Moxa Technologies user manual CP-102U/UL User’s Manual Software Installation

Page 51

CP-102U/UL User’s Manual

Software Installation

4.Select a COM number for the port from the Port Number pull-down list.

5.Check the Auto Enumerating COM Number checkbox to map subsequent ports automatically. The port numbers will be assigned in sequence. For example, if COM3 is assigned to Port 1, then COM4 (if not already occupied) will be assigned to Port 2, etc.

6.Select an Rx FIFO Trigger from the Rx FIFO Level pull-down list. Rx FIFO trigger levels of High, Middle, and Low are available, with the default set to High (120 bytes). Check Set the change to all ports checkbox to apply this Rx FIFO Trigger to all ports.

7.Select a Tx FIFO Level from the Tx FIFO Level pull-down list. Tx FIFO Levels of High, Middle, and Low are available, with the default set to High (128 bytes). Check Set the change to all ports checkbox to apply the just defined Tx FIFO Size to all ports.

 

CP-102U/UL

 

Tx FIFO

Rx FIFO

High

128

120

Middle

64

60

Low

1

1

Unit: Bytes

3-39

Image 51
Contents CP-102U/UL User’s Manual Copyright Notice TrademarksDisclaimer Table of Contents Page Introduction Overview Smartio-The Smart Multiport Async SolutionFeatures Package ChecklistApplications Installation Flowchart Hardware Installation Block Diagrams CP-102UCP-102UL Plugging the Board into an Expansion Slot Page Software Installation CPCI Boards CT-114I Windows DriversWindows 2003/XP Installing the DriverCP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation Configuring the Ports CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation Using Event Log Using Moxa PComm UtilityRemoving the Driver Windows Installing the Driver for the First TimeCP-102U/UL User’s Manual Software Installation Select Specify a location and then click on Next to continue CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation Configuring the Ports CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation Using Moxa PComm Utility Removing the Driver Windows 95/98 CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation Configuring the Ports CP-102U/UL User’s Manual Software Installation Updating the Driver CP-102U/UL User’s Manual Software Installation Click on Next Removing the Driver CP-102U/UL User’s Manual Software Installation Windows NT Continue from in the next section, Configuring the Ports CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation Removing a CP-102U/UL Board Click on Remove Click on Close, and then restart the system DOS Non-Windows DriversRun BIN\SETUP.EXE Setting up the DriverTxD buffer size Unloading the Driver Loading the DriverLinux Execute the following commands from the Linux promptSCO CP-102U/UL User’s Manual Software Installation CP-102U/UL User’s Manual Software Installation Utilities Serial Programming ToolsInstalling PComm Moxa PCommPComm Programming Library Utilities Diagnostic for Moxa boards onlyMonitor for Moxa boards under Windows NT/2000/XP/2003 Terminal Emulator Page Pin Assignments Male DB9 Connector CP-102U & CBL-M25M9x2-50 Female DB25 Connector CP-102ULGeneral Troubleshooting TroubleshootingWindows 95/98 Windows NTTechnical Reference Product SpecificationsPCI Service Information Following services are provided Moxa Internet ServicesMoxa CP-102U/UL Series Problem Report FormProduct Return Procedure