Pelco FR82041 manual Troubleshooting

Page 17

Troubleshooting

LED indicators on the front and rear panels of the FT82041/FR82041 module allow you to monitor operational status:

LED indicators on the front panel allow you to monitor operating power, 100BASE-FX port status, and optic signal/laser status. Refer to Table B for information about the front-panel indicators and associated troubleshooting guidelines.

LED indicators on the rear panel allow you to monitor RJ-45 10BASE-T/100BASE-TX port status. Refer to Table C for information about the rear-panel indicators and associated troubleshooting guidelines.

Table B. Troubleshooting with Front-Panel Indicators

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

Power LED (Pelco badge)

Blue

Not lit

Power is being

No action required.

applied to the

 

 

module.

 

 

Power is not being

Power connection is faulty.

Check power connection.

applied to the

 

If module is rack mounted,

module.

 

reseat module or power

 

 

supply as necessary.

 

 

 

 

Power supply has failed.

Replace power supply.

 

 

 

 

Loss of power occurs due to

Check circuit breakers, fuses,

 

tripped circuit breakers,

or electrical service as

 

blown fuses, or faulty elec-

necessary.

 

trical service.

 

 

 

 

 

100BASE-FX Status LED (

)

 

 

 

 

 

 

Green

A fiber link is estab-

 

No action is required.

 

lished.

 

 

 

 

 

 

 

 

Flashing green

Data activity is

 

No action is required.

 

occurring on the fiber

 

 

 

 

link.

 

 

 

 

 

 

 

Red

Far end fault indica-

Defective fiber transmit port

Replace local module.

 

tion (FEFI).

on local module

 

 

 

The optical signal

 

 

 

 

Laser fault on local module

Refer to the Optic Fault LED

 

transmitted from this

 

(Optic Fault LED on local

section in this table.

 

port is not detected

 

module flashes red).

 

 

 

by the remote link

 

 

 

 

 

 

 

Defective fiber receive port

Replace remote module.

 

partner.

 

on remote module

 

 

 

 

 

 

 

 

 

 

 

NOTE: The Optic Fault LED on the remote module is red. Refer to the Optic Fault

 

LED section in this table for additional information.

 

 

 

 

 

 

 

 

 

 

(Continued on next page)

C2623M (2/07)

17

Image 17
Contents FT82041/FR82041 Unmanaged Ethernet Switch Page List of Tables ContentsList of Illustrations Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewSingle-Mode Models*† ModelsMultimode Models Front Panel Power LED Pelco badgeRK5000PS-5U rack mount chassis 100BASE-FX Status LEDRear Panel 10BASE-T/100BASE-TX Ports 1-4 RJ-45 connectorsPackage Contents Installation10BASE-T/100BASE-TX Modes of Operation Autonegotiation is enabled by defaultFlow control default setting Mounting the FT82041/FR82041 Module Into a Rack MountingMounting the FT82041/FR82041 Module Using the Wall Clip 10BASE-T/100BASE-TX connections ConnectionsFiber connection Troubleshooting Meaning Possible Cause Corrective Action Optic Fault LED Desired, refer to Setting Table C. Troubleshooting with Rear-Panel IndicatorsAmber 10BASE-T link is If 10BASE-T operation is Established 11 for informationMeaning Possible Cause Corrective Action If half-duplex mode is Refer to SettingAmber Port is set to Flashing amber Port is set to Normal or excessiveGreen Port is set to If 100BASE-TX full-duplex Duplex mode LinkFlashing green Port is set to 100BASE-TX halfTable C. Troubleshooting with Rear-Panel Indicators Link/activity and speed, duplex/collision and speed SpecificationsReceiver Model Number Wavelength Optical Maximum Transmit/ReceiveEnd Multimode 62.5/125 μmIllustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001