Extron electronic manual IPL T CR48 Installation and Operation

Page 21

CThe listed reset modes (with the exception of Mode 2) will close all open IP and Telnet connections and close all sockets.

NIf the reset button is continuously held down, every 3 seconds the LED will pulse (blink) and put the unit in a different mode, corresponding to the underscored notes in Modes 3 through 5. The Mode 5 LED blinks three times, the third blink indicating that it’s the last mode. The following modes are listed as separate functions, not a continuation from Mode 1 to Mode 5.

Mode 1 — Holding the Reset button while applying power defaults the unit back to the base firmware that shipped with the unit from the factory. Event scripting does not start when the unit is powered on in this mode. This allows you to recover a unit that has incorrect code or updated firmware running. All user files and settings are maintained. User Web pages may not work correctly if using an earlier firmware version.

Mode 2 — Not applicable.

Mode 3 — Holding the Reset button until the Power LED blinks once (3 seconds) followed by a momentary

(<1 second) press will turn events either on or off, depending on the current state of the events:

If the events are currently stopped following the momentary (<1 second) press, the Power LED will flash twice indicating the starting of events.

or

If events are currently running following the momentary (<1 second) press, the Power LED will flash three times indicating the stopping of events.

Each flash will last for .25 seconds. Nothing happens if the momentary press does not occur within 1 second.

Mode 4 — Holding the Reset button until the Power LED blinks twice (6 seconds) followed by a momentary (<1 second) press resets IP settings. The Power LED will blink four times in quick succession, confirming a Mode 4 reset. This mode

1.Enables ARP program capability

2.Sets IP back to factory IP

3.Sets Subnet back to factory default

4.Sets Gateway back to factory default

5.Sets port mapping back to factory default

6.Turns DHCP off

7.Turns events off

IPL T CR48 • Installation and Operation

2-9

Image 21
Contents IP Link Tools IPL T CR48Safety Instructions English PrecautionsFCC Class a Notice 安全须知 中文This page has been intentionally left blank IPL T CR48 Quick Start Guide QS-1 Quick Start Guide IPL T CR48QS-2 IPL T CR48 Quick Start Guide Quick Start Guide -­ IPL T CR48, cont’dTable of Contents Table of Contents, cont’d One Introduction FeaturesAbout this Manual About the IPL T CR48 InterfaceEasily configured and controlled Introduction, cont’d Two Installation Overview Installation and OperationIPL T CR48 Installation and Operation Mounting the IPL T CR481U Rack Shelf Furniture or projector mounting Installation and Operation, cont’dIPL T CR48 interface back panel Power Rear Panel Features and CablingEthernet/LAN ConnectionsIdentification Operation Example application using input and relay portsResetting the unit Front panel indicatorsIPL T CR48 Installation and Operation Installation and Operation, cont’d Three Connecting the Hardware Connection and ConfigurationIPL T CR48 Connection and Configuration Ethernet connectionRelay connections IPL T CR48 Connection and ConfigurationConfiguring the Hardware Connection and Configuration, cont’dPC configuration IPL T CR48 interface configurationConfiguring the IPL T CR48 using the ARP command Executing the ARP command 255.255.0.0 Configuring the IPL T CR48 using direct PC connectionFirmware upgrades Four Ports Overview Communication and ControlContact closure input ports Relay portsCommunication with the Interface Accessing and using the Web server Logon and system statusWeb server IPL T CR48 Communication and ControlCommunication and Control, cont’d Establishing or changing system or port settingsSetting and changing your passwords Web server port settings screenEditing and adding e-mail alerts Web server passwords screenSending an e-mail alert through Telnet Email alerts screenManaging files Upgrading the firmwareWeb server File Management screen Using the command/response table Symbol definitions 10- ASCII-to-HEX conversion table= Nvram Communication and ControlCopyright 2003, Extron Electronics IPL T CR48 Copyright informationError responses Password informationRelay functions Input Contact Closure portFirmware Version/Part Number/Information IPL T CR48 IP Setup CommandszCommand Ascii Telnet URL Encoded Web Response ControlIPL T CR48 Communication EDH ECA Re-map port designations File CommandsMail Web Browser SpecificEvent Control ECMEAE Reset ZAP/Erase CommandsCommunication and Control, cont’d Device Control Accessing and using TelnetCustom Web pages Telnet portPower connections TroubleshootingData connections ConfigurationAAppendix a Specifications Specifications, Part Numbers, AccessoriesCE, CUL, UL IPL T CR48 Specifications, Part Numbers, and AccessoriesIncluded parts Replacement Part number AccessoriesAccessories Part number Included partsAppendixBB Glossary GlossaryIPL T CR48 Glossary IPL T CR48 Glossary Glossary, cont’d USA, Canada, South America Japan Central America Extron’s WarrantyExtron Electronics. All rights reserved
Related manuals
Manual 46 pages 9.65 Kb

IPL T CR48 specifications

The Extron IPL T CR48 is a cutting-edge technology solution designed for modern audiovisual environments. As a compact, high-performance control processor, it is specifically tailored for managing and automating AV systems in various settings, including classrooms, conference rooms, and other collaborative spaces. The IPL T CR48 seamlessly integrates with a wide range of Extron products and third-party devices, making it a versatile choice for any AV installation.

One of the main features of the IPL T CR48 is its powerful control capabilities. It supports up to 48 programmable control ports, which allow users to manage multiple displays, projectors, and other audiovisual equipment effortlessly. This extensive control range ensures that every device in the AV system is easily operable from a single interface, streamlining the user experience.

In addition to its impressive control capabilities, the IPL T CR48 integrates advanced IPLink technology. This unique feature allows for remote control and monitoring of AV systems over an IP network, offering system administrators the flexibility to manage equipment from virtually anywhere. This capability is particularly valuable in large installations, where managing multiple systems simultaneously can be complex and time-consuming.

The IPL T CR48 also boasts a user-friendly interface, thanks to its compatibility with Extron's GlobalViewer Enterprise software. This robust software provides users with a web-based platform for real-time monitoring and management of their AV systems. It enables users to configure, schedule, and control their AV devices, ensuring a smooth operation throughout all events and presentations.

Moreover, the IPL T CR48 is engineered with enhanced security features, including customizable user access levels, ensuring that only authorized personnel can control sensitive equipment. This aspect is crucial for educational and corporate environments, where security and privacy are paramount.

Compact and reliable, the IPL T CR48 excels in both functionality and performance. Its durable design and advanced technologies make it a preferred choice among AV professionals looking to improve the efficiency of their installations. Overall, the Extron IPL T CR48 represents a significant advancement in control processing technology, providing a comprehensive solution for diverse audiovisual applications today.