Extron electronic MTPX PLUS 168, MTPX PLUS 816, MTPX PLUS 1616 Start the Web browser program

Page 29

Remote Control and Optimizing the Video, cont’d

1.

Start the Web browser program.

2.

Click in the browser’s Address field.

3.

Enter the Matrix IP address in the browser’s Address field.

N192.168.254.254 is the factory-specified default value for this field.

4.

Press the keyboard Enter key. The switcher checks to see if

 

it is password protected.

If the switcher is not password protected, it checks and downloads the HTML start-up page. The switcher is ready for operation via HTML remote control.

If the switcher is password protected, it downloads the Enter Network Password page.

NA User name entry is not required.

5.

Enter the appropriate administrator or user password in

 

the Password field and click OK.

6.

The switcher downloads the HTML start-up page. The

 

switcher is ready for operation via HTML remote control.

4-26 MTPX Plus Series • Remote Control and Optimizing the Video

MTPX Plus Series • Remote Control and Optimizing the Video 4-27

Refer also to the MTPX Plus User’s Manual at www.extron.com.

Refer also to the MTPX Plus User’s Manual at www.extron.com.

Image 29
Contents Mini Twisted Pair Matrix Switchers Setup GuideExtron Warranty PrecautionsFCC Class a Notice 安全须知 中文Table of Contents Table of Contents, cont’d Mtpx Plus Series Matrix SwitcherIntroduction About the Mtpx Plus SwitchersAbout this Manual Extron Mtpx PlusFormat TP Skew EqualizationVideo Introduction, cont’d TwoMtpx Plus Series Installlation InstallationRear Panel InputsRemote control Installation, cont’dRS-232 output inserts OutputsFront Panel PowerConfiguration port switchers other than the Mtpx Plus Front Panel Operation Saving or Recalling a PresetCreating a Tie Mtpx Plus Series Front Panel OperationMtpx Plus Series Front Panel Operation Selecting Lock mode 2 or toggling between mode 2 and modeConfiguration for that input Viewing and Adjusting the Audio LevelViewing Ties and Muting Outputs Video AdjustmentsFront Panel Operation, cont’d Selected SIS Commands Remote Control and Optimizing the VideoHost-to-switcher instructions Establishing a network Ethernet connectionCommand/response table for selected SIS commands Remote Control and Optimizing the Video, cont’dMtpx Plus Series Remote Control and Optimizing the Video Command Ascii command Response Additional descriptionEX! Ipek EX! *X IpekEX!*X**X**X*Iseq IseqX!*X**X**X EX!*X+Iseq IseqX!*X**X**XEX@ *X -Oseq EX@ *X +OseqEX@ Oseq EX1OpekRemote Control and Optimizing the Video, cont’d @+V @*X1V@-V SprX2Www IP setupInstalling the program Installing and Starting the Control ProgramStarting the program First-time connection considerationsLAN port connection USB port connectionOptimizing the video Is the factory-specified default value for this field Setting Mtpx skew Manually setting the Mtpx level and peakingSetting MTP Receiver level/peaking Accessing the Html PagesMtpx Plus Series Remote Control and Optimizing the Video Selecting Mtpx Plus Pre-PeakLoading the start-up Configuring for Network CommunicationStart the Web browser program Remote Control and Optimizing the Video, cont’d