Cabletron Systems SSIM-H2-02 manual Declaration of Conformity Addendum, Iii

Page 4

iii

Declaration of Conformity

Addendum

Application of Council Directive(s): 89/336/EEC 73/23/EEC

Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way

PO Box 5005

Rochester, NH 03867

European Representative Name: Mr. J. Solari

European Representative Address: Cabletron Systems Limited

Nexus House,

Newbury Business Park

London Road, Newbury

Berkshire RG13 2PZ, England

Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC

EC Directive 73/23/EEC EN 55022

EN 50082-1 EN 60950

Equipment Type/Environment: Networking Equipment, for use in a Commercial or Light Industrial Environment.

We the undersigned, hereby declare, under our sole responsibility, that the equipment packaged with this notice conforms to the above directives.

Manufacturer

Mr. Ronald Fotino

Full Name

Principal Compliance Engineer

Title

Rochester, NH, USA

Location

Legal Representative in Europe

Mr. J. Solari

Full Name

Managing Director - E.M.E.A.

Title

Newbury, Berkshire, England Location

Notice

Image 4
Contents Page Order Number 9032962-01 OC-7063 v .1 Vcci Notice FCC NoticeIndustry Canada Notice Iii Declaration of Conformity AddendumApplication of Council Directives 89/336/EEC 73/23/EEC Page Table of Contents Statistics List of Figures ViiList of Tables ViiiSSIM-H2-02 Switch SmartStack Interface Module IntroductionFeature Description This makes it possible to configure the device Part of the LAN switchSnmp is supported via the host processor Processor on the SmartStack STS16-20RMMIB Support FEUplink MIBInstallation Package ContentsInstallation Procedure Hardware Installation Removing the Expansion Slot CoverSoftware Installation Tftp DownloadSerial Download From the main menu, select Download→ UploadCabling LEDsPower-On Self Test Configuration Default ConfigurationConfiguration Introduction Ports, Port Groups and VLANsVirtual Port Restriction TS Virtual Ports and Vlan TaggingRing Number Restriction Source Routed Transparent Bridging SRT Mode Source Routed Switching SRS Operation ModeBridging Modes Source Routed Bridging SRB Mode Ethernet CRF in SRB Bridging ModeNetwork Scenarios Redundant Connections to Fast Ethernet NetworkPreventing Frame Duplication Preventing Frame Looping Frame LoopingSpanning Tree Configuration Broken Ethernet CloudRedundant Connections to Fast Ethernet Network Page Technical Background STP Cost Modification General Guidelines Main Switch Menu Navigating Within the MenusConfiguration Overview Vlan Configuration Port Configuration TS PortsBRF Configuration Local Vlan Port ConfigurationVirtual Port Configuration StatusDisplay only. Shows the current status of the port Address Demand Aging LevelDefault Display only. Shows the current status of the virtual portYou can use only one value as MTU 1558 001Vlan Tagging Mode FC ModificationAddress Aging Time RIF Not Learn IntervalIP Conversion Status Frame Conversion ConfigurationIP Conversion Parameters Change Default SR IP Ethernet FormatSets the format of IP frames on Ethernet Snap Frame in the Ieee 802.3 format with SnapEnable IP Fragmentation Novell Conversion StatusExplorer Frames Type TR MAC Address for IP MulticastsNovell Conversion Parameters Change Novell Frames ConversionNovell Token Ring Format Novell Ethernet FormatNetBios Conversion Status NetBios Conversion Parameters ChangeNetBios Frames Conversion IPX Address TranslationNetBios Token Ring Format NetBios Ethernet FormatSNA Conversion Status SNA Conversion Parameters ChangeSNA Ethernet Format Sets the format of SNA frames on EthernetOther Frames w/SNAP Conversion Status Other Frames w/SNAP Conversion Parameters ChangeOther Frames w/SNAP Frames Conversion Other Frames w/SNAP Token Ring FormatOther Frames w/o Snap Conversion Status Other Frames w/SNAP Ethernet FormatOther Frames w/o Snap Conversion Parameters Change Other Frames w/o Snap Frames ConversionOther Frames w/o Snap Token Ring Format Other Frames w/o Snap Ethernet FormatDual Home FEP Addresses Configuration Page Statistics Statistics Menu Port Status Port Statistics General StatisticsDiscarded Frames Table Filtered by Address Filter Table Filtered by Dsap FilterLocally Filtered Table Blocked Virtual PortTraffic Counters Error Counters Virtual Port Statistics Discarded Frames StatisticsVirtual Port State Frames ForwardedNetBios Inbound Translation errorsOther w/SNAP Other w/o SnapOutbound Translation Errors Outbound No TranslationFragmentation Error Generic w/o SnapGetting in Touch with Technical Support Your email addressPage Appendix A. Abbreviations Service Access Point Sub-Network Access ProtocolSource Route Switching Translational SwitchIndex Index-1Local Vlan port configuration Index-2710001816