Supported System Configurations OverviewTwo-Way HFC Cable Network Example IP Telephony Services VPN ServicesHFC Telco ReturnNetwork Processing Engine Hardware Component DescriptionsNPE Comparisons Cisco Cable Interface Line Cards Power Supplies Fan Trays Cisco uBR7225VXR AC-Input Power SupplyCisco uBR7225VXR Fan Tray Internal Airflow-Top View Subchassis and Midplane Cisco uBR7225VXR ChassisTop Back CompactFlash DiskCisco uBR7225VXR Overview Hardware Component Descriptions OL-17309-02 Safety Recommendations InstallationLifting the Cisco uBR7225VXR Router Safely Lifting the Chassis Cisco uBR7246 Router Shown Safety with ElectricityPreventing Electrostatic Discharge Damage AC Power Site RequirementsSite Environment Site Configuration Maintaining Normal Operation General PrecautionsSpecification Minimum Maximum Power Considerations Required Network InformationBefore You Begin Rack-Mount and Cable-Management Kit Installation ToolsShipping Container Contents Equipment Required to Verify Your Plant’s RF SetupTwo-Way Data and VoIP Provisioning the Cable HeadendHeadend Certification Diplex FiltersReceivers DHCP, DNS, TFTP, and TD Servers Dial-Up/Remote Access ServersAuthentication, Authorization, and Accounting Servers VoIP Gateways and GatekeepersVoIP Sgcp Pass-Through Interference Considerations Headend WiringEquipment Racks 17.32 23.875 21.875 Task Verified By Date Site Preparation ChecklistTask Verified By Date Component ChecklistsCisco uBR7225VXR Router Installation Checklist Installing the Cisco uBR7225VXR RouterCisco uBR7225VXR Router Chassis Rack-Mounting Options Typical 4-Post Equipment Rack Posts and Mounting Strips Rack-mount bracket Cable-Management Bracket Requirements Installing the Chassis in a Telco-Type RackRack-mount bracket Cable-management bracket Installing Rack-Mount Brackets on the Rear of the Chassis Installing the Brackets on the ChassisInstalling Rack-Mount Brackets on the Front of the Chassis Installing Rack-Mount Brackets in the Middle of the Chassis Installing the Chassis in the Rack OL-17309-02 OL-17309-02 Cabling Console and Auxiliary Port Connection Equipment Connecting Cable Interface Line Card CablesConsole Port Signals Auxiliary Port SignalsPin Signal Direction Description Protective Grounding Connecting PowerConnecting to the AC-Input Power Supply 14 Connecting AC-Input Power Powering On the Cisco uBR7225VXR RouterConfiguring the Interfaces OL-17309-02 Connecting the Cisco uBR7225VXR Router to the Cable Headend Two-Way Data Headend Architecture RF and Digital Data Overview One-Way Data Headend ArchitectureConnecting and Configuring the Downstream Measuring the Downstream RF SignalInstalling and Configuring the Upconverter Page Viewing the Downstream if Signal on a Spectrum Analyzer Measuring the Downstream RF Signal at the Upconverter Output Overloaded Spectrum Analyzer Input Page OL-17309-02 OL-17309-02 OL-17309-02 OL-17309-02 OL-17309-02 OL-17309-02 OL-17309-02 OL-17309-02 Channel Bandwidth Cisco MC11 Fpga Connecting and Configuring the UpstreamConnecting the Upstream to the Optical Receiver Docsis Specification30 km Fiber node Milliwatt Measure +10 dBmV at this point Testing the Upstream ConfigurationOptical receiver Downstream Optical +10 dBmV Receiver +13 dBmV Attenuator Measuring the Upstream RF Signal Using a Spectrum Analyzer Measuring the Upstream RF SignalOL-17309-02 OL-17309-02 29 Analyzing the Upstream RF Signal-64-Byte Data Packets Analyzing the Upstream RF Signal30 Analyzing the Upstream RF Signal-1500-Byte Data Packets OL-17309-02 