Cabletron Systems MICROMMAC-22T, 42T manual Set, Built-In commands

Page 93

LOCAL MANAGEMENT

next

This command shows the next leaf in a path.

pwd

This command displays the full path name of the directory in which you are working.

set

This command lets you set the value of a managed object.

su

This command lets you change your community name.

tree

This command displays an entire MIB for a device.

whoami

This command displays community name and access privileges to the MIB.

Built-In commands

Built-In commands allow you to access and manage network devices connected to the device. Commands are described as follows:

arp

This command lets you access the Address Resolution Protocol (arp) cache to view cache data delete entries, or add a static route.

defroute

This command lets you set the default IP route to a device through a specified interface.

netstat

This command lets you display general network statistics for a managed device.

4-39

Image 93
Contents Page Iii FCC Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Contents Local Management TroubleshootingSaved System Messages Viewing Power UP Diagnostic Tests Chapter Introduction Contents OverviewMicroMMAC-T Overview Telnet MicroMMAC-T FeaturesSpeed Fault Protection Cable Signal PolarityActive TCU Ports Local ManagementCabletron’s Distributed LAN Monitor Mode Ring Speed SwitchFlash Eeprom Lanview LEDsCOM Port Applications Reset ButtonLCD and LCD Display Button MIB SupportRmon MIB Support Rmon MIB RFC 1271/1513 SupportGroup Subgroup Section Stackable Capabilities Typical Stackable Configuration BRIDGING/ROUTING CapabilitiesRemote Management Capabilities 1 SNA/WAN IntegrationTelnet Capabilities BRIMsGetting Help Recommended ReadingMicroMMAC-T Ports/Cables Cable SpecificationsAttenuation and Impedance UTP Cable SpecificationsUTP Voice Grade and Category 3 Specifications Frequency Impedance AttenuationType 3 Media Filters Maximum Lobe LengthsMaximum Number of Stations UTP Maximum Lobe LengthsSTP Cable Specifications STP Cable SpecificationsTypes Frequency Impedance Attenuation STP Maximum Lobe Lengths Maximum Trunk LengthsSTP Cable Type Ring Speed Mbps STP Maximum Drive DistanceAttenuation Mixed Cable TypesMultimode Fiber Optic Cable Specifications Cable Type Attenuation Maximum Drive DistanceSingle Mode Fiber Optic Cable Specifications Single Mode Fiber Optic Cable SpecificationsFiber Optic Budget Temperature Cable RECOMMENDATIONS/TROUBLESHOOTINGCrosstalk NoiseCOM 1/COM 2 Ports COM Port SpecificationsUPS Tpim SpecificationsSlip TPIM-T1TPIM-T1 Pinouts TPIM-T2TPIM-T4 Pinouts TPIM-F2TPIM-F2 Specifications TPIM-F3Parameter Typical Worst Case Value Budget Parameter Typical Minimum MaximumREQUIREMENTS/SPECIFICATIONS Power Supply Requirements General SpecificationsOutput Min. Load Max. Load Max Power Environmental RequirementsSafety ServicePhysical Attaching the Strain Relief Bracket Unpacking the MicroMMAC-TRack-Mounting the MicroMMAC-T Installing the MicroMMAC-TWall-Mounting the MicroMMAC-T Installing of Rack-Mount BracketsWall-Mounting the MicroMMAC-T Free-Standing Installation Connecting to a Power SourceResetting the MICROMMAC-T Setting the Ring Speed To reset the MicroMMAC-TTo change the ring speed To restore MicroMMAC-T parameters to the factory defaults Setting the Nvram SwitchRJ45 Plug MIC Connector Connecting Lobe Port CablingAt TCU At device port RJ45 Plug10. UTP Configuration Example 11. STP Configuration Example To attach a lobe segment to a MicroMMAC-T network portInstalling Tpim Modules Signal RJ45 DB9 Ring-In Ring-OutPinout Cross-Reference for TPIMs Setting Phantom and RI/RO Switches To install a TPIM, perform the following steps Tpim InstallationTo connect a TPIM-T1 to a Twisted Pair Segment Connecting STP SegmentsTo connect a segment to a TPIM-T2/-T4 Connecting Twisted Pair Segments16. The TPIM-T2/-T4 Connecting Fiber Optic Link Segments17. The TPIM-F2/-F3 To connect a fiber optic link segment to the TPIM-F2 /-F3To check MicroMMAC-T installation Checking the InstallationUse Local Management to Do the Following Management Terminal RequirementsManagement Terminal Setup Parameters Attaching the Management TerminalTo attach a management terminal to the MicroMMAC-T Modem Cable Configuration and Setup Terminal Settings for LM TerminalMenu Function Selection To access Local Management Accessing Local ManagementMicroMMAC-TLocal Management Screen Accessing Local Management via TelnetUsing Local Management Accessing Local Management from a ModemSetup Menu Screen Main Menu ScreenSetting or Modifying Local Management Screen Fields Working with Local Management ScreensSelecting a Menu Screen Option Exiting Your Local Management Session Exiting a Local Management ScreenSystem Level Screen Setting the System DateSetting the Host IP Address Setting the System TimeTo modify the Subnet Mask Modifying the Subnet MaskSetting the Default Gateway To set the Default GatewaySetting Automatic Beacon Recovery Process Abrp Fields To set the Beacon Recovery field Snmp Community Names Screen Setting COM 1 and COM 2 ApplicationsTo set the Number of Retries field To set the Retry Interval fieldSnmp Community Names Screen Snmp Traps Screen Access PolicyCommunity Name Editing the Community Name fieldSetting Snmp Traps Enable TrapsTrap Destination Trap Community NameRing Security Screen Ring Security Screen Security Mode Station AddressStn Edit Nextscreen SAVE/EXECUTEPreviousscreen ReturnViewing the Revised Allowed List Adding Stations to the Station Address Allowed ListDeleting Stations from the Station Address Allowed List Device Statistics Device Statistics ScreenSelecting the Device Statistics Counter Mode Using the Accumulative Counter ModeSetting the Refresh Field Isolating Errors Errors ReceivedRing Information AC ErrorsLost Frame Errors NON-ISOLATING ErrorsChassis Status View Screen Frame Copied ErrorsMode Next 10. Chassis Status View Operational Screen Using the Operational Mode ScreenTo display the status of ports To enable and disable select ports Using the Administrative Mode ScreenUsing the Ring OUT Enable Mode Screen To enable all ports for all modulesTo bypass all ports on a module To reconnect a module to the token ringComponent Status Screen To switch to and from STN and RO13. Component Status View Screen MIB Navigator ScreenTo access a list of MIB commands To get help on specific commandsTo escape from the MIB Navigator screen Navigational commands MIB CommandsNavigation Built-In Special Set Built-In commandsTo download a Flash image Flash Download ScreenTo chose the Runtime method Download Method fieldToggle from Runtime to Bootprom using the spacebar To choose the Bootprom methodLanview Leds Using Lanview LEDsLCD Display Using the LCD DisplayStatic System Messages Static System MessagesDisplayed Message Significance Alarm Messages Alarm MessagesDisplayed Significance Messages Unsaved Initialization Messages Unsaved Failure or Error MessagesNormal Unsaved Initialization Messages Saved System MessagesSaved System Messages Displayed MessageResponding to Error Messages Viewing Power UP Diagnostic TestsTo return to Local Management To execute a response optionPower Supply Cord