Specifications

Ethernet control interface

Connectors

1 RJ-45 female connector

Data rate

10/100Base-T, half/full duplex with

 

autodetect

Protocols

ARP, DHCP, ICMP (ping), TCP/IP, UDP/

 

IP, Telnet, HTTP, SMTP

Default settings

Link speed and duplex level =

 

autodetected

 

IP address = 192.168.254.254

 

Subnet mask = 255.255.0.0

 

Gateway = 0.0.0.0

 

DHCP = off

Web server

Up to 200 simultaneous sessions

 

1.25 MB nonvolatile user memory

Program control

Extron’s Simple Instruction Set (SIS)

Global Viewer requirements

Microsoft® Internet Explorer ver. 6 or

 

higher

Relay control interface

Quantity/type

8 normally open relays

Relay control connectors

(2) 3.5 mm captive screw connectors, 8

 

pole

Relay control contact rating

24 V, 1 A

Contact closure control interface

Quantity/type

4 contact closure inputs

Contact input control connector..

(1) 3.5 mm captive screw connector, 5 pole

Contact closure (input only)

 

Input voltage range

0 to 5 VDC, clamped at +5.1 V

Input impedance

10k ohms

Threshold

1.6 VDC

Pin configurations

1, 2, 3, 4 = inputs 1, 2, 3, 4; 5 = GND

General

Power

Supplied by an included external power

 

supply

External power supply

100 VAC to 240 VAC, 50/60 Hz, external;

 

to 12 VDC, 1 A, regulated

Power input requirements

12 VDC, 0.5 A

A-2 IPL T CR48 • Specifications, Part Numbers, and Accessories

Image 58
Contents IPL T CR48 IP Link ToolsPrecautions Safety Instructions English安全须知 中文 FCC Class a NoticeThis page has been intentionally left blank Quick Start Guide IPL T CR48 IPL T CR48 Quick Start Guide QS-1Quick Start Guide -­ IPL T CR48, cont’d QS-2 IPL T CR48 Quick Start GuideTable of Contents Table of Contents, cont’d One About this Manual FeaturesIntroduction About the IPL T CR48 InterfaceEasily configured and controlled Introduction, cont’d Two IPL T CR48 Installation and Operation Installation and OperationInstallation Overview Mounting the IPL T CR481U Rack Shelf Installation and Operation, cont’d Furniture or projector mountingRear Panel Features and Cabling IPL T CR48 interface back panel PowerConnections Ethernet/LANIdentification Example application using input and relay ports OperationFront panel indicators Resetting the unitIPL T CR48 Installation and Operation Installation and Operation, cont’d Three IPL T CR48 Connection and Configuration Connection and ConfigurationConnecting the Hardware Ethernet connectionIPL T CR48 Connection and Configuration Relay connectionsPC configuration Connection and Configuration, cont’dConfiguring the Hardware IPL T CR48 interface configurationConfiguring the IPL T CR48 using the ARP command Executing the ARP command Configuring the IPL T CR48 using direct PC connection 255.255.0.0Firmware upgrades Four Contact closure input ports Communication and ControlPorts Overview Relay portsWeb server Accessing and using the Web server Logon and system statusCommunication with the Interface IPL T CR48 Communication and ControlEstablishing or changing system or port settings Communication and Control, cont’dWeb server port settings screen Setting and changing your passwordsWeb server passwords screen Editing and adding e-mail alertsEmail alerts screen Sending an e-mail alert through TelnetUpgrading the firmware Managing filesWeb server File Management screen Using the command/response table 10- ASCII-to-HEX conversion table Symbol definitionsCommunication and Control = NvramCopyright information Copyright 2003, Extron Electronics IPL T CR48Password information Error responsesInput Contact Closure port Relay functionsFirmware Version/Part Number/Information IP Setup Commandsz IPL T CR48Control Command Ascii Telnet URL Encoded Web ResponseIPL T CR48 Communication EDH ECA File Commands Re-map port designationsWeb Browser Specific MailECM Event ControlReset ZAP/Erase Commands EAECustom Web pages Accessing and using TelnetCommunication and Control, cont’d Device Control Telnet portTroubleshooting Power connectionsConfiguration Data connectionsAAppendix a Specifications, Part Numbers, Accessories SpecificationsIPL T CR48 Specifications, Part Numbers, and Accessories CE, CUL, ULAccessories Part number AccessoriesIncluded parts Replacement Part number Included partsAppendixBB Glossary GlossaryIPL T CR48 Glossary IPL T CR48 Glossary Glossary, cont’d Extron’s Warranty USA, Canada, South America Japan Central AmericaExtron Electronics. All rights reserved
Related manuals
Manual 46 pages 9.65 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.