PROGRAMMING THE BREWER (cont.)

BREW COUNTERS (cont.)

5.When finished, press NEXT to advance counter screens until the display reads BREW COUN- TERS. Press and release NO to advance to the next function screen, or press and release either ON/OFF switch on the front switch panel to exit the BREW COUNTERS function and return to the

MAIN SCREEN.

FUNNEL DETECT (optional)

This function allows the operator to prevent the start of a brew cycle if a Smart Funnel is not positioned correctly in the funnel rails.

FUNNEL DETECT ?

NO DONE YES

P2721

Procedure to set funnel detect:

1.Press and hold the upper right hidden switch until display reads UNITS. Release the switch. Continue to press and release switch until display reads

FUNNEL DETECT.

2.NO or YES should be flashing to indicate the cur- rent setting.

4.Select YES to prevent brewing if a Smart Funnel is not correctly situated in the rails. If this function is activated and a brew cycle is attempted with the funnel not properly situated, the display will read, FUNNEL NOT IN PLACE, until one is in place.

5.Select NO to allow brewing without a Smart Fun- nel in place. This is selected when brewing with a funnel other than a Smart Funnel (a regular brew funnel).

6.When finished, press and release DONE. This will retain the changes, exit this function screen and advance to the next. Another alternative is to press either ON/OFF switch located on the front switch panel to exit the FUNNEL DETECT and return to the MAIN SCREEN.

SERVER DETECT

This function allows the operator to prevent the start of a brew cycle if a Soft Heat server is not positioned correctly on the brewer.

SEVER DETECT ?

NO DONE YES

P2721

Procedures to set server detect:

1.Press and hold the upper right hidden switch until display reads UNITS. Release the switch. Continue to press and release switch until display reads

SERVER DETECT.

2.The NO or YES flashes to indicate the current selection.

3.Select YES to prevent brewing if the Soft Heat server is not correctly positioned on the brewer beneath the funnel.

NOTE: If YES is selected and a brew cycle is attempted with a server not properly placed, the display will read

SERVER NOT IN PLACE.

4.Select NO to allow brewing without a Soft Heat server in place. This is selected when brewing into a container other than a Soft Heat Server.

5.When finished, press and release DONE. This will save the new setting, exit the function screen and advance to SERVICE TOOLS. Another alternative is to press either ON/OFF switch located on the front switch panel to exit the SERVER DETECT function and return to the MAIN SCREEN.