Pelco FR82041 manual Amber Port is set to, Flashing amber Port is set to Normal or excessive

Page 21

Table C. Troubleshooting with Rear-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

 

Corrective Action

 

 

 

 

RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision)

 

 

 

 

Amber

Port is set to

If 10BASE-T full-duplex opera-

 

10BASE-T full-

 

tion is desired, no action is

 

duplex mode.

 

required. If 10BASE-T full-

 

 

 

duplex operation is not

 

 

 

desired, refer to Setting

 

 

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation on

 

 

 

page 11 for information.

 

 

 

 

Flashing amber

Port is set to

Normal or excessive

If a normal collision occurs, no

 

10BASE-T half-

collisions occur on a

action is required.

 

duplex mode and

half-duplex link.*

If a problem with the network

 

network collision

 

exists due to excessive colli-

 

has occurred.*

 

sions, do any of the following

 

 

 

as appropriate:

 

 

 

If half-duplex mode is not

 

 

 

required, set the TX Mode

 

 

 

switch to full-duplex mode

 

 

 

by means of autonegotia-

 

 

 

tion or by forcing the mode

 

 

 

(refer to Setting

 

 

 

10BASE-T/100BASE-TX

 

 

 

Port Modes of Operation

 

 

 

on page 11 for

 

 

 

information).

 

 

 

If half-duplex mode is

 

 

 

required, do any of the

 

 

 

following as applicable:

 

 

 

Replace network cable

 

 

 

 

if it is defective or if it

 

 

 

 

is not the proper cable

 

 

 

 

type. Use Cat5e or

 

 

 

 

higher cable.

 

 

 

Ensure that cable is the

 

 

 

 

proper length. Cable

 

 

 

 

length must not exceed

 

 

 

 

328 feet (100 meters).

 

 

 

Replace the network

 

 

 

 

interface card (NIC) if it

 

 

 

 

is defective or if it is

 

 

 

 

incompatible.

 

 

 

Segment the network.

 

 

 

 

(Continued on next page)

C2623M (2/07)

21

Image 21
Contents FT82041/FR82041 Unmanaged Ethernet Switch Page Contents List of IllustrationsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewModels Multimode ModelsSingle-Mode Models*† Front Panel Power LED Pelco badgeRK5000PS-5U rack mount chassis 100BASE-FX Status LEDRear Panel 10BASE-T/100BASE-TX Ports 1-4 RJ-45 connectorsPackage Contents InstallationAutonegotiation is enabled by default Flow control default setting10BASE-T/100BASE-TX Modes of Operation Mounting the FT82041/FR82041 Module Into a Rack MountingMounting the FT82041/FR82041 Module Using the Wall Clip 10BASE-T/100BASE-TX connections ConnectionsFiber connection Troubleshooting Meaning Possible Cause Corrective Action Optic Fault LED Desired, refer to Setting Table C. Troubleshooting with Rear-Panel IndicatorsAmber 10BASE-T link is If 10BASE-T operation is Established 11 for informationMeaning Possible Cause Corrective Action If half-duplex mode is Refer to SettingAmber Port is set to Flashing amber Port is set to Normal or excessiveGreen Port is set to If 100BASE-TX full-duplex Duplex mode LinkFlashing green Port is set to 100BASE-TX halfTable C. Troubleshooting with Rear-Panel Indicators Link/activity and speed, duplex/collision and speed SpecificationsReceiver Model Number Wavelength Optical Maximum Transmit/ReceiveEnd Multimode 62.5/125 μmIllustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001