Pelco FX82052 Front Panel, 100BASE-FX Status LED Per fiber port a and B, Power LED Pelco badge

Page 11

FRONT PANEL

Figure 3 illustrates the front panel of the FX82052 module.

Figure 3. Front Panel of FX82052 Module

ìReset Button: Restarts the unit

îFiber Failover: Fiber Redundancy Mode LED

ï100BASE-FX Status LED: Per fiber port A and B

ñOptic Fault LED: Optical signal status/laser status indicator per fiber port A and B

óPower LED: Pelco badge

For detailed information about the front-panel LEDs, refer to Troubleshooting on page 26.

C2607M (2/07)

11

Image 11
Contents Ethernet Switch List of Illustrations ContentsList of Tables TX Mode Switch Settings FX Mode Switch SettingsImportant Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewPOINT-TO-POINT Application with Fiber Redundancy C2607M 2/07 FX82052, -4 Models Multimode Models ModelsFX82052, -2 Models Multimode Models Single-Mode Models†100BASE-FX Status LED Per fiber port a and B Power LED Pelco badgeFront Panel Rear Panel 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectorsFX82052 Rear PANEL, -4 Models 10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectorsPackage Contents InstallationFlow control is disabled by default Autonegotiation is enabled by default10BASE-T/100BASE-TX Modes of Operation Setting Fiber Failover ModeTable A. TX Mode Switch Settings Flow control default settingSecondary fiber link Table B. FX Mode Switch SettingsMode of Operation Default settingMounting the FX82052 Module Into a Rack MountingMounting the FX82052 Module Using the Wall Clip Connections FX82052 Connections, -4 Models SC Fiber Connectors ShownFiber connections 10BASE-T/100BASE-TX connectionsFiber Link FX Mode Position Fiber Ports a and B Are Independent FX Mode Position FX Mode Position Fiber Ports a and B Are Independent Replace power supply TroubleshootingCheck power connection Module Reseat module or power Supply as necessaryMeaning By the remote link Indication Fefi On local module Optical signalOptic Fault LED on local Section in this table Replace local moduleMeaning Possible Cause Corrective Action Optic Fault LED If 10BASE-T operation is Table D. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting AmberMeaning Possible Cause Corrective Action If half-duplex mode is Duplex modeDuplex mode Duplex link Refer to SettingFlashing green Port is set to Normal or excessive Mode refer to SettingGreen Port is set to If 100BASE-TX full-duplex Full-duplex operation is notTable D. Troubleshooting with Rear-Panel Indicators Link/activity and speed, duplex/collision and speed SpecificationsOptic Fault optic signal/laser status per fiber port FX82052SSTR-2 FX82052, -2 Models Wavelength Optical MaximumMultimode 62.5/125 μm Single-Mode 9/125 μmFibers Illustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001