Extron electronic PS 124 See out of the enclosure, Install the EMT adapter plate into the opening

Page 13

7.

From the rear panel end, pull the IEC connector

 

(see figure 4) out of the enclosure.

8.

From the conduit kit, thread the 18-gauge power wires

 

through the length of the electrical conduit tube.

9.

Install the EMT adapter plate (figure 2) into the opening.

 

Use the Phillips head screws removed in step 2 (figure 4) to

 

attach the adapter plate.

NIf the conduit is attached to the EMT plate, skip step 10.

10. Slide the conduit nut (figure 7, below) over the bundle of wires exiting the conduit and onto the conduit itself inside the PS 124. Hand-tighten the nut.

Terminal Block

Hot Terminal

Metal Tab

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tie Wrap

Neutral Terminal

Ground Wire Nut

Conduit Nut

Figure 7 — Terminal block and conduit wiring

11.Attach and fasten the hot and neutral wires from the conduit to their corresponding screws on the terminal block.

WEnsure wire polarity is observed. Figure 7 shows the location of the neutral and hot terminals on the terminal block. The conduit wiring harness neutral wire is identified with a tag marked "N" (neutral).

12.Attach the ground wire from the conduit to the chassis ground, securing it by reattaching the ground wire nut.

13.Thread a tie wrap through the metal tab on the bottom of the PS 124, place all the wires within its cradle, and zip the tie wrap over the bundle of wires.

14.Tighten the conduit nut (figure 7 above) to ensure it firmly secures the conduit to the EMT adapter plate.

15.Use the screws removed in step 3 to fasten the top cover of the PS 124 back onto the chassis (figure 5).

PS 124 12 VDC, 4 Amp Power Supply • Installation Manual

7

Image 13
Contents 12 VDC, 4 Amp Power Supply Installation ManualPrecautions Vcci Class B notice for ITE products FCC Class B NoticePage Table of Contents Table of Contents, cont’d LED indicators Front and Rear Panel FeaturesPower status LEDs These front and rear panel LEDs indicate IntroductionPS 124, cont’d Input PowerConnectors, see Output power wiring the DC output PS 124 supports up to eight power supply outputs. For12VDC 4A Power Supply DC OutputsInput power using the Flexible Conduit Adapter Kit Input power using the IEC power cordPS 124, cont’d Connections Installing the flexible conduit cable This unit must be installed in accordance with the NationalUL guidelines Removing the top cover Unscrew the ground wire nut on the bottom of the PSInstall the EMT adapter plate into the opening From the conduit kit, thread the 18-gauge power wiresSee out of the enclosure PS 124 can supply 12 VDC to multiple devices using Output power wiring the DC output connectorsUL rack mounting guidelines Installing the PSRack mounting the PS Rack mountingUnder-desk mounting PS 124 12 VDC, 4 Amp Power Supply Installation ManualPMK Above-projector mountingTo mount the PS 124 onto the PMK 350 bracket Pass the legs through the holes in the L-shaped bracket 14 PS 124 12 VDC, 4 Amp Power Supply Installation Manual General SpecificationsAccessories Part number AccessoriesIncluded Parts Included parts Part numberUSA, Canada, South America Central America Extron’s WarrantyExtron Electronics. All rights reserved