CONTROL GENEX MULTIPLEXER AND GENEX MULTIPLEXER DISPLAYS

Multiplexer control is not available with the KBD100.

KBD200A/300A KEYBOARDS

KBD960/KBR960 KEYBOARDS

 

 

 

 

 

 

 

 

 

1. Enter the number of the multiplexer input.

1.

Enter a MUX input number and press

 

. Each MUX

 

 

2. Press the CAM key.

 

input is associated with a camera input. Figure 43

3. Press the SHIFT key. When the SHIFT LED is lit, the keyboard can

 

shows MUX 1 being controlled.

 

 

 

 

 

 

 

 

be used to operate the following Genex multiplexer function keys:

2.

Select MUX . MUX Menu 1 appears. MUX

should be

F1: Digital zoom

 

highlighted, which means you have MUX control.

 

 

 

 

 

 

F2: PIP display

3.

Cycle through the 16 picture inserts (if you have a

F3: Quad display

 

16-channel multiplexer) by entering the camera number

AUX ON/F4: 9-screen display

 

and selecting

.

 

 

AUX OFF/F5: 16-screen display

 

 

 

 

 

 

 

 

 

To select a camera through the multiplexer:

4.

Select

again to zoom into the MUX camera. You

 

can move the joystick to view a specific area.

a. Enter the desired camera number (1-16, based on the camera

 

5.

Select

to bring up MUX Menu 2. The icons for a

assignments set through the multiplexer).

b. Press the CAM key.

 

picture-in-picture display, 4-camera display, 9-camera

 

display, and 16-camera display appear.

 

 

 

 

4. Press the SHIFT key to return to normal keyboard operation.

6.

Select

to view four of the available 16 cameras on

When the SHIFT LED is off, you can control the currently selected

 

one monitor. You can cycle through all 16 cameras, four

PTZ camera through the multiplexer.

 

at a time, by repeatedly selecting

.

 

To return to camera selection controlled by the CM6800E:

 

 

7.

Select

to view nine of the available 16 cameras on

a. Select the desired camera number.

 

one monitor. Select again to see the remaining seven

b. Press the CAM key.

 

cameras.

 

 

 

 

c. Move the joystick as necessary.

8.

Select

to view all 16 available cameras on one

 

 

 

monitor.

 

 

 

 

 

 

Note that

 

does not work on a 9-channel

 

 

mulitplexer.

 

 

 

 

 

 

 

 

 

 

 

OPERATE SCANNING FUNCTIONS

Operation of the scanning functions depends on the kind of receiver or pan/tilt mechanism you have. Refer to the appropriate keyboard manual for detailed instructions on operating scanning functions.

DETECT VIDEO LOSS

The CM6800E detects video loss from any system camera. If video is lost from a camera, the CM6800E blue screen appears on any monitor viewing that camera. When video is restored to that camera, the camera view appears on the monitor(s) again. If the system is programmed for a video loss alarm, the alarm icon appears.

DEFINE ZONES

A zone is a user-defined, physical location to which (1) a label is attached and (2) a camera is associated. When the associated camera is panned through or remains within this defined zone the zone label appears on the monitor.

Refer to the appropriate keyboard manual for detailed instructions on defining zones.

72

C1528M-F (6/05)

