Pelco CM6800E-48X8 manual Macro Commands, Description Specify Fields, Auxiliary Notes

Page 76

MACRO COMMANDS

Table H provides a description of each macro command and the additional fields required for each command. Refer to the Macro section for instructions on programming macros.

Table H. Macro Commands

Command

Description

Specify

Field(s)

 

 

 

 

GON

Activate an auxiliary.

Auxiliary

Command #

 

 

 

 

GOFF

Turn off an auxiliary.

Auxiliary

Command #

 

 

 

 

Auxiliary Notes:

 

 

• “Global” includes both internal and external auxiliaries.

 

 

• Auxiliaries on the rear panel of the CM6800E Matrix Switcher are activated by global auxiliary numbers 1, 2 and 3.

 

 

 

 

 

CON

Activate a camera auxiliary.

Camera auxiliary

Command #

 

 

 

 

 

 

Camera

Camera

 

 

 

 

 

 

Monitor

Monitor

 

 

 

 

COFF

Turn off a camera auxiliary.

Camera auxiliary

Command #

 

 

 

 

 

 

Camera

Camera

 

 

 

 

 

 

Monitor

Monitor

 

 

 

 

SEQ

Start a sequence. A sequence runs continuously until a system operator selects

Sequence

Command #

 

a different camera, or an event timer starts another sequence or macro.

 

 

 

Monitor

Monitor

 

 

 

 

 

 

SWT

Switch a camera to a monitor.

Camera

Camera

 

 

 

 

 

 

Monitor

Monitor

 

 

 

 

COPY

Copy a camera view to a monitor.

Monitor to copy from

Command #

 

 

 

 

 

 

Monitor to copy to

Monitor

 

 

 

 

GO TO

Go to step number specified.

Step

Command #

 

 

 

 

LOOP

Loop a macro.

0 = loop continuously

Command #

 

 

1-999 = loop the specified

 

 

 

number of times

 

 

 

 

 

?AUX

Check a local auxiliary; if the auxiliary is active, the next step is executed; if

Local auxiliary

Command #

 

the auxiliary is not active, the next step is skipped.

 

 

 

 

 

 

?ALM

Check an internal alarm; if the alarm is active, the next step is executed; if

Alarm

Command #

 

not, the next step is skipped.

 

 

 

 

 

 

?SW

Check whether a camera is displayed on a monitor; if it is, the next step is

Camera

Camera

 

executed; if not, the next step is skipped.

 

 

 

Monitor

Monitor

 

 

 

 

 

 

STPM

Stop a macro.

Macro

Command #

 

 

 

 

END

Exit the macro; no further steps are executed. Any macro or sequence started

None

None

 

by this macro will continue to run.

 

 

 

 

 

 

DON

Displays on-screen text on the specified monitor.

Monitor

Monitor

 

 

 

 

DOFF

Removes on-screen text from the specified monitor.

Monitor

Monitor

 

 

 

 

MSWT

Switch a camera connected through the multiplexer.

Camera to switch

Command #

 

 

Multiplexer input

Camera

 

 

 

 

 

 

Monitor

Monitor

 

 

 

 

PIPB

Display multiplexer picture-in-picture view with the

Background camera

Command #

 

designated camera in the background.

 

 

 

Multiplexer input

Camera

 

 

 

 

 

 

 

 

Monitor

Monitor

 

 

 

 

PIPF

Display multiplexer picture-in-picture view with the

Foreground camera

Command #

 

designated camera in the foreground.

 

 

 

Multiplexer input

Camera

 

 

 

 

 

 

 

 

Monitor

Monitor

For multiplexer functions, the camera number is the number of the video input on the multiplexer. The multiplexer input number is the number of the video input on the rear panel of the CM6800E.

(Continued on next page)

76

C1528M-F (6/05)

