Bunn S/N DUAL068000 TROUBLESHOOTING cont, Problem, Troubleshooting Procedure, Possible Cause

Models: S/N DUAL068000

1 54
Download 54 pages 17.6 Kb
Page 45
Image 45

TROUBLESHOOTING (cont.)

Problem

Possible Cause

Troubleshooting Procedure

Equipment will not operate.

1. No power or incorrect voltage.

Measure the voltage at the terminal

 

 

block and confirm that it matches

 

 

the voltage specified on the brewer

 

 

data plate within +/- 10%.

Brew cycle will not start.

1.

No water

 

2.

ON/OFF switch

3. Brew switch

Check plumbing and shut-off valves

Test the ON/OFF switch. Refer to the switch test procedures on pages 36-38.

Test the BREW switch. Refer to the switch test procedures on pages 36-38.

Automatic refill will not operate or display shows FILL TIME TOO LONG

4.Brew Valve

5.Electronic Control Board

1.No water

2.Water strainer/flow control (.750 GPM)

Test the Brew valve. Refer to Testing Individual Components.

Substitute a control board known to be in good working order.

Check plumbing and shut-off valves.

(A)Direction of flow arrow must be pointing towards direction of water flow.

(B)Remove the strainer/flow control and check for obstructions. Clear or replace.

Page 45

29877-3 062005

 

Page 45
Image 45