![](/images/new-backgrounds/1194943/19494375x1.webp)
Chapter 2 Preparing the Cisco uBR7225VXR Router for Installation
Site Requirements
To provide airflow through the Cisco uBR7225VXR router, cooling air is drawn in through the air intake vent on the right side of the chassis (when viewing the router from the front) and is exhausted through the left side of the chassis. Keep the right and left sides of the chassis clear of obstructions and away from the exhaust of other equipment.
Note The Cisco uBR7225VXR router is suitable for installation in Network Telecommunication Facilities and locations where the National Electrical Code (NEC) applies. The Cisco uBR7225VXR router is not intended for installation in outside plant (OSP) locations.
Table | Specifications for Operating and Nonoperating Environments |
| |
|
|
|
|
Specification |
| Minimum | Maximum |
|
|
| |
Temperature, ambient operating | 32oF (0oC) | 104oF (40oC) | |
Temperature, ambient nonoperating and storage | 149oF (65oC) | ||
Humidity, ambient (noncondensing) operating | 10% | 90% | |
|
|
| |
Humidity, ambient (noncondensing) nonoperating | 5% | 95% | |
and storage |
|
|
|
|
|
| |
Altitude, operating and nonoperating | Sea level | 10,000 feet (3,050 meters) | |
|
|
| |
Vibration, operating | 5 to 200 Hz, 0.5 g (1 oct./min.) | – | |
|
|
| |
Vibration, nonoperating | 5 to 200 Hz, 1 g (1 oct./min.) | – | |
|
| 200 to 500 Hz, 2 g (1 oct./min.) |
|
|
|
|
|
Site Configuration: Maintaining Normal Operation
Planning a proper location for the Cisco uBR7225VXR universal broadband router and the layout of your equipment rack or wiring closet are essential for successful system operation. Equipment placed too close together or inadequately ventilated can cause system overtemperature conditions. In addition, chassis panels made inaccessible by poor equipment placement can make system maintenance difficult. Following are precautions that can help avoid problems during installation and ongoing operation.
General Precautions
Follow these general precautions when planning your equipment locations and connections:
•Use the show environment command regularly to check the internal system status. The environmental monitor continually checks the interior chassis environment; it provides warnings for high temperature and maximum and minimum voltages and creates reports on any occurrences. If warning messages are displayed, take immediate action to identify the cause and correct the problem.
•We recommend keeping the Cisco uBR7225VXR router off the floor and out of any area that tends to collect dust, excessive condensation, or water.
•Follow ESD prevention procedures to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent equipment failure.
Cisco uBR7225VXR Universal Broadband Router Hardware Installation Guide
|
| |
|