Pelco manual FX82052 Connections, -4 Models SC Fiber Connectors Shown

Page 20

CONNECTIONS

Connections to the FX82052 module are made on the rear panel of the module. Refer to Figure 9 and to Figure 10 for illustrations of connections to FX82052, -2 models and FX82052, -4 models, respectively.

POWER/ALARM

CONNECTION FOR

RACK-MOUNTED MODULE

POWER CONNECTION FOR

STAND-ALONE MODULE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

FIBER OPTIC CABLE TO PORT B (CONNECTS TO PORT A ON REMOTE MODULE)

FIBER OPTIC CABLE TO PORT A (CONNECTS TO PORT B ON REMOTE MODULE)

Figure 9. FX82052 Connections, -2 Models (SC Fiber Connectors Shown)

POWER/ALARM

CONNECTION FOR

RACK-MOUNTED MODULE

POWER CONNECTION FOR

STAND-ALONE MODULE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

10/100 NETWORK CABLE

FIBER OPTIC CABLES

FIBER OPTIC CABLES

Figure 10. FX82052 Connections, -4 Models (SC Fiber Connectors Shown)

20

C2607M (2/07)

Image 20
Contents Ethernet Switch Contents List of IllustrationsTX Mode Switch Settings FX Mode Switch Settings List of TablesImportant Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionPOINT-TO-POINT Application with Fiber Redundancy C2607M 2/07 Models FX82052, -2 Models Multimode ModelsSingle-Mode Models† FX82052, -4 Models Multimode Models100BASE-FX Status LED Per fiber port a and B Power LED Pelco badgeFront Panel 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectors Rear Panel10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectors FX82052 Rear PANEL, -4 ModelsInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultSetting Fiber Failover Mode Table A. TX Mode Switch SettingsFlow control default setting 10BASE-T/100BASE-TX Modes of OperationTable B. FX Mode Switch Settings Mode of OperationDefault setting Secondary fiber linkMounting Mounting the FX82052 Module Into a RackMounting the FX82052 Module Using the Wall Clip FX82052 Connections, -4 Models SC Fiber Connectors Shown Connections10BASE-T/100BASE-TX connections Fiber connectionsFiber Link FX Mode Position Fiber Ports a and B Are Independent FX Mode Position FX Mode Position Fiber Ports a and B Are Independent Troubleshooting Check power connectionModule Reseat module or power Supply as necessary Replace power supplyMeaning Indication Fefi On local module Optical signal Optic Fault LED on local Section in this tableReplace local module By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Table D. Troubleshooting with Rear-Panel Indicators Desired, refer to SettingAmber If 10BASE-T operation isMeaning Possible Cause Corrective Action Duplex mode Duplex mode Duplex linkRefer to Setting If half-duplex mode isMode refer to Setting Green Port is set to If 100BASE-TX full-duplexFull-duplex operation is not Flashing green Port is set to Normal or excessiveTable D. Troubleshooting with Rear-Panel Indicators Link/activity and speed, duplex/collision and speed SpecificationsOptic Fault optic signal/laser status per fiber port FX82052, -2 Models Wavelength Optical Maximum Multimode 62.5/125 μmSingle-Mode 9/125 μm FX82052SSTR-2Fibers Appendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001