Using the Zero-Span Method with Adjacent Upstream Channels Center Frequency Minimum ResolutionSymbol Rate +/-1/2 Symbol Rate Bandwidth OL-17309-02 35 Vector Signal Analyzer Plot of Upstream Data Burst OL-17309-02 OL-17309-02 OL-17309-02 39 Preamble Amplitude Before Center Frequency Adjustment 41 Original Preamble Viewed with Accelerated Sweep Time OL-17309-02 Connecting the Cisco uBR7225VXR Router to the Cable Headend OL-17309-02 Connecting the Cisco uBR7225VXR Router to the Cable Headend Configuring the Digital Signal OL-17309-02 OL-17309-02 Online Insertion and Removal Maintaining the Cisco uBR7225VXR RouterEnvironmental Monitoring Environmental Monitoring and Reporting FunctionsParameter High Warning High Critical Shutdown Reporting FunctionsRouter# show environment Temperature ranges and values are subject to change Fan Failures Troubleshooting OverviewProviding Information Troubleshooting Problem Solving with Subsystems Problem Solving with SubsystemsIdentifying Startup Problems Cooling Subsystem Power SubsystemProcessor Subsystem Troubleshooting the Network Processing EngineTroubleshooting Cable Interface Line Cards Other Troubleshooting Information Websites Verifying the Downstream SignalTroubleshooting Verifying the Downstream Signal Description Specification Cisco uBR7225VXR Router SpecificationsBroadband Routers at the following URL Channel Qpsk Raw RF SpecificationsChannel Symbol Rate Raw Data Rate Nominal Data Bandwidth, MHz Msym/sec Mbps Rate, MbpsDocsis 1.0 Transmission Characteristics Downstream RF Channel Transmission CharacteristicsParameter Value Upstream RF Channel Transmission Characteristics Docsis 1.1 Transmission Characteristics EuroDOCSIS Transmission Characteristics Downstream RF Channel Transmission Characteristics Upstream RF Channel Transmission Characteristics Electrical Input and Output Parameter Value OL-17309-02 Coaxial Cables Cable SpecificationsIdentifying an RJ-45 Rollover Cable Console and Auxiliary Port Cables and PinoutsRJ-45-to-DB-9 Console Port Cables and PinoutsFast Ethernet Port Cables and Pinouts Auxiliary Port Cables and PinoutsIdentifying an RJ-45 Crossover Cable Identifying an RJ-45 Straight-Through Cable RJ-45 PinRJ-45 Pin Description Figure C-5 Duplex SC Cable Connector Fiber-Optic Cables and ConnectorsAbout Wiring Standards Industry-Standard Wiring PlansOptical Fiber Color Codes TIA/EIA Standards InformationPosition Color Pair Number Wire Number Solid Color Stripe Color Pin Number Telephone Wire Color CodesPair Number Wire Number Solid Color Stripe Color Pin Number White Blue Green Red Orange Black Yellow Pair Number Wire Number Solid Color Stripe ColorOL-17309-02 Http//developer.apple.com Http//atxnetworks.com Frequency Allocation TablesB1, G D1, K Standards ComparisonsNtsc Cable Television Channels and Relative Frequencies Freq MHz Carrier Visual Aural Table E-4 Freq MHz Carrier Visual Aural Table E-4 Ntsc M Cable Television Frequencies for Japan Table E-5 Japanese Channel Assignments Bandwidth Visual Carrier Aural Carrier PAL/SECAM Cable Television Channels and Relative FrequenciesChannel Channel Bandwidth Visual Carrier Aural Carrier Number MHz Table E-6 OL-17309-02 Manufacturers for Headend Provisioning Requirements North American Channel PlansManufacturer Website or Phone Number Products/Model Agilent Agilent 89411A European Channel Plans Agilent Agilent 8591C Tektronix 2715 Sunrise Telecom AT2000R Site Log Initials Symbols GL-2 GL-3 GL-4 GL-5 GL-6 D E IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8
Related manuals