Extron electronic IPL T CR48 manual Communication and Control, = Nvram

Page 42

Communication and Control

X1! = Unit version number

X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and/or a minus sign/hyphen (-). No blank or space characters are permitted as part of a name. No distinction is made between upper and lower case. The first character must be an alpha character. The last character can not be a minus sign/hyphen.

X1# = Set local date and time format (MM/DD/YY-HH:MM:SS, e.g., 06/21/02-10:54:00)

Read local date and time format (day of week, date month year HH:MM:SS, e.g., Thu, 20 Feb 2003 18:19:33)

X1$ = IP address (xxx.xxx.xxx.xxx); leading zeros in each of four fields are optional in setting values, and are suppressed in returned values.

X1% = Domain name (e.g., extron.com, icia.org)

X1* = Hardware (MAC) address (xx-xx-xx-xx-xx-xx)

X1( = Subnet mask (xxx.xxx.xxx.xxx); leading zeros in each of four fields are optional in setting values, and are suppressed in returned values.

X2@ = Status: 0 = working; 1 = fail

X2# = Priority status for receive timeout: 0 = priority set to Send Data String command parameters; 1 = priority set to Configure rcv timeout command parameters.

X3# = Password: maximum length of 12 characters and no special characters.

NUser password cannot be assigned if no administrator password exists and returns E14. If an admin password is cleared, then the user password is removed too.

X3$ = Daylight saving time: 0 = off/ignore; 1 = on (use in northern hemisphere)

X3% = Event number: range = 0 - 99 (Max.)

X3^ = Event buffer: 0 = receive; 1 = user (absolute); 2 = user (relative); 3

= NVRAM

X3& = Event buffer offset: range = 0 - MaxBufferSize

X3* = Event data size: b = bit; B = byte (8 bit); S = short (16 bit); L = long (32 bit)

NThis parameter is case sensitive.

4-12 IPL T CR48 • Communication and Control

Image 42
Contents IPL T CR48 IP Link ToolsPrecautions Safety Instructions English安全须知 中文 FCC Class a NoticeThis page has been intentionally left blank Quick Start Guide IPL T CR48 IPL T CR48 Quick Start Guide QS-1Quick Start Guide -­ IPL T CR48, cont’d QS-2 IPL T CR48 Quick Start GuideTable of Contents Table of Contents, cont’d One About this Manual FeaturesIntroduction About the IPL T CR48 InterfaceEasily configured and controlled Introduction, cont’d Two IPL T CR48 Installation and Operation Installation and OperationInstallation Overview Mounting the IPL T CR481U Rack Shelf Installation and Operation, cont’d Furniture or projector mountingRear Panel Features and Cabling IPL T CR48 interface back panel PowerEthernet/LAN ConnectionsIdentification Example application using input and relay ports OperationFront panel indicators Resetting the unitIPL T CR48 Installation and Operation Installation and Operation, cont’d Three IPL T CR48 Connection and Configuration Connection and ConfigurationConnecting the Hardware Ethernet connectionIPL T CR48 Connection and Configuration Relay connectionsPC configuration Connection and Configuration, cont’dConfiguring the Hardware IPL T CR48 interface configurationConfiguring the IPL T CR48 using the ARP command Executing the ARP command Configuring the IPL T CR48 using direct PC connection 255.255.0.0Firmware upgrades Four Contact closure input ports Communication and ControlPorts Overview Relay portsWeb server Accessing and using the Web server Logon and system statusCommunication with the Interface IPL T CR48 Communication and ControlEstablishing or changing system or port settings Communication and Control, cont’dWeb server port settings screen Setting and changing your passwordsWeb server passwords screen Editing and adding e-mail alertsEmail alerts screen Sending an e-mail alert through TelnetUpgrading the firmware Managing filesWeb server File Management screen Using the command/response table 10- ASCII-to-HEX conversion table Symbol definitionsCommunication and Control = NvramCopyright information Copyright 2003, Extron Electronics IPL T CR48Password information Error responsesRelay functions Input Contact Closure portFirmware Version/Part Number/Information IP Setup Commandsz IPL T CR48Command Ascii Telnet URL Encoded Web Response ControlIPL T CR48 Communication EDH ECA File Commands Re-map port designationsWeb Browser Specific MailECM Event ControlReset ZAP/Erase Commands EAECustom Web pages Accessing and using TelnetCommunication and Control, cont’d Device Control Telnet portTroubleshooting Power connectionsConfiguration Data connectionsAAppendix a Specifications, Part Numbers, Accessories SpecificationsIPL T CR48 Specifications, Part Numbers, and Accessories CE, CUL, ULAccessories Part number AccessoriesIncluded parts Replacement Part number Included partsAppendixBB Glossary GlossaryIPL T CR48 Glossary IPL T CR48 Glossary Glossary, cont’d Extron’s Warranty USA, Canada, South America Japan Central AmericaExtron Electronics. All rights reserved
Related manuals
Manual 46 pages 9.65 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.