Pelco CM6800E-48X8 manual Multiple M Devices Remote Connection

Page 30

Multiple M Devices: Remote Connection

Use a remote connection when the distance from the CM6800E is greater than 6-feet (1.8 m).

1.Connect each ALM2064 and REL2064 unit to a wall block with a 6-foot (1.8 m) straight cable (supplied with the CM6800E). You can connect a maximum of four ALM2064 units and four REL2064 units to the CM6800E.

2.If you are connecting a KBD960, connect it to the CM9505UPS with the straight cable supplied with the keyboard. Then connect the CM9505UPS to a wall block with a 6-foot (1.8 m) straight cable (supplied with the CM6800E). You can connect a maximum of two KBD960 keyboards to the CM6800E.

3.Connect the wall blocks to a final wall block. If additional wall blocks are needed, order part number CON12J008Z03G0Z.

4.Connect the terminal wall block to COM 3 on the CM6800E using a 6-foot (1.8 m) straight cable (supplied with the CM6800E).

 

 

 

010101

 

 

1

5

 

 

2

6

31

32

3

7

 

4

4

8

 

 

 

7

8

 

 

STRAIGHT CABLE (SUPPLIED)

RS-485

1 2 3 4 5 6 7 8

 

 

CONTROL

 

A T

T

R R

T

T

R R B

+

-

- +

+

-

- +

 

 

 

 

 

F

 

1

 

2

 

3

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

120/230~

 

 

 

 

 

50/60 HZ

 

 

 

 

 

25 WATTS

CM6800E-48X8 COM 3

DEFAULT SETTINGS:

M, RS-485, 19200 BAUD, NO PARITY, 8 DATA BITS, 1 STOP BIT MAXIMUM DISTANCE FROM CM6800 = 3,940 FT (1,200 M)

USING 24 AWG COPPER, UNSHIELDED TWISTED PAIR, 16pF PER FT (pF = PICOFARADS)

CM6800E-48X8 COM 3

RJ-45 PIN-OUTS

1Rx+

2RX-

5GND

7Tx-

8Tx+

KBD960

STRAIGHT CABLE

TO CM9505PS

(SUPPLIED)

KBD960

RJ-45 PIN-OUTS

1Tx+

2TX-

7Rx-

8Rx+

 

 

 

STRAIGHT CABLE

 

 

 

 

 

(SUPPLIED)

 

 

ALM2064

 

 

REL2064

 

 

CONNECT THROUGH

 

 

CONNECT THROUGH

REL2064

THE "OUT" PORT

ALM2064

THE "OUT" PORT

 

 

RJ-45 PIN-OUTS

 

RJ-45 PIN-OUTS

 

1

Tx+

 

1

Tx+

 

 

 

2

TX-

 

2

TX-

 

 

 

3

 

 

3

 

 

 

 

 

 

4

 

 

4

 

 

 

 

 

 

5

 

 

5

 

 

 

 

 

 

6

 

 

6

 

 

 

 

 

 

7

Rx-

 

7

Rx-

 

 

 

8

Rx+

 

8

Rx+

 

 

 

 

 

Figure 22. Connecting Multiple M Devices – Remote Connection

30

C1528M-F (6/05)

