Pelco FX82052 manual FX Mode Position Fiber Ports a and B Are Independent

Page 25

FX MODE POSITION 0:

FIBER PORTS A AND B

ARE INDEPENDENT.

FX MODE POSITION 0:

FIBER PORTS A AND B

ARE INDEPENDENT.

FX MODE POSITION 0:

FIBER PORTS A AND B

ARE INDEPENDENT.

Figure 14. Fiber Port Connections in Sample Drop-and-Repeat Application, -4 Models

C2607M (2/07)

25

Image 25
Contents Ethernet Switch List of Illustrations ContentsList of Tables TX Mode Switch Settings FX Mode Switch SettingsImportant Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewPOINT-TO-POINT Application with Fiber Redundancy C2607M 2/07 FX82052, -2 Models Multimode Models ModelsSingle-Mode Models† FX82052, -4 Models Multimode ModelsFront Panel Power LED Pelco badge100BASE-FX Status LED Per fiber port a and B Rear Panel 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectorsFX82052 Rear PANEL, -4 Models 10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectorsPackage Contents InstallationFlow control is disabled by default Autonegotiation is enabled by defaultTable A. TX Mode Switch Settings Setting Fiber Failover ModeFlow control default setting 10BASE-T/100BASE-TX Modes of OperationMode of Operation Table B. FX Mode Switch SettingsDefault setting Secondary fiber linkMounting the FX82052 Module Into a Rack MountingMounting the FX82052 Module Using the Wall Clip Connections FX82052 Connections, -4 Models SC Fiber Connectors ShownFiber connections 10BASE-T/100BASE-TX connectionsFiber Link FX Mode Position Fiber Ports a and B Are Independent FX Mode Position FX Mode Position Fiber Ports a and B Are Independent Check power connection TroubleshootingModule Reseat module or power Supply as necessary Replace power supplyMeaning Optic Fault LED on local Section in this table Indication Fefi On local module Optical signalReplace local module By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Desired, refer to Setting Table D. Troubleshooting with Rear-Panel IndicatorsAmber If 10BASE-T operation isMeaning Possible Cause Corrective Action Duplex mode Duplex link Duplex modeRefer to Setting If half-duplex mode isGreen Port is set to If 100BASE-TX full-duplex Mode refer to SettingFull-duplex operation is not Flashing green Port is set to Normal or excessiveTable D. Troubleshooting with Rear-Panel Indicators Optic Fault optic signal/laser status per fiber port SpecificationsLink/activity and speed, duplex/collision and speed Multimode 62.5/125 μm FX82052, -2 Models Wavelength Optical MaximumSingle-Mode 9/125 μm FX82052SSTR-2Fibers Illustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001