Installation

Installing the TSXCUSBMBP Driver Software

Introduction

How to install the

TSXCUSBMBP Driver?

The TSXCUSBMBP Driver must be installed before connecting the TSXCUSBMBP device to the USB port.

Use the following procedure to install the Driver software.

Step Action

1Insert the CD-ROM labeled TSXCUSBMBP Driver into your CD-ROM drive.

2The installation should begin automatically. If not, follow the procedure below to start the installation manually.

z From the Start menu (Start button on Windows XP task bar), select Run

z Type in D:\Setup.exe (if your CD-ROM drive is not D:, substitute the drive letter of your CD-ROM drive) and press Ok.

3Follow the on-screen instructions to complete the software installation.

4The final step of the software installation will display a message window containing instructions. Please read the instructions carefully.

Installing the TSXCUSBMBP Hardware

Introduction The TSX C USB MBP can be connected directly to a USB port on the PC or through a USB Hub. The TSXCUSBMBP acquires power from the USB port or Hub, therefore no power connection is required.

Note: Do not connect the Modbus Plus network cable to the Modbus Plus port on the TSXCUSBMBP until after the Modbus Plus Node Address has been configured in the Driver Software. This will avoid the potential for duplicate Modbus Plus node addresses on your network.

35011984 02/2006

17

Image 17
Contents Tsxcusbmbp Page Table of Contents Using the Tsxcusbmbp with an Application Connecting to a Modbus Plus NetworkModbus Plus Network Diagnostic Functions Appendix a Tsxcusbmbp Settings for UnityImportant Information Safety InformationSchneider Electric. All Rights Reserved At a Glance About the BookAbout the Book Abbreviation/Acronym Expansion Glossary of Abbreviations AcronymsIntroduction Glossary Abbreviations Acronyms Abbreviations & Acronyms Topic OverviewSubject of this chapter Whats in this Chapter? Introduction Modbus Plus Communication for ApplicationsVirtual Serial Port VSPDescription Modbus Plus Network DiagnosticsTsxcusbmbp Hardware Overview Chapter? InstallationSubject of this Upgrading From Previous Version Installation RequirementsIntroduction How to install Tsxcusbmbp Driver? Installing the Tsxcusbmbp Driver SoftwareInstalling the Tsxcusbmbp Hardware How to install Tsxcusbmbp Hardware Status Establishing a Connection toDriver Icon Color Status of the driverRescan Adapters How to rescan?Show Interface If the iconConfiguring the Tsxcusbmbp Driver Interface Tsxcusbmbp Driver Interface WindowWindow Display Select Show InterfaceAddress Changing Process Configuring the Modbus Plus Node AddressAddress Slave Response Configuring the Slave Response TimeoutTimeout Configuration Configured as follows Then Configuring the Virtual Serial COM PortAssignment Configuring Configuring the Modbus Plus RoutingAddressing MethodsImplicit ExplicitDirect Modbus + Slave ID Routing Example Routing exampleModbus Plus Routing Path Node Used by Routing Table Address Application EntryTsxcusbmbp Entering Routing Paths into the Routing Table Configuring the Tsxcusbmbp Driver Modbus Plus Network Status Indicator Connecting to a Modbus Plus NetworkFlash Codes LED Flash Code DescriptionConnecting to a Modbus Plus Network Tsxcusbmbp with an Application Whats in this Chapter? Using the Tsxcusbmbp with an ApplicationStart the Tsxcusbmbp Driver Connect Configure the Application SoftwareIntroduction Typical Configuration Using the Tsxcusbmbp with an Application Section Topic Modbus Plus Network Diagnostic FunctionsModbus Plus Network Diagnostic Functions Procedure for Starting the Diagnostic Functions Starting the Diagnostic FunctionsScanning Local or Complete Network Procedure for Scanning the Modbus Plus NetworkScanning the Modbus Plus Network Introduction Whats in this Section? Displaying Diagnostic InformationModbus Plus Network Diagnostics screen Procedure for Displaying Diagnostic InformationResults ProcedureNode Error Statistics Screennode Node PersonalityTransactions Selected node Screen Internal Path TransactionsToken Owner Work Table Screen Green when active and gray when inactiveMap screen. This section describes this screen Node TokenActive Station Table Token Station Table Present Table Global Data Present TableGlobal Data Read Global DataModbus Plus Network Diagnostic Functions Introduction Whats in this Appendix? AppendicesAppendices This situation from occurring Tsxcusbmbp Settings for UnityTsxcusbmbp Settings for Unity Configuring Unity Make sure both drivers are running You should now be able to Connect Setting Tsxcusbmbp Settings for Concept & ProWORX32Tsxcusbmbp Configuring Concept ProWORX32Step Action