Image 76
Contents CM6800E-48X8 Contents Control Genex Multiplexer and Genex Multiplexer Displays List of Illustrations List of Tables C1528M-F 6/05 Important Safeguards and Warnings For Qualified Service Personnel onlyDescription Sample CM6800E-48X8 SystemSample CM6800E 96 x 16 System Sequences, Macros, Presets, Patterns, and Zones System Access and PriorityProgramming KeyboardsAlarm Inputs Power, Mounting MethodsAuxiliary Outputs Continuous Operating DeviceModels Compatible ProductsAdditional Resources Associated EquipmentInstallation Mounting96 x 16 System Default Camera Numbers Video SourcesCable Type Maximum Distance Main unit Cameras Expansion unit CamerasConnecting Looping Video Sources Control Lines 96 x 16 System PTZ Control Capacity96 x 16 System Monitor Capacity MonitorsMain unit Monitor Expansion Unit Monitor 96 x 16 System Alarm Capacity AlarmsMain unit Alarms Expansion Unit Alarms Input Type Wiring Pin-Outs Default Device Connecting Devices Through the Communication PortsCM9760-MDA, Ascii RS-485 Pin-Outs Ascii device CM9760-MDA, Satellite Rx+ Ground Tx+ RS-232 Pin-Outs RJ-45Port RS-485, 19200 baud, no parity, 8 data bits, 1 stop bitCM6800E Communication Port Connections and Options KBD100, KBD200A, and KBD300A Direct-Powered Keyboards KBD100, KBD200A, and KBD300A Series KeyboardsKeyboard Address Switch Settings Table E. Switch Settings-KBD200A/300A Keyboards OnlyKeyboard Switch OFFKBD100, KBD200A, and KBD300A Remote Keyboards Remote KeyboardsDevices Addressing Devices KBD960, ALM2064, REL2064KBD960/KBR960 REL2064 ALM2064 Connecting a Single KBD960/KBR960 Keyboard Connecting a KBD960/KBR960 to the CM6800EConnecting a Single ALM2064 Alarm Interface Unit To connect a single ALM2064 Alarm Interface UnitConnecting a Single REL2064 Relay Interface Unit To connect a single REL2064 Relay Interface UnitMultiple M Devices Multiple M Devices Local ConnectionConnecting Multiple M Devices Remote Connection Multiple M Devices Remote ConnectionConnecting a PC PC Connection to RJ-45 PortConnecting Genex Multiplexers Connecting Genex MultiplexersConnecting Relay Contacts AUX 1 Local Auxiliaries96 x 16 System Auxiliary Capacity Main unit AUX Expansion Unit AUXConnecting the Open Collector Output F3 TTL Wiring the F3 TTL OutputConnecting a 96 X 16 System CM6800E-48X8 Main UnitSystem START-UP POWER-UP the SystemInitialize Keyboards Configure the System Port Default SettingsCommunication Ports COM96 X 16 System Settings KBD960/KBR960 KeyboardGenex Multiplexer Control MUXProgram Presets Monitor Color AdjustmentAdditional Programming Programming the CM6800E Exit Programming Mode CM6800E Programming ModeSelect Language Function Entries in Programming ModeKeyboard Navigate to the Help field Press F1 Navigate to the Next or Previous field Press F1Access Keyboard to MonitorCamera to Keyboard Camera to MonitorAlarm Programming Program Alarm GroupsProgram AN Internal or External Alarm Contact AUX field, select an auxiliary to be activated ACK TypeType PriorityProgram a Video Loss Alarm Program Video Loss AlarmsAssign a Logical Alarm Number Optional Assign a Logical Alarm NumberAlarm-based Operation Mode field for each auxiliary, select either LAT or MOMAuxiliary Outputs Latching or Momentary OperationProgram Logical Numbers Camera ProgrammingIf necessary, first program logical camera number Program Cameras Program Vertical Drive Option Optional Select CharacterEvent Timers Macros Macro Status View ScreenMonitor Display MonitorCamera Title Type Display ValuesMonitor Status Display Values ALM Status Display ValuesTime DatePassword Use the Set Password screen to change the system passwordSerial Port Input on CM6800E rear panel Ports SERIAL/COM PortsAction Ascii text Priority PortOptions Level 1 = highest priority Level 8 = lowest priority96 X 16 System Settings Change the System SettingSequences SequenceAUX and ## Turn global auxiliary onTurn global auxiliary off Turn camera auxiliary onTime and Date PATTERNS, PRESETS, and ZonesOptions DD/MMM/YY MMM/DD/YY YY/MMM/DD DD/MM/YY YY/MM/DD Switch Monitors OperationOverview Operating the CM6800EControl Receivers Operate Sequences To move through the sequence one camera at a timeSelect Macro to start the macro RUN a MacroSelect To start the macro Acknowledge AN Alarm Call a PresetCreate and RUN a Pattern Patterns are not available with the KBD100 keyboardOperate AUXILIARIES/RELAYS Operate a Local AuxiliaryOperate an External Auxiliary Operate an Auxiliary in a ReceiverControl Genex Multiplexer and Genex Multiplexer Displays Operate Scanning FunctionsDetect Video Loss Define ZonesCM6800E DIP Switches CM6800E DIP Switch Default SettingSwitch AppendixAlarm Group Display Options Monitor Alarm AlarmsBlock Build Chronological Pair D and QReverse Chronological Pair M and L Monitor Alarm Alarms Next Display CycleSalvo Group Description Specify Fields Macro CommandsAuxiliary Notes Pipo QuadNano HEXInstall the CM6800E AS a Satellite Device Page Configure the CM6800E AS a Satellite Device Satellite Monitor AccessSatellite Port Settings Change the Port SettingSatellite Alarms Optional Enable Alarm ContactsConfigure CM9700-MGR System Manager Settings Add a Satellite Device in the CM9700-MGRConfigure CM9760-MGR System Manager Settings Program the Comms File Click the Comms tab. The Comms page appearsProgram the Cameras File Click the Cameras tab. The Cameras page appearsProgram the Link Cameras File Click the Link Cameras tab. The Link Cameras page appearsClick the Alarms tab. The Alarms page appears Program the Alarms File OptionalClick OK to close the Alarm Camera Switches dialog box How to Display the CM6800E Programming Main Menu How to Exit Programming ModeHow to Select a Numerical Value in an Option Field Press 89 PresetLink Camera Name Logical Number Assignment Table for Link CamerasLink Camera page Phy Num column Functional Procedure Commands Result Ascii Operating Commands3Ma16#a Desired Action Command Result Uppercase characters48~Jva Trigger an alarm #Ea Clear an alarm #IaAcknowledge an alarm #Ka Panel An alarm is triggered #Ea Logical Alarm Number in the Alarm Programming sectionGaining Initial Control TroubleshootingWait AT Least Five Seconds Software Reset Dip Switch Cover PlateSolutions to Common Problems Problem RemedyKBD960/KBR960 ICON/BUTTON Legend Icon/Button LegendUpgrade the CM6800 Switcher Software Upgrade the CM6800 Switcher SoftwareTerm Definition GlossaryAscii PAL NtscPTZ All four wires Star configurationRS-422 Recommended distance is 4,000 feet 1,219 mSpecifications 48 x 8 System Regulatory Notices96 x 16 System Product Warranty and Return Information C1528M-F 6/05 105 ISO9001