C o n f i g u r a t i o n V i e w s
Error Alarms
Allows you to enable or disable detection of Error Alarms. Possible menu selections are: Enable and Disable.
Error Threshold
Displays the threshold value for the percentage of errors per good packet that may occur within the Timebase before generating an error alarm. This value is
Error Source
This area of the Repeater Configuration view provides a series of buttons that let you select the types of errors to include in the error sum. The selectable error types are as described below.
CRC
Packets with bad Cyclical Redundancy Checks.
Runts
A packet that is one byte less than the standard Ethernet frame of 64 bytes (not including preamble).
OOW_Colls
Collisions out of the standard window due to a network problem.
Alignment
Misaligned packets detected.
E t h e r n e t B a s e d C o n f i g u r a t i o n
No_Resource
The number of times the module ran out of resources (i.e., lack of buffer space) and could not accept packets.
Giants
Packets received that exceed 1518 bytes (not including preamble).
Ethernet Based Configuration
Access: From the Chassis Icon, select Ethernet Based
Configuration.
This view provides port configuration information for GPIM models. This view also shares fields with the Fast Ethernet Configuration View (page 54) and the shared fields are covered there. The fields below detail the device specific information found with this view.
Auto Negotiate Mode
Indicates whether
Remote Auto Signal
Indicates whether the remote end of the link is operating in
S p e c t r u m E n t e r p r i s e M a n a g e r | Page 58 | S m a r t S w i t c h 6 0 0 0 |