Image 30
Contents CM6800E-48X8 Contents Control Genex Multiplexer and Genex Multiplexer Displays List of Illustrations List of Tables C1528M-F 6/05 Important Safeguards and Warnings For Qualified Service Personnel onlyDescription Sample CM6800E-48X8 SystemSample CM6800E 96 x 16 System Programming Sequences, Macros, Presets, Patterns, and ZonesSystem Access and Priority KeyboardsAuxiliary Outputs Alarm InputsPower, Mounting Methods Continuous Operating DeviceAdditional Resources ModelsCompatible Products Associated EquipmentInstallation MountingCable Type Maximum Distance 96 x 16 System Default Camera NumbersVideo Sources Main unit Cameras Expansion unit CamerasConnecting Looping Video Sources Control Lines 96 x 16 System PTZ Control CapacityMonitors 96 x 16 System Monitor CapacityMain unit Monitor Expansion Unit Monitor Alarms 96 x 16 System Alarm CapacityMain unit Alarms Expansion Unit Alarms Connecting Devices Through the Communication Ports Input Type Wiring Pin-Outs Default DeviceCM9760-MDA, Ascii Port RS-485 Pin-Outs Ascii device CM9760-MDA, Satellite Rx+Ground Tx+ RS-232 Pin-Outs RJ-45 RS-485, 19200 baud, no parity, 8 data bits, 1 stop bitCM6800E Communication Port Connections and Options KBD100, KBD200A, and KBD300A Direct-Powered Keyboards KBD100, KBD200A, and KBD300A Series KeyboardsKeyboard Switch Keyboard Address Switch SettingsTable E. Switch Settings-KBD200A/300A Keyboards Only OFFKBD100, KBD200A, and KBD300A Remote Keyboards Remote KeyboardsDevices KBD960, ALM2064, REL2064 Devices AddressingKBD960/KBR960 REL2064 ALM2064 Connecting a Single KBD960/KBR960 Keyboard Connecting a KBD960/KBR960 to the CM6800EConnecting a Single ALM2064 Alarm Interface Unit To connect a single ALM2064 Alarm Interface UnitConnecting a Single REL2064 Relay Interface Unit To connect a single REL2064 Relay Interface UnitMultiple M Devices Multiple M Devices Local ConnectionConnecting Multiple M Devices Remote Connection Multiple M Devices Remote ConnectionConnecting a PC PC Connection to RJ-45 PortConnecting Genex Multiplexers Connecting Genex Multiplexers96 x 16 System Auxiliary Capacity Connecting Relay Contacts AUX 1Local Auxiliaries Main unit AUX Expansion Unit AUXConnecting the Open Collector Output F3 TTL Wiring the F3 TTL OutputConnecting a 96 X 16 System CM6800E-48X8 Main UnitPOWER-UP the System System START-UPInitialize Keyboards Communication Ports Configure the SystemPort Default Settings COMGenex Multiplexer 96 X 16 System SettingsKBD960/KBR960 Keyboard Control MUXMonitor Color Adjustment Program PresetsAdditional Programming Programming the CM6800E CM6800E Programming Mode Exit Programming ModeSelect Language Entries in Programming Mode FunctionKeyboard Navigate to the Help field Press F1 Navigate to the Next or Previous field Press F1Camera to Keyboard AccessKeyboard to Monitor Camera to MonitorAlarm Programming Program Alarm GroupsProgram AN Internal or External Alarm Contact Type AUX field, select an auxiliary to be activatedACK Type PriorityProgram a Video Loss Alarm Program Video Loss AlarmsAssign a Logical Alarm Number Optional Assign a Logical Alarm NumberAuxiliary Outputs Alarm-based OperationMode field for each auxiliary, select either LAT or MOM Latching or Momentary OperationCamera Programming Program Logical NumbersIf necessary, first program logical camera number Program Cameras Program Vertical Drive Option Optional Select CharacterEvent Timers Macros Macro Status View ScreenCamera Title Monitor DisplayMonitor Type Display ValuesTime Monitor Status Display ValuesALM Status Display Values DatePassword Use the Set Password screen to change the system passwordPorts SERIAL/COM Ports Serial Port Input on CM6800E rear panelAction Ascii text Options PriorityPort Level 1 = highest priority Level 8 = lowest priority96 X 16 System Settings Change the System SettingSequences SequenceTurn global auxiliary off AUX and ##Turn global auxiliary on Turn camera auxiliary onPATTERNS, PRESETS, and Zones Time and DateOptions DD/MMM/YY MMM/DD/YY YY/MMM/DD DD/MM/YY YY/MM/DD Overview Switch MonitorsOperation Operating the CM6800EControl Receivers Operate Sequences To move through the sequence one camera at a timeRUN a Macro Select Macro to start the macroSelect To start the macro Acknowledge AN Alarm Call a PresetCreate and RUN a Pattern Patterns are not available with the KBD100 keyboardOperate an External Auxiliary Operate AUXILIARIES/RELAYSOperate a Local Auxiliary Operate an Auxiliary in a ReceiverDetect Video Loss Control Genex Multiplexer and Genex Multiplexer DisplaysOperate Scanning Functions Define ZonesSwitch CM6800E DIP SwitchesCM6800E DIP Switch Default Setting AppendixBlock Build Alarm Group Display OptionsMonitor Alarm Alarms Chronological Pair D and QMonitor Alarm Alarms Next Display Cycle Reverse Chronological Pair M and LSalvo Group Macro Commands Description Specify FieldsAuxiliary Notes Nano PipoQuad HEXInstall the CM6800E AS a Satellite Device Page Configure the CM6800E AS a Satellite Device Satellite Monitor AccessSatellite Port Settings Change the Port SettingSatellite Alarms Optional Enable Alarm ContactsConfigure CM9700-MGR System Manager Settings Add a Satellite Device in the CM9700-MGRConfigure CM9760-MGR System Manager Settings Program the Comms File Click the Comms tab. The Comms page appearsProgram the Cameras File Click the Cameras tab. The Cameras page appearsProgram the Link Cameras File Click the Link Cameras tab. The Link Cameras page appearsProgram the Alarms File Optional Click the Alarms tab. The Alarms page appearsClick OK to close the Alarm Camera Switches dialog box How to Select a Numerical Value in an Option Field How to Display the CM6800E Programming Main MenuHow to Exit Programming Mode Press 89 PresetLogical Number Assignment Table for Link Cameras Link Camera NameLink Camera page Phy Num column Ascii Operating Commands Functional Procedure Commands Result3Ma16#a Desired Action Command Result Uppercase charactersAcknowledge an alarm #Ka Panel An alarm is triggered #Ea 48~Jva Trigger an alarm #EaClear an alarm #Ia Logical Alarm Number in the Alarm Programming sectionTroubleshooting Gaining Initial ControlWait AT Least Five Seconds Software Reset Dip Switch Cover PlateSolutions to Common Problems Problem RemedyKBD960/KBR960 ICON/BUTTON Legend Icon/Button LegendUpgrade the CM6800 Switcher Software Upgrade the CM6800 Switcher SoftwareGlossary Term DefinitionAscii Ntsc PALPTZ RS-422 All four wiresStar configuration Recommended distance is 4,000 feet 1,219 mSpecifications Regulatory Notices 48 x 8 System96 x 16 System Product Warranty and Return Information C1528M-F 6/05 105 ISO9001