Apple G5 specifications Processor and Memory Specifications, Dimensions and Operating Environment

Page 85

Specifications

A Appendix

 

Processor and Memory Specifications

Processor

PowerPC G5 (single or dual)

256K level 2 cache

Random-access memory (RAM)

Minimum of 512 MB of DDR RAM, maximum of 8 GB of RAM in eight DIMM slots

PC3200 error-correcting (ECC), double-data-rate (DDR) Synchronous DRAM (SDRAM) (also described as DDR-400)

2.5 volt (V) unbuffered, unregistered, 64-bit wide, 184-pin module

256, 512 MB or 1 GB DIMMs (maximum number of memory devices on a DIMM is 18)

Height must not exceed 1.25 inches

Dimensions and Operating Environment

Dimensions

Height: 1.73 in. (4.4 cm) (1U)

Width: 17.6 in. (44.7 cm)

Depth: 28 in. (71.1 cm)

Weight (with three drive modules): 36.6 lb. (16.6 kg)

Note: Weight depends on the number of drive modules installed in the server.

Operating environment

Operating temperature: 10° to 35° C (50° to 95° F)

Storage temperature: –40° to 47° C (–40° to 116.6° F)

Relative humidity: 5% to 95% (noncondensing)

Altitude: 0 to 3048 meters (0 to 10,000 feet)

Optical Drive Specifications

Disk dimensions supported: 12 cm (4.7 in.)

Ethernet Specifications

IEEE 802.3 compliant

Maximum cable length: 100 meters (m)

Connectors: RJ-45 for 10Base-T, 100Base-TX, and 1000Base-T

85

Image 85
Contents User’s Guide Apple Computer, Inc Apple Computer, Inc. All rights reserved Contents Installing or Restoring Software on Your Xserve G5 System Updating or Installing Software on Xserve G5 SystemsUsing a Second Xserve G5 System to Install Server Software Starting Up From an External FireWire Optical DriveContents Page Introducing Xserve G5 Preface Introducing Xserve G5 Xserve G5 Overview Your Server at a Glance-Front Panel On/standby button and light Your Server at a Glance-Back Panel Power socket Your Server at a Glance-Interior Battery Your Cluster Node Server at a Glance Drive module and lights Your Server at a Glance-Mounting Hardware Four-post brackets Page Choose the Server’s Position in a Rack Preparing to Install Your ServerElectrical Power Rack Stability Operating EnvironmentConsiderations for Cables Security This chapter shows you how to install the server in a rack Installing Your Server in a RackGetting Ready to Install Determine the Position for the Server in the Rack There is one screw on either Side of the server Preparing the Server for InstallationInstalling Your Server in a Rack Installing Your Server in a Rack PCI-X card slots RAM slots Installing the Server in a Four-Post Rack or Cabinet Follow these steps to attach the server to the rack Some racks have Slide the brace Place the Server in the Rack Install the Cable-Management Arm and Cables Connect Cables to the Cable-Management Arm Attach the Cable-Management Arm to the Rack Remove and then reinstall the mounting screws one at a time Ethernet port Link lights Attach the Cable-Management Arm to the Support Brace It stored on the arm Clamp Shaped bracket Screw Power socket Gigabit Ethernet ports Installing Your Server in a Rack Installing the Server in a Short Four-Post Rack Some racks have Installing Your Server in a Rack Place the Server in the Rack Tighten the two thumbscrews to secure the server in the rack Installing the Server in a Two-Post Telco Rack Attach the cover to Installing Your Server in a Rack Connect Cables Directly to the Server Disconnecting Cables From the Server’s Back Panel Preparing the Server for Software Setup Starting Up the Server Using Your ServerWorking With Advanced Network Services Monitoring Status Lights and Other Indicators on the ServerSetting Up a Virtual Local Area Network Vlan Controlling Access to a Connected Keyboard and MouseEnabling Jumbo Ethernet Frames Changing the System Language Working With an Uninterruptible Power Supply UPSShutting Down the System Remotely To shut down from a network computer without Server Monitor If the Server Has a ProblemWhat to Do If Problem Try thisHard disk is erased or server Using Your Server On Xserve G5 Systems Installing or Restoring Software on Your Xserve G5 SystemTo use a second Xserve G5 system and command-line tools Using a Second Xserve G5 System to Install Server SoftwareTo start up from an external optical drive Starting Up From an External FireWire Optical DriveInstalling and Restoring From a Network Server Installing or Replacing Server Components Follow these steps to install or replace a drive module Installing or Replacing an Apple Drive ModulePress the drive module to pop out the handle Opening and Closing the Server Unscrew the two thumbscrews to release the server Pull the server out of the rack until it stops Adding Memory Follow these steps to install memory in the server Bank Installing a PCI-X Card or PCI Card Follow these steps to install a PCI-X card. or PCI card Installing a PCI-X Card or PCI CardAbout PCI-X Cards for the Server PCI-X card slots Slot covers Installing or Replacing Server Components Installing or Replacing Server Components Follow these steps to replace the lithium battery Replacing the BatteryInstalling or Replacing Server Components Dimensions and Operating Environment Processor and Memory SpecificationsOptical Drive Specifications Ethernet SpecificationsUSB Specifications FireWire SpecificationsSerial Port Specifications Power Requirements for Devices You Can Connect Power SupplySystem Clock and Battery Page Important Safety Information Safety, Maintenance,Handling Your Computer Equipment Power SupplyProtecting Your Optical Drive Cleaning the Server’s Case Cleaning Your EquipmentApple and the Environment Health-Related Information About Computer UsePage Laser Information Battery Disposal InformationHigh-Risk Activities Warning Page