Pelco FX82052 Table B. FX Mode Switch Settings, Mode of Operation, Default setting, Not used

Page 17

TX Mode

0. Auto Neg / Dis FC

1. 100 FD / Dis FC

2. 100 HD / Dis FC

3. 10 FD / Dis FC

4. 10 HD / Dis FC

5. Auto Neg / En FC

6. 100 FD / En FC

7. 100 HD / En FC

8. 10 FD / En FC

9. 10 HD / En FC

FX Mode

0. Independent A & B

1. Auto Failover

A is Primary

2. Auto Failover

B is Primary

3-9 NOT USED

 

FX MODE SWITCH

 

Figure 7. FX Mode Switch

 

Table B. FX Mode Switch Settings

 

 

FX Mode

 

Switch Position

Mode of Operation

 

 

0

Independent A & B: Sets fiber ports A and B in nonredundant mode

 

(default setting).

 

 

1

Auto Failover, A is Primary: Sets fiber ports A and B in redundant mode.

 

Port A connects to the primary fiber link, and Port B connects to the

 

secondary fiber link.

 

 

2

Auto Failover, B is Primary: Sets fiber ports A and B in redundant mode.

 

Port B connects to the primary fiber link, and Port A connects to the

 

secondary fiber link.

 

 

3-9

Not used

 

 

C2607M (2/07)

17

Image 17
Contents Ethernet Switch List of Illustrations ContentsList of Tables TX Mode Switch Settings FX Mode Switch SettingsImportant Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewPOINT-TO-POINT Application with Fiber Redundancy C2607M 2/07 FX82052, -2 Models Multimode Models ModelsSingle-Mode Models† FX82052, -4 Models Multimode Models100BASE-FX Status LED Per fiber port a and B Power LED Pelco badgeFront Panel Rear Panel 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectorsFX82052 Rear PANEL, -4 Models 10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectorsPackage Contents InstallationFlow control is disabled by default Autonegotiation is enabled by defaultTable A. TX Mode Switch Settings Setting Fiber Failover ModeFlow control default setting 10BASE-T/100BASE-TX Modes of OperationMode of Operation Table B. FX Mode Switch SettingsDefault setting Secondary fiber linkMounting the FX82052 Module Into a Rack MountingMounting the FX82052 Module Using the Wall Clip Connections FX82052 Connections, -4 Models SC Fiber Connectors ShownFiber connections 10BASE-T/100BASE-TX connectionsFiber Link FX Mode Position Fiber Ports a and B Are Independent FX Mode Position FX Mode Position Fiber Ports a and B Are Independent Check power connection TroubleshootingModule Reseat module or power Supply as necessary Replace power supplyMeaning Optic Fault LED on local Section in this table Indication Fefi On local module Optical signalReplace local module By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Desired, refer to Setting Table D. Troubleshooting with Rear-Panel IndicatorsAmber If 10BASE-T operation isMeaning Possible Cause Corrective Action Duplex mode Duplex link Duplex modeRefer to Setting If half-duplex mode isGreen Port is set to If 100BASE-TX full-duplex Mode refer to SettingFull-duplex operation is not Flashing green Port is set to Normal or excessiveTable D. Troubleshooting with Rear-Panel Indicators Link/activity and speed, duplex/collision and speed SpecificationsOptic Fault optic signal/laser status per fiber port Multimode 62.5/125 μm FX82052, -2 Models Wavelength Optical MaximumSingle-Mode 9/125 μm FX82052SSTR-2Fibers Illustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsProduct Warranty and Return Information ISO9001