Extron electronic MTPX PLUS 1632 Accessing the Html Pages, Selecting Mtpx Plus Pre-Peak

Page 27

Remote Control and Optimizing the Video, cont’d

NA 2-nanosecond adjustment is very fine. Up to 10 nanoseconds of delay may be necessary before you detect a change in the display.

14. Adjust the leftmost video signal to the right until all three colors are converged.

15. If either of the two the remaining colors is left shifted, repeat steps 12 and 14.

16. Repeat steps 10 through 15 for all other outputs.

Selecting MTPX Plus Pre-Peak

NMTPX Pre-Peak is available on all outputs of an MTPX Plus 128 and the first half of MTPX Plus outputs of the remaining MTPX Plus models (for example, outputs 1 through 4 for an MTPX Plus 168).

NIf the cable between the MTPX Plus and the receiver is 300 feet (91 m) or longer, turn the Pre-Peak feature on the MTPX Plus on. For shorter cables, turn the feature off.

If necessary, click Tools > MTPX Picture settings and then click in the output Pre-Peaking box to toggle Pre-Peaking on and off.

Setting MTP Receiver level/peaking

If level/peaking is available on the connected receiver, adjust it as follows:

1.

Connect an oscilloscope or monitor to the output of the

 

MTP receiver.

2.

If using an oscilloscope, apply a white field test pattern to

 

one of the local (VGA) inputs on the MTPX Plus.

If using a monitor, apply a grayscale test pattern to one of the local (VGA) inputs on the MTPX Plus.

HThe Extron VTG 300 or VTG 400 are recommended to provide the test pattern.

3.

Tie the local input receiving the test pattern signal to the

 

output connected to the MTP receiver to be optimized.

 

VTG 300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Local (VGA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

MTPX Plus

 

 

 

LOCAL INPUTS

 

LOCAL OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RGB

 

RGB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

2

 

 

31

2

3

4INPUTS5

6

7

8

1

2

3

OUTPUTS4 5

6

7

8

Receiver

Oscilloscope

 

1

 

 

 

 

 

 

 

 

 

 

 

 

RS - 232 OUTPUT INSERT

 

 

MTP

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

RGB

 

RGB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or display

 

MONO AUDIO OUTPUTS

9

10

11

12

13

14

15

16

9

10

11

12

13

14

15

16

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Adjust the level and peaking on the receiver in accordance

 

with the applicable MTP product manual.

 

5.

Repeat steps 1 through 4 for each receiver to be optimized.

Accessing the HTML Pages

Another way to operate the switcher is via its factory-installed HTML pages, which are always available and cannot be erased or overwritten. The HTML pages are accessible through the LAN port of the switcher when it is connected via a LAN or WAN, using a web browser such as Microsoft Internet Explorer. See k on page 2-6 for connection information.

4-22 MTPX Plus Series • Remote Control and Optimizing the Video

MTPX Plus Series • Remote Control and Optimizing the Video 4-23

Refer also to the MTPX Plus User’s Manual at www.extron.com.

Refer also to the MTPX Plus User’s Manual at www.extron.com.

Image 27
Contents Mini Twisted Pair Matrix Switchers Setup GuideExtron Warranty PrecautionsFCC Class a Notice 安全须知 中文Table of Contents Table of Contents, cont’d Mtpx Plus Series Matrix SwitcherExtron Mtpx Plus About the Mtpx Plus SwitchersIntroduction About this ManualTP Skew Equalization VideoFormat Introduction, cont’d TwoInputs InstallationMtpx Plus Series Installlation Rear PanelOutputs Installation, cont’dRemote control RS-232 output insertsPower Configuration port switchers other than the Mtpx PlusFront Panel Mtpx Plus Series Front Panel Operation Saving or Recalling a PresetFront Panel Operation Creating a TieMtpx Plus Series Front Panel Operation Selecting Lock mode 2 or toggling between mode 2 and modeConfiguration for that input Viewing and Adjusting the Audio LevelVideo Adjustments Front Panel Operation, cont’dViewing Ties and Muting Outputs Establishing a network Ethernet connection Remote Control and Optimizing the VideoSelected SIS Commands Host-to-switcher instructionsCommand Ascii command Response Additional description Remote Control and Optimizing the Video, cont’dCommand/response table for selected SIS commands Mtpx Plus Series Remote Control and Optimizing the VideoEX!*X+Iseq IseqX!*X**X**X EX! *X IpekEX! Ipek EX!*X**X**X*Iseq IseqX!*X**X**XEX1Opek EX@ *X +OseqEX@ *X -Oseq EX@ OseqRemote Control and Optimizing the Video, cont’d SprX2 @*X1V@+V @-VWww IP setupInstalling the program Installing and Starting the Control ProgramUSB port connection First-time connection considerationsStarting the program LAN port connectionOptimizing the video Is the factory-specified default value for this fieldSetting Mtpx skew Manually setting the Mtpx level and peakingSelecting Mtpx Plus Pre-Peak Accessing the Html PagesSetting MTP Receiver level/peaking Mtpx Plus Series Remote Control and Optimizing the VideoLoading the start-up Configuring for Network CommunicationStart the Web browser program Remote Control and Optimizing the Video, cont’d