TSXCUSBMBP Settings for Unity

TSXCUSBMBP Settings for Unity

A

Introduction

This section describes how to configure Unity to work the TSXCUSBMBP.

Important

 

If the serial Modbus driver for Unity comes up before the TSXCUSBMBP driver

Information

during system startup, Unity will not work properly. The following steps will prevent

 

this situation from occurring:

Step Action

1Close the Unity application if it is open.

2Shut down Unity's serial Modbus driver by right-clicking on the Modbus driver's icon in the system tray then selecting Close.

3Start the Unity application. Unity will automatically restart its serial Modbus driver.

35011984 02/2006

57

Image 57
Contents Tsxcusbmbp Page Table of Contents Using the Tsxcusbmbp with an Application Connecting to a Modbus Plus NetworkModbus Plus Network Diagnostic Functions Appendix a Tsxcusbmbp Settings for UnityImportant Information Safety InformationSchneider Electric. All Rights Reserved At a Glance About the BookAbout the Book Glossary of Abbreviations Acronyms Introduction Glossary Abbreviations AcronymsAbbreviation/Acronym Expansion Abbreviations & Acronyms Overview Subject of this chapter Whats in this Chapter?Topic Introduction Modbus Plus Communication for ApplicationsVirtual Serial Port VSPModbus Plus Network Diagnostics Tsxcusbmbp HardwareDescription Overview Installation Subject of thisChapter? Upgrading From Previous Version Installation RequirementsInstalling the Tsxcusbmbp Driver Software Installing the Tsxcusbmbp HardwareIntroduction How to install Tsxcusbmbp Driver? How to install Tsxcusbmbp Hardware Status Establishing a Connection toDriver Icon Color Status of the driverRescan Adapters How to rescan?Show Interface If the iconConfiguring the Tsxcusbmbp Driver Interface Tsxcusbmbp Driver Interface WindowWindow Display Select Show InterfaceConfiguring the Modbus Plus Node Address AddressAddress Changing Process Configuring the Slave Response Timeout TimeoutSlave Response Configuration Configured as follows Configuring the Virtual Serial COM Port AssignmentThen Configuring Configuring the Modbus Plus RoutingAddressing MethodsExplicit DirectImplicit Modbus + Slave ID Routing Example Routing exampleModbus Plus Routing Path Node Used by Routing Table Address Application EntryTsxcusbmbp Entering Routing Paths into the Routing Table Configuring the Tsxcusbmbp Driver Modbus Plus Network Status Indicator Connecting to a Modbus Plus NetworkFlash Codes LED Flash Code DescriptionConnecting to a Modbus Plus Network Tsxcusbmbp with an Application Whats in this Chapter? Using the Tsxcusbmbp with an ApplicationStart the Tsxcusbmbp Driver Configure the Application Software Introduction Typical ConfigurationConnect Using the Tsxcusbmbp with an Application Section Topic Modbus Plus Network Diagnostic FunctionsModbus Plus Network Diagnostic Functions Procedure for Starting the Diagnostic Functions Starting the Diagnostic FunctionsProcedure for Scanning the Modbus Plus Network Scanning the Modbus Plus NetworkScanning Local or Complete Network Introduction Whats in this Section? Displaying Diagnostic InformationModbus Plus Network Diagnostics screen Procedure for Displaying Diagnostic InformationResults ProcedureNode Error Statistics Screennode Node PersonalityTransactions Selected node Screen Internal Path TransactionsToken Owner Work Table Screen Green when active and gray when inactiveMap screen. This section describes this screen Node TokenActive Station Table Token Station Table Present Table Global Data Present TableGlobal Data Read Global DataModbus Plus Network Diagnostic Functions Introduction Whats in this Appendix? AppendicesAppendices Tsxcusbmbp Settings for Unity Tsxcusbmbp Settings for UnityThis situation from occurring Configuring Unity Make sure both drivers are running You should now be able to Connect Setting Tsxcusbmbp Settings for Concept & ProWORX32Tsxcusbmbp Configuring Concept ProWORX32Step Action