Front Panel Indicator Lights continued

“BYPASS” LED: This yellow light will be lit when the UPS’s DC/AC inverter is deactivated and the UPS is in the “Bypass” mode. During normal operation this LED will light briefly when the unit is plugged in, but if an internal fault or overload occurs this light will illuminate constantly to show that connected equipment will receive filtered AC utility power, but will not receive battery power during a blackout. In this case, contact Tripp Lite for service.

“FAULT” LED: This red light will flash when your UPS detects an internal fault (overheating, overvoltages, etc.) or when it detects a wiring fault in your wall outlet (reversed phases, missing ground, etc.) The UPS will only detect wiring faults when it is plugged into a utility outlet but not turned ON. If the light persists after restarting the UPS, contact an electrician to check the AC line. Your UPS will identify the presence of most (but not all) wiring faults.

“LOAD ACTIVE METER” LED: This green light will illuminate when your UPS is receiving AC power to indicate that the set of four dual-function LEDs is displaying the load level of your UPS.

“BATT ACTIVE METER” LED: This green light will be lit when your UPS is operating from battery power to indicate that the set of four dual-function LEDs is displaying the battery charge level of your UPS. The “ON BATT” LED will also be illuminated.

“OVERLOAD” LED: This red light will be lit when your UPS’s capaci- ty has been exceeded while it is in on-line operation. The UPS alarm will beep continuously. Immediately remove overload until light and alarm go off. If you do not immediately remove the overload, the UPS will transfer from on-line to bypass operation.

“BATT LOW” LED: This yellow light will be lit when your UPS’s battery charge level is low. The UPS alarm will beep until either the battery charge is depleted or the batteries are adequately recharged.

“ON BATT” LED: This green light will be lit when AC line voltage is not present and your UPS is providing your equipment with battery power. The UPS will also beep every two seconds, unless silenced by the “ON/TEST” Switch. When this light is illuminated, you can monitor the battery charge level of your UPS on the “BATT ACTIVE METER” LEDs.

6

Image 6
Contents SmartOnline Th Street Chicago, IL 60609 USAImportant Safety Instructions UPS Location WarningsTurn your UPS on Plug your UPS into an electrical outletPlug your equipment into your UPS Connection and Start-UpExternal Battery Pack Connection Serial Port ConnectionImportantBasicOperationSafety Instructions Front Panel SwitchesFront Panel Indicator Lights Basic Operation Rear Panel Communications ON/Test Switch Basic Operation Restart the UPS. If the problem persistsThis indicates that utility power is too high Or low for the UPS to operate in BypassService StorageManual del usuario Th Street Chicago, IL 60609 EE.UUImportantes instrucciones de seguridad Guarde Estas InstruccionesConecte su UPS en un tomacorriente Enchufe su equipo al sistema UPSConexión y encendido Conexión de puerto serial Instalación opcionalEncienda su sistema UPS on Conexión del paquete de baterías externasInterruptores del panel frontal Luces indicadoras del panel frontalOperación básica continuación Luces indicadoras del panel frontal continuaciónPanel posterior Panel posterior continuación ComunicacionesCondición Batería baja Condición Reemplazar bateríaEncendidas Batería BAJA, EN Batería Encendidas DERIVACIÓN, LÍNEA, CargaLocalización de fallas continuación Encendidas DERIVACIÓN, LíneaAlmacenamiento Almacenamiento y servicio continuación ServicioNota sobre el rotulado Guide de lutilisateur Th Street, Chicago, IL 60609 USAImportantes consignes de sécurité Conservez CES Instructions EN UN Lieu SÛRBranchez votre ASI dans une prise de courant électrique Branchez votre matériel dans votre système UPSConnexion et démarrage Mettez votre système UPS en marche Installation suiteInstallation optionnelle Connexion de port sérieImExploitationortantSafdetybaseInstructions Commutateurs du panneau avantVoyants du panneau avant Exploitation de base suite Voyants du panneau avant suitePanneau arrière Panneau arrière suite Problème Remplacez la batterie Problème persiste, consultez leDépannage suite Le système UPSEntreposage EntretienPage Page 200602179

SUINT1000XL, SUINT3000XL, SUINT2000XL specifications

Tripp Lite’s SUINT series of uninterruptible power supply (UPS) systems—specifically the SUINT1000XL, SUINT2000XL, and SUINT3000XL—are designed to provide reliable backup power protection for sensitive electronics and critical equipment in various settings, from home offices to data centers.

Each model in the SUINT series boasts a robust Pure Sine Wave output, which ensures that connected devices receive clean and stable power. This is particularly important for equipment sensitive to voltage fluctuations, helping to prevent damage and malfunction. The pure sine wave output mimics the electrical waveform of utility power, making these UPS systems suitable for a variety of devices, including computers, networking equipment, and even certain audio/video devices.

One of the key features of the SUINT series is its extended runtime capabilities. Users can select interchangeable external battery packs for additional runtime, making these UPS systems versatile for longer outages. The SUINT1000XL provides up to 1000VA capacity, while the SUINT2000XL and SUINT3000XL offer 2000VA and 3000VA of capacity, respectively. This flexibility allows users to choose the model that best meets their power requirements.

All three models feature an LCD display that provides real-time monitoring of vital UPS functions, including battery status, load level, and estimated runtime. This user-friendly interface allows for prompt assessment of power conditions and easy navigation through settings and configurations.

In addition, the SUINT series includes automatic voltage regulation (AVR) technology to stabilize output voltage, ensuring that your equipment receives consistent power despite fluctuations in the input voltage. This technology is crucial in areas with unreliable power supply, enhancing the reliability of the UPS.

The SUINT series also emphasizes communication and adaptability. With USB and serial ports for connection to a computer, users can monitor the UPS status via software. This allows for scheduled shutdowns and monitoring under critical conditions, enhancing the overall safety and efficiency of the connected devices.

Compatibility with Tripp Lite's PowerAlert software enables advanced power management features, ensuring that users can manage their system for optimal performance.

Overall, the Tripp Lite SUINT1000XL, SUINT2000XL, and SUINT3000XL are robust UPS solutions, providing necessary power protection, user-friendly features, and advanced technologies to keep critical equipment running smoothly during power disturbances. Their combination of pure sine wave output, extended runtime, AVR technology, and communication capabilities make them essential for safeguarding sensitive electronics.