Pelco FR82041 manual Connections, 10BASE-T/100BASE-TX connections

Page 15

CONNECTIONS

Connections to the FT82041/FR82041 module are made on the rear panel of the unit (refer to Figure 6).

POWER/ALARM CONNECTION

FOR RACK-MOUNTED MODULE

POWER CONNECTION

FOR STAND-ALONE MODULE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

FIBER OPTIC CABLE

Figure 6. FT82041/FR82041 Module Connections

As illustrated in Figure 6, FT82041/FR82041 connections consist of the following:

Power connection

NOTES:

A 12 VDC or 24 VAC power supply can be used to power the module when used as a stand-alone unit. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 0.50 A (minimum output).

In extreme temperature conditions, it is recommended that an industrial-rated outdoor power supply such as the Pelco WCS1-4 power supply be used.

10BASE-T/100BASE-TX connections

NOTES:

Use Cat5e or a higher category of cable to connect to a 10BASE-T/100BASE-TX port. Cable length must not exceed 328 feet (100 meters).

The 10BASE-T/100BASE-TX ports are auto MDI/MDI-X ports; therefore, either a straight-through or crossover cable can be used. The ports automatically detect the cable type that is used. Refer to Appendix. RJ-45 Connector Pinouts on page 26 for pinout information.

C2623M (2/07)

15

Image 15
Contents FT82041/FR82041 Unmanaged Ethernet Switch Page Contents List of IllustrationsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewModels Multimode ModelsSingle-Mode Models*† 100BASE-FX Status LED Power LED Pelco badgeFront Panel RK5000PS-5U rack mount chassisRear Panel 10BASE-T/100BASE-TX Ports 1-4 RJ-45 connectorsPackage Contents InstallationAutonegotiation is enabled by default Flow control default setting10BASE-T/100BASE-TX Modes of Operation Mounting the FT82041/FR82041 Module Into a Rack MountingMounting the FT82041/FR82041 Module Using the Wall Clip 10BASE-T/100BASE-TX connections ConnectionsFiber connection Troubleshooting Meaning Possible Cause Corrective Action Optic Fault LED 11 for information Table C. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting Amber 10BASE-T link is If 10BASE-T operation is EstablishedMeaning Possible Cause Corrective Action Flashing amber Port is set to Normal or excessive Refer to SettingIf half-duplex mode is Amber Port is set to100BASE-TX half Duplex mode LinkGreen Port is set to If 100BASE-TX full-duplex Flashing green Port is set toTable C. Troubleshooting with Rear-Panel Indicators Link/activity and speed, duplex/collision and speed SpecificationsMultimode 62.5/125 μm Model Number Wavelength Optical Maximum Transmit/ReceiveReceiver EndIllustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001