Extron electronic PS 124 Pass the legs through the holes in the L-shaped bracket

Page 19

5. Assemble the U-bolt and the following parts in order:

a. Pass the legs of the U-bolt through the slotted holes on the mount plate flange.

b. Place the legs around the ceiling pole.

c. Pass the legs through the holes in the contoured base.

NThe pole fits snugly into the depression in the center of the contoured base.

d. Pass the legs through the holes in the L-shaped bracket.

NThe bracket slots can accommodate 1.0" to 2.0" diameter poles. The supplied square U-bolt fits 1.5" to 2.0" diameter poles. If a smaller diameter pole is used, obtain the proper size square U-bolt locally.

Mount Plate

Flange

Contoured

Base

U-bolt

L-shaped Bracket

Slotted Hole

L-shaped

in PMK Tray

Bracket Screws

 

Ceiling

Pole

Figure 12 — Projector mounting the PS 124

6. Align the two slotted holes in the bottom of the L-shaped bracket with the two slotted holes in the base of the tray. Secure the L-bracket to the base by inserting two

6-32 x 5/16" screws (provided) through the aligned slots.

7. Move the PMK 350 to the desired location on the ceiling pole, as close to the ceiling as desired.

8. Secure the L-shaped bracket to the U-bolt using the included hex nuts, washers, and lock washers. Tighten the hex nuts securely.

CA socket wrench is recommended to tighten the hex nuts so the PMK 350 does not slide down the ceiling pole.

9. Secure the front panel to the mounting tray with four of the included #6 screws.

10.If desired, apply one of the cover sheets to the underside of the mounting tray (figure 11).

PS 124 12 VDC, 4 Amp Power Supply • Installation Manual

13

Image 19
Contents 12 VDC, 4 Amp Power Supply Installation ManualPrecautions Vcci Class B notice for ITE products FCC Class B NoticePage Table of Contents Table of Contents, cont’d Introduction Front and Rear Panel FeaturesLED indicators Power status LEDs These front and rear panel LEDs indicatePS 124, cont’d Input PowerDC Outputs PS 124 supports up to eight power supply outputs. ForConnectors, see Output power wiring the DC output 12VDC 4A Power SupplyInput power using the Flexible Conduit Adapter Kit Input power using the IEC power cordPS 124, cont’d Connections Installing the flexible conduit cable This unit must be installed in accordance with the NationalUL guidelines Removing the top cover Unscrew the ground wire nut on the bottom of the PSInstall the EMT adapter plate into the opening From the conduit kit, thread the 18-gauge power wiresSee out of the enclosure PS 124 can supply 12 VDC to multiple devices using Output power wiring the DC output connectorsUL rack mounting guidelines Installing the PSRack mounting the PS Rack mountingUnder-desk mounting PS 124 12 VDC, 4 Amp Power Supply Installation ManualPMK Above-projector mountingTo mount the PS 124 onto the PMK 350 bracket Pass the legs through the holes in the L-shaped bracket 14 PS 124 12 VDC, 4 Amp Power Supply Installation Manual General SpecificationsIncluded parts Part number AccessoriesAccessories Part number Included PartsUSA, Canada, South America Central America Extron’s WarrantyExtron Electronics. All rights reserved