Gigabyte GA-K8NMF-9 user manual Serial ATA Bios Setting Utility Introduction, RAID Levels

Page 64

English

4-1-4 Serial ATA BIOS Setting Utility Introduction

RAID Levels

RAID (Redundant Array of Independent Disks) is a method of combining two hard disk drives into one logical unit. The advantage of an Array is to provide better performance or data fault tolerance. Fault tolerance is achieved through data redundant operation, where if one drives fails, a mirrored copy of the data can be found on another drive. This can prevent data loss if the operating system fails or hangs. The individual disk drives in an array are called members. The configuration information of each member is recorded in the reserved sector that identifies the drive as a member. All disk members in a formed disk array are recognized as a single physical drive to the operating system.

Hard disk drives can be combined together through a few different methods. The different methods are referred to as different RAID levels. Different RAID levels represent different performance levels, security levels and implementation costs. The RAID levels which the nVIDIA® nForce4(-4X) chipset supports are RAID 0, RAID 1, RAID 0+RAID 1 and JBOD.

RAID 0 (Striping)

RAID 0 reads and writes sectors of data interleaved between multiple drives. If any disk member fails, it affects the entire array. The disk array data capacity is equal to the number of drive members times the capacity of the smallest member. The striping block size can be set from 4KB to 128KB. RAID 0 does not support fault tolerance.

RAID 1 (Mirroring)

RAID 1 writes duplicate data onto a pair of drives and reads both sets of data in parallel. If one of the mirrored drives suffers a mechanical failure or does not respond, the remaining drive will continue to function. Due to redundancy, the drive capacity of the array is the capacity of the smallest drive. Under a RAID 1 setup, an extra drive called the spare drive can be attached. Such a drive will be activated to replace a failed drive that is part of a mirrored array. Due to the fault tolerance, if any RAID 1 drive fails, data access will not be affected as long as there are other working drives in the array.

RAID 0+1 (Striping + Mirroring)

RAID 0+1 combines the performance of data striping (RAID 0) and the fault tolerance of disk mirroring (RAID 1). Data is striped across multiple drives and duplicated on another set of drives.

JBOD (Spanning)

A spanning disk array is equal to the sum of the all drives when the drives used are having different capacities. Spanning stores data onto a drive until it is full, then proceeds to store files onto the next drive in the array. When any disk member fails, the failure affects the entire array. JBOD is not really a RAID and does not support fault tolerance.

GA-K8NMF-9 Motherboard

- 64 -

Image 64
Contents GA-K8NMF-9 Motherboard Copyright Product Manual ClassificationTable of Contents Drivers Installation GA-K8NMF-9 Motherboard Layout K8NMF-9Block Diagram Page Considerations Prior to Installation Installation NoticesInstances of Non-Warranty Preparing Your ComputerFeature Summary SATA2, SATA3Bios Installation of the CPU and Fan Heat Sink Installation of the CPUInstallation of the Fan Heat Sink Installation of Memory Dual Channel Memory Configuration Installation of Expansion Cards I/O Back Panel Introduction Connectors Introduction ATX12V/ATX Power Connector Cpufan / Sysfan Cooler Fan Power Connector FDD FDD ConnectorIDE1 / IDE2 IDE Connector BAT Battery Fpanel Front Panel JumperFaudio Front Audio Panel Connector Cdin CD In ConnectorSurcen Surround Center Connector Spdifio Spdif In / Out ConnectorUSB1 / FUSB2 Front USB Connector 15 F11394 Front Ieee 1394 ConnectorsCI Chassis Intrusion, Case Open Clrcmos Clear CmosEnglish English Status Page Setup Menu / Option Page Setup Menu Main MenuMain Menu For example Bios Ver. F8 F12 For Boot Menu„ Standard Cmos Features „ Advanced Bios Features„ Power Management Setup „ PnP/PCI ConfigurationTime IDE Channel 0 Master/Slave IDE Channel 1 Master/SlaveFloppy 3 Mode Support for Japan Area IDE Channel 2/3/4/5 MasterDrive a / Drive B Halt onHard Disk Boot Priority First / Second / Third Boot DeviceBoot Up Floppy Seek Password CheckIntegrated Peripherals Init Display FirstIDE DMA transfer access On-Chip LAN Boot ROMOn-Chip IDE Channel0 On-Chip IDE Channel1IDE Prefetch Mode NV Sata 1 Primary RAIDNV Sata 1 Secondary RAID NV Sata 2 class codeNoteParallel Port Mode ECP Mode Use DMAOnboard Parallel Port On-Chip USBPower-On by Alarm PME Event Wake UpModem Ring On USB Resume from SuspendPower On by Mouse Power On by KeyboardKB Power on Password AC Back FunctionCase Opened PC Health StatusCurrent VoltageV Vcore / DDR25V / +3.3V / +12V Current CPU Temperature CPU Warning TemperatureTemp of FAN turn off Default temperature 0oC Current CPU/SYSTEM FAN Speed RPMTemp Limit of Low Speed Default temperature 20oC Temp Limit of Mid Speed Default temperature 50oCTemp Limit of High Speed Default temperature 60oC Temp of full FAN Speed Default temperature 70oCLoad Optimized Defaults Save & Exit Setup Exit Without SavingEnglish Drivers Installation Install Chipset DriversSoftware Application Software InformationHardware Information Contact UsEnglish EasyTune 5 Introduction Unique Software UtilitiesUser Interface Overview What is Xpress Recovery ? Xpress Recovery IntroductionHow to use the Xpress Recovery F9 For Xpress Recovery Remove Backup Image  Remove backup image. Are you sure? Y/N Exit and RestartMethod 1 Q-FlashTMUtility Flash Bios Method IntroductionBefore You Begin Exploring the Q-FlashTM / Dual Bios utility screen Task menu for Dual Bios utilityEntering the Q-FlashTMutility Task menu for Q-Flash utilityUsing the Q-FlashTMutility StepsYou can repeat to Part Two Exploring the Q-FlashTMutility screen EnglishCongratulation!! You have updated Bios successfully Bios file becomes F4 after updatingMethod 2 @BIOSTM Utility Methods and stepsEnglish Serial ATA Bios Setting Utility Introduction RAID LevelsConfiguring the Nvidia RAID Bios Entering the RAID Bios SetupUsing the Define a New Array Window Selecting the RAID ModeSelecting the Striping Block Size Assigning the DisksCompleting the RAID Bios Setup Array 2 Nvidia Mirror 111.79G Installing the RAID drivers Stereo Speakers Connection and Settings 5 2- / 4- / 6- / 8- Channel Audio Function IntroductionChannel Audio Setup English English English Spdif Output Device Optional Device Jack-Sensing and UAJ Introduction Introduction of audio connectorsAuto-detecting Enable UAJ function Manual settingUAJ Introduction Troubleshooting Contact Us Taiwan HeadquartersChina Shanghai