into the
AC POWER INPUT
FUSE: 250V 0.8A TT
Checking/Replacing the BME Internal Power Supply AC Input Fuses
Each internal power supply has an AC input fuse. If a power supply fuse blows, the Front Panel LED for that power supply will go OFF (it is normally solid ON). If the BME has redundant power supplies, the redundant supply for the failed power supply will assume the full load and its front panel diagnostic LED will blink indicating that the Main (Primary) power supply is inoperative. To check/replace a power supply fuse, unplug the AC power cord from the BME rear panel, remove the Access Panel (see Page
Primary V+
Power Supply
Fuse | 19 |
| J1 |
20 | 1 |
| 2 |
Redundant V+ Power Supply would be located here
POWER+V |
|
|
|
| |
PRIMARY |
|
|
REDUNDANT TX RS232 |
|
|
RX COMMUNICATIONSBME |
| |
DIAGNOSTICS | REMOTE | SYSTEM |
| ||
|
| STATUS |
|
| Primary V- |
|
| Power Supply |
|
| (Redundant V- |
|
| would be |
|
| located beside |
|
| Primary |
Figure 5-6.A BME exploded view
POWER SUPPLIES | COMMUNICATIONS | SYSTEM | ||
+V |
|
|
| |
RS232 | BME | REMOTE | STATUS | |
PRIMARY | TX |
|
|
|
REDUNDANTRX
DIAGNOSTICS
Matrix 3200/6400 Series • Upgrades and Troubleshooting |