Extron electronic PS 124 installation manual Output power wiring the DC output connectors

Page 14

PS 124, cont’d

Output power — wiring the DC output connectors

The PS 124 can supply 12 VDC to multiple devices using

3.5mm, 2-pole captive screw connectors. The combined current draw of the connected devices must not exceed 4 amps.

NTo verify proper polarity before connection to a device, plug in the power supply with no load and check the output polarity with a voltmeter. Remove power before continuing.

WWhen verifying power supply polarity, the two power cord wires must be kept separate while the power supply is plugged in.

To connect products to the outputs of the PS 124:

1. Cut the DC output cord to the length required.

2. Strip the jacket of the conductor wire (figure 8).

Smooth

Ridges

A

A

Power Supply

Output Cord

+

SECTION A–A

Tie Wrap

2-Pole Orange

Captive Screw

Connector

(12V)

3/16”

(5 mm) Max.

Smooth

Ridges

Figure 8 — Power connector wiring

NThe length of the exposed (stripped) copper wires is important. The ideal length is 3/16" (5 mm). Longer bare wires can short together. Shorter wires are not as secure in the captive screw connectors and could be pulled out.

Do not tin the stripped power supply leads. Tinned wires are not as secure in the captive screw connectors and could be pulled out.

3. Slide the leads into the supplied 2-pole captive screw plug and secure using an Extron Tweeker or small screwdriver.

4. Use the supplied tie wrap to strap the power cord to the extended tail of the connector.

8 PS 124 12 VDC, 4 Amp Power Supply • Installation Manual

Image 14
Contents Installation Manual 12 VDC, 4 Amp Power SupplyPrecautions FCC Class B Notice Vcci Class B notice for ITE productsPage Table of Contents Table of Contents, cont’d Power status LEDs These front and rear panel LEDs indicate Front and Rear Panel FeaturesLED indicators IntroductionInput Power PS 124, cont’d12VDC 4A Power Supply PS 124 supports up to eight power supply outputs. ForConnectors, see Output power wiring the DC output DC OutputsPS 124, cont’d Connections Input power using the IEC power cordInput power using the Flexible Conduit Adapter Kit UL guidelines This unit must be installed in accordance with the NationalInstalling the flexible conduit cable Unscrew the ground wire nut on the bottom of the PS Removing the top coverSee out of the enclosure From the conduit kit, thread the 18-gauge power wiresInstall the EMT adapter plate into the opening Output power wiring the DC output connectors PS 124 can supply 12 VDC to multiple devices usingInstalling the PS UL rack mounting guidelinesRack mounting Rack mounting the PSPS 124 12 VDC, 4 Amp Power Supply Installation Manual Under-desk mountingTo mount the PS 124 onto the PMK 350 bracket Above-projector mountingPMK Pass the legs through the holes in the L-shaped bracket 14 PS 124 12 VDC, 4 Amp Power Supply Installation Manual Specifications GeneralIncluded Parts AccessoriesAccessories Part number Included parts Part numberExtron’s Warranty USA, Canada, South America Central AmericaExtron Electronics. All rights reserved