Extron electronic PS 124 Introduction, Front and Rear Panel Features, LED indicators

Page 7

Introduction

The Extron PS 124 is a high performance, plenum rated (with optional Flexible Conduit kit), 12 VDC power supply. The autoswitchable 100 VAC to 240 VAC input can supply a maximum current of 4 amps for up to eight outputs. Each DC output is on a two-pole captive screw connector, with no per-output current limitation. Two-tone LEDs on the front and rear panels indicate normal operation (green) and overload condition (red).

The rack mountable PS 124 has a 1U high, quarter rack wide, 9" deep metal enclosure, allowing the PS 124 to take advantage of a variety of mounting options.

Front and Rear Panel Features

All power and output connections are on the rear panel.

100-240

50-60Hz 1.2A MAX.

 

 

OUTPUTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED-OVERLOAD

P/S 124

12 VDC 4A POWER SUPPLY

C

RED-

OVERLOAD

12 V TOTAL OUTPUT 4A

D E C F

100-240

50-60Hz 1.2A MAX.

 

 

OUTPUTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED-

OVERLOAD

12 V TOTAL OUTPUT 4A

Figure 1 — PS 124 front and rear panels

LED indicators

A

Power status LEDs — These front and rear panel LEDs indicate

 

the PS 124 status by lighting as follows:

 

Green when power is applied and current draw is normal

 

Red indicates a current overload condition

 

C Continued operation in an overload condition may

 

cause premature power supply failure.

 

Unlit when an output is shorted

 

N To identify the shorted output, unplug the outputs one at

 

a time until the LEDs light green.

PS 124 12 VDC, 4 Amp Power Supply • Installation Manual

1

Image 7
Contents 12 VDC, 4 Amp Power Supply Installation ManualPrecautions Vcci Class B notice for ITE products FCC Class B NoticePage Table of Contents Table of Contents, cont’d Introduction Front and Rear Panel FeaturesLED indicators Power status LEDs These front and rear panel LEDs indicatePS 124, cont’d Input PowerDC Outputs PS 124 supports up to eight power supply outputs. ForConnectors, see Output power wiring the DC output 12VDC 4A Power SupplyInput power using the Flexible Conduit Adapter Kit Input power using the IEC power cordPS 124, cont’d Connections Installing the flexible conduit cable This unit must be installed in accordance with the NationalUL guidelines Removing the top cover Unscrew the ground wire nut on the bottom of the PSInstall the EMT adapter plate into the opening From the conduit kit, thread the 18-gauge power wiresSee out of the enclosure PS 124 can supply 12 VDC to multiple devices using Output power wiring the DC output connectorsUL rack mounting guidelines Installing the PSRack mounting the PS Rack mountingUnder-desk mounting PS 124 12 VDC, 4 Amp Power Supply Installation ManualPMK Above-projector mountingTo mount the PS 124 onto the PMK 350 bracket Pass the legs through the holes in the L-shaped bracket 14 PS 124 12 VDC, 4 Amp Power Supply Installation Manual General SpecificationsIncluded parts Part number AccessoriesAccessories Part number Included PartsUSA, Canada, South America Central America Extron’s WarrantyExtron Electronics. All rights reserved