Schneider Electric TSXCUSBMBP user manual Displaying Diagnostic Information

Page 43

Modbus Plus Network Diagnostic Functions

8.3Displaying Diagnostic Information

At a Glance

Introduction

What's in this Section?

This section describes the diagnostic information that can be displayed for each node.

This section contains the following topics:

Topic

Page

 

 

Procedure for Displaying Diagnostic Information

44

 

 

Node Error Statistics

46

 

 

Node Personality

47

 

 

Internal Path Transactions

48

 

 

Token Owner Work Table

49

 

 

Active Station Table

50

 

 

Token Station Table

51

 

 

Global Data Present Table

52

 

 

Read Global Data

53

 

 

 

 

35011984 02/2006

43

Image 43
Contents Tsxcusbmbp Page Table of Contents Appendix a Tsxcusbmbp Settings for Unity Connecting to a Modbus Plus NetworkUsing the Tsxcusbmbp with an Application Modbus Plus Network Diagnostic FunctionsImportant Information Safety InformationSchneider Electric. All Rights Reserved At a Glance About the BookAbout the Book Introduction Glossary Abbreviations Acronyms Glossary of Abbreviations AcronymsAbbreviation/Acronym Expansion Abbreviations & Acronyms Subject of this chapter Whats in this Chapter? OverviewTopic Port VSP Modbus Plus Communication for ApplicationsIntroduction Virtual SerialTsxcusbmbp Hardware Modbus Plus Network DiagnosticsDescription Overview Subject of this InstallationChapter? Upgrading From Previous Version Installation RequirementsInstalling the Tsxcusbmbp Hardware Installing the Tsxcusbmbp Driver SoftwareIntroduction How to install Tsxcusbmbp Driver? How to install Tsxcusbmbp Hardware Icon Color Status of the driver Establishing a Connection toStatus DriverIf the icon How to rescan?Rescan Adapters Show InterfaceConfiguring the Tsxcusbmbp Driver Select Show Interface Tsxcusbmbp Driver Interface WindowInterface Window DisplayAddress Configuring the Modbus Plus Node AddressAddress Changing Process Timeout Configuring the Slave Response TimeoutSlave Response Configuration Configured as follows Assignment Configuring the Virtual Serial COM PortThen Methods Configuring the Modbus Plus RoutingConfiguring AddressingDirect ExplicitImplicit Node Used by Routing Table Address Application Entry Routing Example Routing exampleModbus + Slave ID Modbus Plus Routing PathTsxcusbmbp Entering Routing Paths into the Routing Table Configuring the Tsxcusbmbp Driver LED Flash Code Description Connecting to a Modbus Plus NetworkModbus Plus Network Status Indicator Flash CodesConnecting to a Modbus Plus Network Tsxcusbmbp with an Application Whats in this Chapter? Using the Tsxcusbmbp with an ApplicationStart the Tsxcusbmbp Driver Introduction Typical Configuration Configure the Application SoftwareConnect Using the Tsxcusbmbp with an Application Section Topic Modbus Plus Network Diagnostic FunctionsModbus Plus Network Diagnostic Functions Procedure for Starting the Diagnostic Functions Starting the Diagnostic FunctionsScanning the Modbus Plus Network Procedure for Scanning the Modbus Plus NetworkScanning Local or Complete Network Introduction Whats in this Section? Displaying Diagnostic InformationModbus Plus Network Diagnostics screen Procedure for Displaying Diagnostic InformationResults ProcedureNode Error Statistics Screennode Node PersonalityTransactions Selected node Screen Internal Path TransactionsNode Token Screen Green when active and gray when inactiveToken Owner Work Table Map screen. This section describes this screenActive Station Table Token Station Table Present Table Global Data Present TableGlobal Data Read Global DataModbus Plus Network Diagnostic Functions Introduction Whats in this Appendix? AppendicesAppendices Tsxcusbmbp Settings for Unity Tsxcusbmbp Settings for UnityThis situation from occurring Configuring Unity Make sure both drivers are running You should now be able to Connect Setting Tsxcusbmbp Settings for Concept & ProWORX32Tsxcusbmbp Configuring Concept ProWORX32Step Action