Pelco FX82052 manual Table D. Troubleshooting with Rear-Panel Indicators, Amber, for information

Page 30

Table D. Troubleshooting with Rear-Panel Indicators

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity)

 

 

 

 

Amber

A 10BASE-T link is

If 10BASE-T operation is

 

established.

 

desired, no action is required.

 

 

 

If 10BASE-T operation is not

 

 

 

desired, refer to Setting

 

 

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation on

 

 

 

page 14 for information.

 

 

 

 

Flashing amber

Data activity is

If 10BASE-T operation is

 

occurring on the

 

desired, no action is required.

 

10BASE-T link; data

 

If 10BASE-T operation is not

 

is being transmitted

 

desired, refer to Setting

 

or received.

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation on

 

 

 

page 14 for information.

 

 

 

 

Green

A 100BASE-TX link

If 100BASE-TX operation is

 

is established.

 

desired, no action is required.

 

 

 

If 100BASE-TX operation is

 

 

 

not desired, refer to Setting

 

 

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation on

 

 

 

page 14 for information.

 

 

 

 

Flashing green

Data activity is

If 100BASE-TX operation is

 

occurring on the

 

desired, no action is required.

 

100BASE-TX link;

 

If 100BASE-TX operation is

 

data is being trans-

 

not desired, refer to Setting

 

mitted or received.

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation on

 

 

 

page 14 for information.

 

 

 

 

 

 

 

(Continued on next page)

30

C2607M (2/07)

Image 30
Contents Ethernet Switch Contents List of IllustrationsTX Mode Switch Settings FX Mode Switch Settings List of TablesImportant Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionPOINT-TO-POINT Application with Fiber Redundancy C2607M 2/07 Single-Mode Models† ModelsFX82052, -2 Models Multimode Models FX82052, -4 Models Multimode ModelsPower LED Pelco badge Front Panel100BASE-FX Status LED Per fiber port a and B 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectors Rear Panel10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectors FX82052 Rear PANEL, -4 ModelsInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultFlow control default setting Setting Fiber Failover ModeTable A. TX Mode Switch Settings 10BASE-T/100BASE-TX Modes of OperationDefault setting Table B. FX Mode Switch SettingsMode of Operation Secondary fiber linkMounting Mounting the FX82052 Module Into a RackMounting the FX82052 Module Using the Wall Clip FX82052 Connections, -4 Models SC Fiber Connectors Shown Connections10BASE-T/100BASE-TX connections Fiber connectionsFiber Link FX Mode Position Fiber Ports a and B Are Independent FX Mode Position FX Mode Position Fiber Ports a and B Are Independent Module Reseat module or power Supply as necessary TroubleshootingCheck power connection Replace power supplyMeaning Replace local module Indication Fefi On local module Optical signalOptic Fault LED on local Section in this table By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Amber Table D. Troubleshooting with Rear-Panel IndicatorsDesired, refer to Setting If 10BASE-T operation isMeaning Possible Cause Corrective Action Refer to Setting Duplex modeDuplex mode Duplex link If half-duplex mode isFull-duplex operation is not Mode refer to SettingGreen Port is set to If 100BASE-TX full-duplex Flashing green Port is set to Normal or excessiveTable D. Troubleshooting with Rear-Panel Indicators Specifications Optic Fault optic signal/laser status per fiber portLink/activity and speed, duplex/collision and speed Single-Mode 9/125 μm FX82052, -2 Models Wavelength Optical MaximumMultimode 62.5/125 μm FX82052SSTR-2Fibers Appendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001