TROUBLESHOOTING (cont.)

TROUBLESHOOTING (cont.)

Screen Displayed

 NO FUNNEL PRESENTPRESS BREW NO FUNNEL PRESENT

TEMPERATURE

TOO LOW

TEMPERATURE.Troubleshooting ProceduresCHECK FUNNEL FOR FRESH COFFEE

PRESS BREW

TO BREW ANYWAY

BREW STOPPED!

FUNNEL REMOVED?

TO FINISH:

PRESS BREW

TO CANCEL

PRESS ON/OFF

Possible Cause

1.SMART FUNNEL not fully inserted into the funnel rails.

2.Not using a SMART FUNNEL, and the FUNNEL DETECT function is activated (on).

1.Water temperature in the tank does not meet the SET READY

TEMPERATURE.

1.Brew funnel was not removed after the previous brew cycle was finished.

1.Brew funnel was moved out of position after the brew cycle was started.

Troubleshooting Procedures

Position the funnel so that the sensor is directly beneath the sensor coil on the brewer.

Disable the FUNNEL DETECT func- tion.

(a)Wait for the brewer to heat to the proper temperature.

(b)Disable the BREW LOCKOUT function.

Remove funnel, check contents, and insert back into the funnel rails.

OR

Press BREW to start a brew cycle without removing the funnel.

To resume brewing, correctly posi- tion the funnel and press BREW again. The brew cycle will resume from the point it was interrupted.

OR

Press ON/OFF to terminate the cycle.

Page 42

29877-3 062005

 