Extron electronic manual Quick Start Guide IPL T CR48, IPL T CR48 Quick Start Guide QS-1

Page 5

Quick Start Guide — IPL T CR48

To install and set up an IPL T CR48 interface, follow these steps:

Step 1

Turn all of the equipment off and disconnect it from the power source.

Projector

Lift

Control

Mounting Projector

Bolt Mounting

Bracket

Projector

IPLT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1INPUT3

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

3

5

 

 

 

 

 

 

 

 

 

 

 

 

4

2

4

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

100

IPLT

 

 

 

 

 

 

 

 

 

 

 

 

8

LINK

CR48

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

1U Rack Shelf

 

 

 

 

 

 

1INPUT3

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

LINK

 

 

 

 

 

 

 

 

2

 

3

6

8

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

4

2

4

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

 

 

1/4 Rack Width False Front

 

 

 

 

 

 

 

 

Face Plate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IPLT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

Use 2 mounting holes on

 

 

1INPUT3

 

RELAY

 

 

 

 

 

 

1

 

LINK

 

 

2

 

 

3

6

8

 

 

 

 

 

 

 

 

 

 

4

2

4

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

opposite corners.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IPLT

CR48

R

1INPUT

 

 

3

3RELAY

 

2

 

1

 

 

4

5

 

2

7

 

 

4

100

 

6

 

8

LINK

 

 

ACT

(2) 4-40 x 3/16" Screws

Step 2

Mount the IPL T CR48 interface near a screen, screen lift, lighting system, or projector lift, as illustrated below.

Step 3

Attach the network (LAN) cable to the IPL T CR48 unit and to a host PC, switch, hub, or router. See Ethernet connection in chapter 3 for more information on this connection.

00-05-A6-00-00-01

1

2

3

4

 

POWER

LAN

INPUT

 

 

 

 

 

 

 

 

RELAY

 

12V

 

 

 

 

 

 

1

2

3

4

5

6

7

8

0.5A

Extron IPL T CR48 Ethernet Control Interface

IPL T CR48 • Quick Start Guide

QS-1

Image 5
Contents IP Link Tools IPL T CR48Safety Instructions English PrecautionsFCC Class a Notice 安全须知 中文This page has been intentionally left blank IPL T CR48 Quick Start Guide QS-1 Quick Start Guide IPL T CR48QS-2 IPL T CR48 Quick Start Guide Quick Start Guide -­ IPL T CR48, cont’dTable of Contents Table of Contents, cont’d One Introduction FeaturesAbout this Manual About the IPL T CR48 InterfaceEasily configured and controlled Introduction, cont’d Two Installation Overview Installation and OperationIPL T CR48 Installation and Operation Mounting the IPL T CR481U Rack Shelf Furniture or projector mounting Installation and Operation, cont’dIPL T CR48 interface back panel Power Rear Panel Features and CablingIdentification Ethernet/LANConnections Operation Example application using input and relay portsResetting the unit Front panel indicatorsIPL T CR48 Installation and Operation Installation and Operation, cont’d Three Connecting the Hardware Connection and ConfigurationIPL T CR48 Connection and Configuration Ethernet connectionRelay connections IPL T CR48 Connection and ConfigurationConfiguring the Hardware Connection and Configuration, cont’dPC configuration IPL T CR48 interface configurationConfiguring the IPL T CR48 using the ARP command Executing the ARP command 255.255.0.0 Configuring the IPL T CR48 using direct PC connectionFirmware upgrades Four Ports Overview Communication and ControlContact closure input ports Relay portsCommunication with the Interface Accessing and using the Web server Logon and system statusWeb server IPL T CR48 Communication and ControlCommunication and Control, cont’d Establishing or changing system or port settingsSetting and changing your passwords Web server port settings screenEditing and adding e-mail alerts Web server passwords screenSending an e-mail alert through Telnet Email alerts screenManaging files Upgrading the firmwareWeb server File Management screen Using the command/response table Symbol definitions 10- ASCII-to-HEX conversion table= Nvram Communication and ControlCopyright 2003, Extron Electronics IPL T CR48 Copyright informationError responses Password informationFirmware Version/Part Number/Information Relay functionsInput Contact Closure port IPL T CR48 IP Setup CommandszIPL T CR48 Communication Command Ascii Telnet URL Encoded Web ResponseControl EDH ECA Re-map port designations File CommandsMail Web Browser SpecificEvent Control ECMEAE Reset ZAP/Erase CommandsCommunication and Control, cont’d Device Control Accessing and using TelnetCustom Web pages Telnet portPower connections TroubleshootingData connections ConfigurationAAppendix a Specifications Specifications, Part Numbers, AccessoriesCE, CUL, UL IPL T CR48 Specifications, Part Numbers, and AccessoriesIncluded parts Replacement Part number AccessoriesAccessories Part number Included partsAppendixBB IPL T CR48 Glossary GlossaryGlossary IPL T CR48 Glossary Glossary, cont’d USA, Canada, South America Japan Central America Extron’s WarrantyExtron Electronics. All rights reserved
Related manuals
Manual 46 pages 9.65 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.