Pelco FX82052 manual Rear Panel, 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectors

Page 12

REAR PANEL

FX82052 REAR PANEL, -2 MODELS

Figure 4 illustrates the rear panel of the FX82052 module containing five 10BASE-T/100BASE-TX ports and two 100BASE-FX fiber ports that each accept one fiber (-2 models).

Figure 4. Rear Panel of FX82052 Module, -2 Models (SC Fiber Connectors Shown)

ìRack Power/Alarm Connector: 4-pin connector for power/alarm connection of rack- mounted module

îStand-Alone Power Connector: 2-pin connector for power connection of stand-alone module; removable mating connector with screw terminals (not shown)

ï10BASE-T/100BASE-TX Ports: 1-5,RJ-45 connectors

ñFiber Optic Ports A and B: Single-fiber ST or SC connectors (dependent on FX82052 model)

óRJ-45 10BASE-T/100BASE-TX Port Status LED, Left: Link/activity status indicator

rRJ-45 10BASE-T/100BASE-TX Port Status LED, Right: Duplex mode/collision indicator

For additional information about rear-panel connections, refer to Installation on page 14. For detailed information about the RJ-45 LEDs, refer to Troubleshooting on page 26.

12

C2607M (2/07)

Image 12
Contents Ethernet Switch Contents List of IllustrationsTX Mode Switch Settings FX Mode Switch Settings List of TablesImportant Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionPOINT-TO-POINT Application with Fiber Redundancy C2607M 2/07 Models FX82052, -2 Models Multimode ModelsSingle-Mode Models† FX82052, -4 Models Multimode ModelsPower LED Pelco badge Front Panel100BASE-FX Status LED Per fiber port a and B 10BASE-T/100BASE-TX Ports 1-5,RJ-45 connectors Rear Panel10BASE-T/100BASE-TX Ports 1-5 RJ-45 connectors FX82052 Rear PANEL, -4 ModelsInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultSetting Fiber Failover Mode Table A. TX Mode Switch SettingsFlow control default setting 10BASE-T/100BASE-TX Modes of OperationTable B. FX Mode Switch Settings Mode of OperationDefault setting Secondary fiber linkMounting Mounting the FX82052 Module Into a RackMounting the FX82052 Module Using the Wall Clip FX82052 Connections, -4 Models SC Fiber Connectors Shown Connections10BASE-T/100BASE-TX connections Fiber connectionsFiber Link FX Mode Position Fiber Ports a and B Are Independent FX Mode Position FX Mode Position Fiber Ports a and B Are Independent Troubleshooting Check power connectionModule Reseat module or power Supply as necessary Replace power supplyMeaning Indication Fefi On local module Optical signal Optic Fault LED on local Section in this tableReplace local module By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Table D. Troubleshooting with Rear-Panel Indicators Desired, refer to SettingAmber If 10BASE-T operation isMeaning Possible Cause Corrective Action Duplex mode Duplex mode Duplex linkRefer to Setting If half-duplex mode isMode refer to Setting Green Port is set to If 100BASE-TX full-duplexFull-duplex operation is not Flashing green Port is set to Normal or excessiveTable D. Troubleshooting with Rear-Panel Indicators Specifications Optic Fault optic signal/laser status per fiber portLink/activity and speed, duplex/collision and speed FX82052, -2 Models Wavelength Optical Maximum Multimode 62.5/125 μmSingle-Mode 9/125 μm FX82052SSTR-2Fibers Appendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsProduct Warranty and Return Information ISO9001