Extron electronic IPL T CR48 manual Front panel indicators, Resetting the unit

Page 20

Installation and Operation, cont’d

Front panel indicators

The front panel of the IPL T CR48 has several indicator LEDs which show the current status of communications to and from the unit. A reset button is also available from the front panel, in a small recess next to the Power LED (A).

IPL T CR48

 

INPUT

 

RELAY

 

100

5

 

1

3

1

3

5

7

 

 

 

 

 

 

R

 

 

 

 

 

LINK

6

 

 

 

 

 

 

 

ACT

7

 

2

4

2

4

6

8

 

 

 

 

1

2

3

 

 

4

 

 

 

Figure 2-8— IPL T CR48 front panel

A Power LED — A green LED lights to indicate that the interface is receiving power.

B Reset button (recessed) — See “Resetting the unit” later in this chapter for details on this multiple function reset button.

C D

Input LEDs — A green LED indicates that the port is active.

Relay LEDs — A green LED indicates that the relay is closed and activated.

E 100 LED — A green LED indicates that the connection speed is 100 Mbs. If the LED is not lit, the connection speed is 10 Mbs.

F Link LED — A green LED indicates that the unit is connected to an active network.

G Act (Activity) LED — A yellow LED lights to indicate that data is being sent/received.

Resetting the unit

There are five reset modes available by using the Reset button (B) on the front panel. The Reset button is recessed, so use of a pointed stylus, ballpoint pen, or Extron Tweeker is suggested.

CReview the reset modes carefully. Use of the wrong reset mode may result in unintended loss of flash memory programming, reassignment of ports, or a unit reboot.

2-8 IPL T CR48 • Installation and Operation

Image 20
Contents IPL T CR48 IP Link ToolsPrecautions Safety Instructions English安全须知 中文 FCC Class a NoticeThis page has been intentionally left blank Quick Start Guide IPL T CR48 IPL T CR48 Quick Start Guide QS-1Quick Start Guide -­ IPL T CR48, cont’d QS-2 IPL T CR48 Quick Start GuideTable of Contents Table of Contents, cont’d One Features IntroductionAbout this Manual About the IPL T CR48 InterfaceEasily configured and controlled Introduction, cont’d Two Installation and Operation Installation OverviewIPL T CR48 Installation and Operation Mounting the IPL T CR481U Rack Shelf Installation and Operation, cont’d Furniture or projector mountingRear Panel Features and Cabling IPL T CR48 interface back panel PowerIdentification Ethernet/LANConnections Example application using input and relay ports OperationFront panel indicators Resetting the unitIPL T CR48 Installation and Operation Installation and Operation, cont’d Three Connection and Configuration Connecting the HardwareIPL T CR48 Connection and Configuration Ethernet connectionIPL T CR48 Connection and Configuration Relay connectionsConnection and Configuration, cont’d Configuring the HardwarePC configuration IPL T CR48 interface configurationConfiguring the IPL T CR48 using the ARP command Executing the ARP command Configuring the IPL T CR48 using direct PC connection 255.255.0.0Firmware upgrades Four Communication and Control Ports OverviewContact closure input ports Relay portsAccessing and using the Web server Logon and system status Communication with the InterfaceWeb server IPL T CR48 Communication and ControlEstablishing or changing system or port settings Communication and Control, cont’dWeb server port settings screen Setting and changing your passwordsWeb server passwords screen Editing and adding e-mail alertsEmail alerts screen Sending an e-mail alert through TelnetUpgrading the firmware Managing filesWeb server File Management screen Using the command/response table 10- ASCII-to-HEX conversion table Symbol definitionsCommunication and Control = NvramCopyright information Copyright 2003, Extron Electronics IPL T CR48Password information Error responsesFirmware Version/Part Number/Information Relay functionsInput Contact Closure port IP Setup Commandsz IPL T CR48IPL T CR48 Communication Command Ascii Telnet URL Encoded Web ResponseControl EDH ECA File Commands Re-map port designationsWeb Browser Specific MailECM Event ControlReset ZAP/Erase Commands EAEAccessing and using Telnet Communication and Control, cont’d Device ControlCustom Web pages Telnet portTroubleshooting Power connectionsConfiguration Data connectionsAAppendix a Specifications, Part Numbers, Accessories SpecificationsIPL T CR48 Specifications, Part Numbers, and Accessories CE, CUL, ULAccessories Included parts Replacement Part numberAccessories Part number Included partsAppendixBB IPL T CR48 Glossary GlossaryGlossary IPL T CR48 Glossary Glossary, cont’d Extron’s Warranty USA, Canada, South America Japan Central AmericaExtron Electronics. All rights reserved
Related manuals
Manual 46 pages 9.65 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.