Schneider Electric TSXCUSBMBP Installation Requirements, Upgrading From Previous Version

Page 16

Installation

Installation Requirements

Installation

Installation requirements are as follows:

Requirements

z Microsoft Windows XP Operating System with Service Pack 2 or greater installed

list

(Windows 2000 with Service Pack 4 or greater can also be used on most

 

computers),

 

z 1 MB free disk space,

 

z at least 256 MB RAM,

 

z at least one free USB port or a USB Hub supporting USB 1.1 or greater.

 

 

Upgrading From Previous Version

Introduction

Currently, if a previous version of the TSXCUSBMBP Driver has been installed, the

 

Virtual Serial Port component of the driver must be manually uninstalled using

 

Device Manager before a new version can be installed.

How to uninstall the Virtual Serial Port?

These steps must be followed to uninstall the Virtual Serial Port from your system.

Step Action

1Close any software applications using the TSXCUSBMBP Driver.

2Exit the TSXCUSBMBP Driver by right clicking on the Icon at the bottom then selecting Exit Driver.

3Unplug the USB Modbus Plus Device from the USB port on the computer (or USB Hub if using one).

4Start up the Windows Device Manager.

On most systems, this is done by the following steps.

z Open Control Panel, System, Hardware, then Device Manager.

z In Device Manager, left click on the + next to ABT Virtual Device. Virtual Serial Port will now appear underneath ABT Virtual Device.

z Right click on Virtual Serial Port and select Uninstall. z When prompted, confirm the device removal.

z After ABT Virtual Device disappears from the list, close the Device Manager.

16

35011984 02/2006

Image 16
Contents Tsxcusbmbp Page Table of Contents Connecting to a Modbus Plus Network Using the Tsxcusbmbp with an ApplicationModbus Plus Network Diagnostic Functions Appendix a Tsxcusbmbp Settings for UnitySafety Information Important InformationSchneider Electric. All Rights Reserved About the Book At a GlanceAbout the Book Introduction Glossary Abbreviations Acronyms Glossary of Abbreviations AcronymsAbbreviation/Acronym Expansion Abbreviations & Acronyms Subject of this chapter Whats in this Chapter? OverviewTopic Modbus Plus Communication for Applications IntroductionVirtual Serial Port VSPTsxcusbmbp Hardware Modbus Plus Network DiagnosticsDescription Overview Subject of this InstallationChapter? Installation Requirements Upgrading From Previous VersionInstalling the Tsxcusbmbp Hardware Installing the Tsxcusbmbp Driver SoftwareIntroduction How to install Tsxcusbmbp Driver? How to install Tsxcusbmbp Hardware Establishing a Connection to StatusDriver Icon Color Status of the driverHow to rescan? Rescan AdaptersShow Interface If the iconConfiguring the Tsxcusbmbp Driver Tsxcusbmbp Driver Interface Window InterfaceWindow Display Select Show InterfaceAddress Configuring the Modbus Plus Node AddressAddress Changing Process Timeout Configuring the Slave Response TimeoutSlave Response Configuration Configured as follows Assignment Configuring the Virtual Serial COM PortThen Configuring the Modbus Plus Routing ConfiguringAddressing MethodsDirect ExplicitImplicit Routing Example Routing example Modbus + Slave IDModbus Plus Routing Path Node Used by Routing Table Address Application EntryTsxcusbmbp Entering Routing Paths into the Routing Table Configuring the Tsxcusbmbp Driver Connecting to a Modbus Plus Network Modbus Plus Network Status IndicatorFlash Codes LED Flash Code DescriptionConnecting to a Modbus Plus Network Using the Tsxcusbmbp with an Application Tsxcusbmbp with an Application Whats in this Chapter?Start the Tsxcusbmbp Driver Introduction Typical Configuration Configure the Application SoftwareConnect Using the Tsxcusbmbp with an Application Modbus Plus Network Diagnostic Functions Section TopicModbus Plus Network Diagnostic Functions Starting the Diagnostic Functions Procedure for Starting the Diagnostic FunctionsScanning the Modbus Plus Network Procedure for Scanning the Modbus Plus NetworkScanning Local or Complete Network Displaying Diagnostic Information Introduction Whats in this Section?Procedure for Displaying Diagnostic Information Modbus Plus Network Diagnostics screenProcedure ResultsNode Error Statistics Node Personality ScreennodeInternal Path Transactions Transactions Selected node ScreenScreen Green when active and gray when inactive Token Owner Work TableMap screen. This section describes this screen Node TokenActive Station Table Token Station Table Global Data Present Table Present TableRead Global Data Global DataModbus Plus Network Diagnostic Functions Appendices Introduction Whats in this Appendix?Appendices Tsxcusbmbp Settings for Unity Tsxcusbmbp Settings for UnityThis situation from occurring Configuring Unity Make sure both drivers are running You should now be able to Connect Tsxcusbmbp Settings for Concept & ProWORX32 SettingConfiguring Concept ProWORX32 TsxcusbmbpStep Action