Cabletron Systems MICROMMAC-22T, 42T manual FCC Notice

Page 3

NOTICE

FCC NOTICE

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

DOC NOTICE

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

VCCI NOTICE

This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI) aimed at

preventing radio interference in commercial and/or industrial areas.

NEED JAP ANESE GRAPHIC TEXT HERE

BEFORE RELEASE

Consequently, when used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc.

Read the instructions for correct handling.

iv

Image 3
Contents Page Iii FCC Notice Cabletron SYSTEMS, INC. Program License Agreement United States Government Restricted Rights Contents Local Management TroubleshootingSaved System Messages Viewing Power UP Diagnostic Tests Chapter Introduction Contents OverviewMicroMMAC-T Overview Telnet MicroMMAC-T FeaturesLocal Management Cable Signal PolaritySpeed Fault Protection Active TCU PortsLanview LEDs Ring Speed SwitchCabletron’s Distributed LAN Monitor Mode Flash EepromMIB Support Reset ButtonCOM Port Applications LCD and LCD Display ButtonRmon MIB Support Rmon MIB RFC 1271/1513 SupportGroup Subgroup Section Stackable Capabilities Typical Stackable Configuration BRIDGING/ROUTING CapabilitiesBRIMs 1 SNA/WAN IntegrationRemote Management Capabilities Telnet CapabilitiesGetting Help Recommended ReadingMicroMMAC-T Ports/Cables Cable SpecificationsFrequency Impedance Attenuation UTP Cable SpecificationsAttenuation and Impedance UTP Voice Grade and Category 3 SpecificationsUTP Maximum Lobe Lengths Maximum Lobe LengthsType 3 Media Filters Maximum Number of StationsSTP Cable Specifications STP Cable SpecificationsTypes Frequency Impedance Attenuation STP Maximum Drive Distance Maximum Trunk LengthsSTP Maximum Lobe Lengths STP Cable Type Ring Speed MbpsCable Type Attenuation Maximum Drive Distance Mixed Cable TypesAttenuation Multimode Fiber Optic Cable SpecificationsSingle Mode Fiber Optic Cable Specifications Single Mode Fiber Optic Cable SpecificationsFiber Optic Budget Noise Cable RECOMMENDATIONS/TROUBLESHOOTINGTemperature CrosstalkCOM 1/COM 2 Ports COM Port SpecificationsTPIM-T1 Tpim SpecificationsUPS SlipTPIM-T1 Pinouts TPIM-T2TPIM-T4 Pinouts TPIM-F2Parameter Typical Minimum Maximum TPIM-F3TPIM-F2 Specifications Parameter Typical Worst Case Value BudgetREQUIREMENTS/SPECIFICATIONS Environmental Requirements General SpecificationsPower Supply Requirements Output Min. Load Max. Load Max PowerSafety ServicePhysical Attaching the Strain Relief Bracket Unpacking the MicroMMAC-TRack-Mounting the MicroMMAC-T Installing the MicroMMAC-TWall-Mounting the MicroMMAC-T Installing of Rack-Mount BracketsWall-Mounting the MicroMMAC-T Free-Standing Installation Connecting to a Power SourceResetting the MICROMMAC-T Setting the Ring Speed To reset the MicroMMAC-TTo change the ring speed To restore MicroMMAC-T parameters to the factory defaults Setting the Nvram SwitchRJ45 Plug MIC Connector Connecting Lobe Port CablingAt TCU At device port RJ45 Plug10. UTP Configuration Example 11. STP Configuration Example To attach a lobe segment to a MicroMMAC-T network portInstalling Tpim Modules Signal RJ45 DB9 Ring-In Ring-OutPinout Cross-Reference for TPIMs Setting Phantom and RI/RO Switches To install a TPIM, perform the following steps Tpim InstallationTo connect a TPIM-T1 to a Twisted Pair Segment Connecting STP SegmentsTo connect a segment to a TPIM-T2/-T4 Connecting Twisted Pair Segments16. The TPIM-T2/-T4 Connecting Fiber Optic Link Segments17. The TPIM-F2/-F3 To connect a fiber optic link segment to the TPIM-F2 /-F3To check MicroMMAC-T installation Checking the InstallationUse Local Management to Do the Following Management Terminal RequirementsManagement Terminal Setup Parameters Attaching the Management TerminalTo attach a management terminal to the MicroMMAC-T Modem Cable Configuration and Setup Terminal Settings for LM TerminalMenu Function Selection To access Local Management Accessing Local ManagementMicroMMAC-TLocal Management Screen Accessing Local Management via TelnetMain Menu Screen Accessing Local Management from a ModemUsing Local Management Setup Menu ScreenSetting or Modifying Local Management Screen Fields Working with Local Management ScreensSelecting a Menu Screen Option Exiting Your Local Management Session Exiting a Local Management ScreenSystem Level Screen Setting the System DateSetting the Host IP Address Setting the System TimeTo modify the Subnet Mask Modifying the Subnet MaskSetting the Default Gateway To set the Default GatewaySetting Automatic Beacon Recovery Process Abrp Fields To set the Beacon Recovery field To set the Retry Interval field Setting COM 1 and COM 2 ApplicationsSnmp Community Names Screen To set the Number of Retries fieldSnmp Community Names Screen Editing the Community Name field Access PolicySnmp Traps Screen Community NameTrap Community Name Enable TrapsSetting Snmp Traps Trap DestinationRing Security Screen Ring Security Screen Security Mode Station AddressStn Edit Return SAVE/EXECUTENextscreen PreviousscreenViewing the Revised Allowed List Adding Stations to the Station Address Allowed ListDeleting Stations from the Station Address Allowed List Device Statistics Device Statistics ScreenSelecting the Device Statistics Counter Mode Using the Accumulative Counter ModeSetting the Refresh Field Isolating Errors Errors ReceivedRing Information AC ErrorsLost Frame Errors NON-ISOLATING ErrorsChassis Status View Screen Frame Copied ErrorsMode Next 10. Chassis Status View Operational Screen Using the Operational Mode ScreenTo display the status of ports To enable and disable select ports Using the Administrative Mode ScreenTo reconnect a module to the token ring To enable all ports for all modulesUsing the Ring OUT Enable Mode Screen To bypass all ports on a moduleComponent Status Screen To switch to and from STN and RO13. Component Status View Screen MIB Navigator ScreenTo access a list of MIB commands To get help on specific commandsTo escape from the MIB Navigator screen Navigational commands MIB CommandsNavigation Built-In Special Set Built-In commandsTo download a Flash image Flash Download ScreenTo chose the Runtime method Download Method fieldToggle from Runtime to Bootprom using the spacebar To choose the Bootprom methodLanview Leds Using Lanview LEDsLCD Display Using the LCD DisplayStatic System Messages Static System MessagesDisplayed Message Significance Alarm Messages Alarm MessagesDisplayed Significance Messages Unsaved Initialization Messages Unsaved Failure or Error MessagesDisplayed Message Saved System MessagesNormal Unsaved Initialization Messages Saved System MessagesResponding to Error Messages Viewing Power UP Diagnostic TestsTo return to Local Management To execute a response optionPower Supply Cord