Image 72
Contents CM6800E-48X8 Contents Control Genex Multiplexer and Genex Multiplexer Displays List of Illustrations List of Tables C1528M-F 6/05 Important Safeguards and Warnings For Qualified Service Personnel onlyDescription Sample CM6800E-48X8 SystemSample CM6800E 96 x 16 System Sequences, Macros, Presets, Patterns, and Zones System Access and PriorityProgramming KeyboardsAlarm Inputs Power, Mounting MethodsAuxiliary Outputs Continuous Operating DeviceModels Compatible ProductsAdditional Resources Associated EquipmentInstallation Mounting96 x 16 System Default Camera Numbers Video SourcesCable Type Maximum Distance Main unit Cameras Expansion unit CamerasConnecting Looping Video Sources Control Lines 96 x 16 System PTZ Control CapacityMonitors 96 x 16 System Monitor CapacityMain unit Monitor Expansion Unit Monitor Alarms 96 x 16 System Alarm CapacityMain unit Alarms Expansion Unit Alarms Connecting Devices Through the Communication Ports Input Type Wiring Pin-Outs Default DeviceCM9760-MDA, Ascii RS-485 Pin-Outs Ascii device CM9760-MDA, Satellite Rx+ Ground Tx+ RS-232 Pin-Outs RJ-45Port RS-485, 19200 baud, no parity, 8 data bits, 1 stop bitCM6800E Communication Port Connections and Options KBD100, KBD200A, and KBD300A Direct-Powered Keyboards KBD100, KBD200A, and KBD300A Series KeyboardsKeyboard Address Switch Settings Table E. Switch Settings-KBD200A/300A Keyboards OnlyKeyboard Switch OFFKBD100, KBD200A, and KBD300A Remote Keyboards Remote KeyboardsDevices KBD960, ALM2064, REL2064 Devices AddressingKBD960/KBR960 REL2064 ALM2064 Connecting a Single KBD960/KBR960 Keyboard Connecting a KBD960/KBR960 to the CM6800EConnecting a Single ALM2064 Alarm Interface Unit To connect a single ALM2064 Alarm Interface UnitConnecting a Single REL2064 Relay Interface Unit To connect a single REL2064 Relay Interface UnitMultiple M Devices Multiple M Devices Local ConnectionConnecting Multiple M Devices Remote Connection Multiple M Devices Remote ConnectionConnecting a PC PC Connection to RJ-45 PortConnecting Genex Multiplexers Connecting Genex MultiplexersConnecting Relay Contacts AUX 1 Local Auxiliaries96 x 16 System Auxiliary Capacity Main unit AUX Expansion Unit AUXConnecting the Open Collector Output F3 TTL Wiring the F3 TTL OutputConnecting a 96 X 16 System CM6800E-48X8 Main UnitPOWER-UP the System System START-UPInitialize Keyboards Configure the System Port Default SettingsCommunication Ports COM96 X 16 System Settings KBD960/KBR960 KeyboardGenex Multiplexer Control MUXMonitor Color Adjustment Program PresetsAdditional Programming Programming the CM6800E CM6800E Programming Mode Exit Programming ModeSelect Language Entries in Programming Mode FunctionKeyboard Navigate to the Help field Press F1 Navigate to the Next or Previous field Press F1Access Keyboard to MonitorCamera to Keyboard Camera to MonitorAlarm Programming Program Alarm GroupsProgram AN Internal or External Alarm Contact AUX field, select an auxiliary to be activated ACK TypeType PriorityProgram a Video Loss Alarm Program Video Loss AlarmsAssign a Logical Alarm Number Optional Assign a Logical Alarm NumberAlarm-based Operation Mode field for each auxiliary, select either LAT or MOMAuxiliary Outputs Latching or Momentary OperationCamera Programming Program Logical NumbersIf necessary, first program logical camera number Program Cameras Program Vertical Drive Option Optional Select CharacterEvent Timers Macros Macro Status View ScreenMonitor Display MonitorCamera Title Type Display ValuesMonitor Status Display Values ALM Status Display ValuesTime DatePassword Use the Set Password screen to change the system passwordPorts SERIAL/COM Ports Serial Port Input on CM6800E rear panelAction Ascii text Priority PortOptions Level 1 = highest priority Level 8 = lowest priority96 X 16 System Settings Change the System SettingSequences SequenceAUX and ## Turn global auxiliary onTurn global auxiliary off Turn camera auxiliary onPATTERNS, PRESETS, and Zones Time and DateOptions DD/MMM/YY MMM/DD/YY YY/MMM/DD DD/MM/YY YY/MM/DD Switch Monitors OperationOverview Operating the CM6800EControl Receivers Operate Sequences To move through the sequence one camera at a timeRUN a Macro Select Macro to start the macroSelect To start the macro Acknowledge AN Alarm Call a PresetCreate and RUN a Pattern Patterns are not available with the KBD100 keyboardOperate AUXILIARIES/RELAYS Operate a Local AuxiliaryOperate an External Auxiliary Operate an Auxiliary in a ReceiverControl Genex Multiplexer and Genex Multiplexer Displays Operate Scanning FunctionsDetect Video Loss Define ZonesCM6800E DIP Switches CM6800E DIP Switch Default SettingSwitch AppendixAlarm Group Display Options Monitor Alarm AlarmsBlock Build Chronological Pair D and QMonitor Alarm Alarms Next Display Cycle Reverse Chronological Pair M and LSalvo Group Macro Commands Description Specify FieldsAuxiliary Notes Pipo QuadNano HEXInstall the CM6800E AS a Satellite Device Page Configure the CM6800E AS a Satellite Device Satellite Monitor AccessSatellite Port Settings Change the Port SettingSatellite Alarms Optional Enable Alarm ContactsConfigure CM9700-MGR System Manager Settings Add a Satellite Device in the CM9700-MGRConfigure CM9760-MGR System Manager Settings Program the Comms File Click the Comms tab. The Comms page appearsProgram the Cameras File Click the Cameras tab. The Cameras page appearsProgram the Link Cameras File Click the Link Cameras tab. The Link Cameras page appearsProgram the Alarms File Optional Click the Alarms tab. The Alarms page appearsClick OK to close the Alarm Camera Switches dialog box How to Display the CM6800E Programming Main Menu How to Exit Programming ModeHow to Select a Numerical Value in an Option Field Press 89 PresetLogical Number Assignment Table for Link Cameras Link Camera NameLink Camera page Phy Num column Ascii Operating Commands Functional Procedure Commands Result3Ma16#a Desired Action Command Result Uppercase characters48~Jva Trigger an alarm #Ea Clear an alarm #IaAcknowledge an alarm #Ka Panel An alarm is triggered #Ea Logical Alarm Number in the Alarm Programming sectionTroubleshooting Gaining Initial ControlWait AT Least Five Seconds Software Reset Dip Switch Cover PlateSolutions to Common Problems Problem RemedyKBD960/KBR960 ICON/BUTTON Legend Icon/Button LegendUpgrade the CM6800 Switcher Software Upgrade the CM6800 Switcher SoftwareGlossary Term DefinitionAscii Ntsc PALPTZ All four wires Star configurationRS-422 Recommended distance is 4,000 feet 1,219 mSpecifications Regulatory Notices 48 x 8 System96 x 16 System Product Warranty and Return Information C1528M-F 6/05 105 ISO9001