Pelco manual FX82052, -2 Models Multimode Models, Single-Mode Models†

Page 10

MODELS

The FX82052 module consists of the following series of models:

FX82052, -2 MODELS*

Multimode Models

FX82052MSTR-2 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two multimode ST fiber ports, one fiber per port (total of two fibers)

FX82052MSCR-2 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two multimode SC fiber ports, one fiber per port (total of two fibers)

Single-Mode Models

FX82052SSTR-2 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two single- mode ST fiber ports, one fiber per port (total of two fibers)

FX82052SSCR-2 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two single- mode SC fiber ports, one fiber per port (total of two fibers)

FX82052, -4 MODELS*

Multimode Models

FX82052MSTR-4 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two multimode ST fiber ports, two fibers per port (total of four fibers)

FX82052MSCR-4 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two multimode SC fiber ports, two fibers per port (total of four fibers)

Single-Mode Models

FX82052SSTR-4 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two single- mode ST fiber ports, two fibers per port (total of four fibers)

FX82052SSCR-4 Unmanaged Ethernet switch, five 10BASE-T/100BASE-TX ports, two single- mode SC fiber ports, two fibers per port (total of four fibers)

*For conformal coated models, replace the first letter F in the model number with the letter C. The conformal coated version of FX82052MSTR-2, for example, is CX82052MSTR-2.

Single-mode FC connectors are available upon request. Contact the factory for additional information.

OPTIONAL ACCESSORIES

The following optional accessories are available:

WM5002-3U

Wall mount base kit for double-width module

WM5002-3UEXP

Wall mount expansion kit for double-width module

RK5000-3U

19-inch rack mount chassis for 14 slots (no power), 3 RUs

RK5000PS-3U

19-inch rack mount chassis for 12 slots with power, 3 RUs

EPS5000-120

External rack power supply, 1 RU, dual 120 W power outputs

RK5001B-3U

Blank filler panel, single width

RK5002B-3U

Blank filler panel, double width

RK5002-1UEXP

Adapter kit that allows a 3 RU double-width fiber module to be used in

 

RK5000PS-5U rack mount chassis

10

C2607M (2/07)

Image 10
Contents Ethernet Switch Contents List of IllustrationsTX Mode Switch Settings FX Mode Switch Settings List of TablesImportant Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionPOINT-TO-POINT Application with Fiber Redundancy C2607M 2/07 Single-Mode Models† ModelsFX82052, -2 Models Multimode Models FX82052, -4 Models Multimode ModelsFront Panel Power LED Pelco badge100BASE-FX Status LED Per fiber port a and B 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectors Rear Panel10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectors FX82052 Rear PANEL, -4 ModelsInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultFlow control default setting Setting Fiber Failover ModeTable A. TX Mode Switch Settings 10BASE-T/100BASE-TX Modes of OperationDefault setting Table B. FX Mode Switch SettingsMode of Operation Secondary fiber linkMounting Mounting the FX82052 Module Into a RackMounting the FX82052 Module Using the Wall Clip FX82052 Connections, -4 Models SC Fiber Connectors Shown Connections10BASE-T/100BASE-TX connections Fiber connectionsFiber Link FX Mode Position Fiber Ports a and B Are Independent FX Mode Position FX Mode Position Fiber Ports a and B Are Independent Module Reseat module or power Supply as necessary TroubleshootingCheck power connection Replace power supplyMeaning Replace local module Indication Fefi On local module Optical signalOptic Fault LED on local Section in this table By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Amber Table D. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting If 10BASE-T operation isMeaning Possible Cause Corrective Action Refer to Setting Duplex modeDuplex mode Duplex link If half-duplex mode isFull-duplex operation is not Mode refer to SettingGreen Port is set to If 100BASE-TX full-duplex Flashing green Port is set to Normal or excessiveTable D. Troubleshooting with Rear-Panel Indicators Optic Fault optic signal/laser status per fiber port SpecificationsLink/activity and speed, duplex/collision and speed Single-Mode 9/125 μm FX82052, -2 Models Wavelength Optical MaximumMultimode 62.5/125 μm FX82052SSTR-2Fibers Appendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001