Extron electronic installation manual PS 124, cont’d, Input Power

Page 8

PS 124, cont’d

Input Power

 

Apply power to the PS 124 using the supplied IEC power cord

 

(B) or by installing the optional Flexible Conduit Adapter Kit

 

(Extron part #70-228-02) (C).

B

IEC connector/power supply — Plug the IEC cord into this

 

connector and a 100–240 VAC source.

-OR- C

Optional conduit adapter plate — The IEC connector and

 

adapter plate can be replaced by this half-inch conduit EMT

 

(Electrical Metallic Tubing) adapter plate, as shown in figure 2.

 

See “Input power — using the Flexible Conduit Adapter Kit,”

 

on page 4.

 

N With the installation of the Flexible Conduit Adapter kit,

 

the PS 124 is suitable for use in air handling spaces and

 

meets all applicable requirements of UL 2043.

For plenum applications replace this plate with optional flex conduit kit, part #70-228-02.

Extron

PS 124

12 VDC 4 A Power Supply

100-240 50-60Hz 1.2A MAX.OUTPUTS

12 VDC TOTAL OUTPUT 4A

1

2

3

4

5

6

7

8

 

 

100-240

50-60Hz 1.2A MAX.

OUTPUTS

 

 

 

 

 

 

 

12 VDC TOTAL OUTPUT 4A

 

 

 

Figure 2 — Using the conduit option

2 PS 124 12 VDC, 4 Amp Power Supply • Installation Manual

Image 8
Contents Installation Manual 12 VDC, 4 Amp Power SupplyPrecautions FCC Class B Notice Vcci Class B notice for ITE productsPage Table of Contents Table of Contents, cont’d Front and Rear Panel Features LED indicatorsPower status LEDs These front and rear panel LEDs indicate IntroductionInput Power PS 124, cont’dPS 124 supports up to eight power supply outputs. For Connectors, see Output power wiring the DC output12VDC 4A Power Supply DC OutputsPS 124, cont’d Connections Input power using the IEC power cordInput power using the Flexible Conduit Adapter Kit UL guidelines This unit must be installed in accordance with the NationalInstalling the flexible conduit cable Unscrew the ground wire nut on the bottom of the PS Removing the top coverSee out of the enclosure From the conduit kit, thread the 18-gauge power wiresInstall the EMT adapter plate into the opening Output power wiring the DC output connectors PS 124 can supply 12 VDC to multiple devices usingInstalling the PS UL rack mounting guidelinesRack mounting Rack mounting the PSPS 124 12 VDC, 4 Amp Power Supply Installation Manual Under-desk mountingTo mount the PS 124 onto the PMK 350 bracket Above-projector mountingPMK Pass the legs through the holes in the L-shaped bracket 14 PS 124 12 VDC, 4 Amp Power Supply Installation Manual Specifications GeneralAccessories Accessories Part numberIncluded Parts Included parts Part numberExtron’s Warranty USA, Canada, South America Central AmericaExtron Electronics. All rights reserved